|
ÑÒÐÎÈÒÅËÜÍÛÅ ÍÎÐÌÛ È ÏÐÀÂÈËÀ
ÑÁÎÐÍÈÊ N 8
ÑÌÅÒÍÛÕ ÍÎÐÌ È ÐÀÑÖÅÍÎÊ ÍÀ
ÑÒÐÎÈÒÅËÜÍÛÅ ÐÀÁÎÒÛ
ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÈÐÏÈ×À È
ÁËÎÊÎÂ
ÑÍÈÏ 4.02-91
ÃÎÑÑÒÐÎÉ ÑÑÑÐ
ÌÎÑÊÂÀ 1991
ÑÒÐÎÈÒÅËÜÍÛÅ ÍÎÐÌÛ È ÏÐÀÂÈËÀ
ÑÁÎÐÍÈÊ N 8
ÑÌÅÒÍÛÕ ÍÎÐÌ È ÐÀÑÖÅÍÎÊ ÍÀ
ÑÒÐÎÈÒÅËÜÍÛÅ ÐÀÁÎÒÛ
ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÈÐÏÈ×À È
ÁËÎÊÎÂ
ÑÍÈÏ 4.02-91
ÓÒÂÅÐÆÄÅÍ
ÏÎÑÒÀÍÎÂËÅÍÈÅÌ
ÃÎÑÑÒÐÎß ÑÑÑÐ
ÎÒ 29 ÄÅÊÀÁÐß 1990 Ã. N 115
ÃÎÑÑÒÐÎÉ ÑÑÑÐ
ÌÎÑÊÂÀ 1991
ÑÍÈÏ 4.02-91 ÑÁÎÐÍÈÊ ÑÌÅÒÍÛÕ ÍÎÐÌ È ÐÀÑÖÅÍÎÊ ÍÀ ÑÒÐÎÈÒÅËÜÍÛÅ ÐÀÁÎÒÛ.
ÑÁÎÐÍÈÊ 8. ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÈÐÏÈ×À È ÁËÎÊÎÂ. - ÃÎÑÑÒÐÎÉ ÑÑÑÐ - Ì: ÑÒÐÎÉÈÇÄÀÒ,
1991 - 10Ñ
ÐÀÇÐÀÁÎÒÀÍ ÈÍÑÒÈÒÓÒÎÌ ÌÍÈÈÒÝÏ ÌÎÑÑÒÐÎÉÊÎÌÈÒÅÒÀ ÌÎÑÃÎÐÈÑÏÎËÊÎÌÀ È ÐÀÑÑÌÎÒÐÅÍ
ÓÏÐÀÂËÅÍÈÅÌ ÖÅÍÎÎÁÐÀÇÎÂÀÍÈß È ÑÌÅÒ Â ÑÒÐÎÈÒÅËÜÑÒÂÅ ÃÎÑÑÒÐÎß ÑÑÑÐ.
ÐÅÄÀÊÒÎÐÛ: ÈÍÆÅÍÅÐÛ Â.Â.ÑÅÌÛÊÈÍ, Ë.À.ÊÓËÈÊÎÂÀ (ÃÎÑÑÒÐÎÉ ÑÑÑÐ), Ì.Â.ÀÏÓÕÒÈÍ,
Î.Å.ÀÒÐÎÕÈÍÀ, Ë.Â.ÁÎÃÄÀÍÎÂÀ (ÖÍÈÈÝÓÑ ÃÎÑÑÒÐÎß ÑÑÑÐ), Í.À.ÄÛÌÎÂÀ (ÌÍÈÈÒÝÏ)
ÑÒÐÎÉÈÇÄÀÒ 1991
------------------------------------------------------------------------------------------------------
ÃÎÑÓÄÀÐÑÒÂÅÍÍÛÉ ÑÒÐÎÈÒÅËÜÍÛÉ ¦ ÑÒÐÎÈÒÅËÜÍÛÅ ÍÎÐÌÛ È ÏÐÀÂÈËÀ ¦ ÑÍÈÏ 4.02-91 ¦
ÊÎÌÈÒÅÒ ÑÑÑÐ ¦---------------------------------¦---------------------------------¦
(ÃÎÑÑÒÐÎÉ ÑÑÑÐ) ¦ ÑÁÎÐÍÈÊ ÑÌÅÒÍÛÕ ÍÎÐÌ È ÐÀÑÖÅÍÎÊ ¦ ÂÇÀÌÅÍ ÑÁÎÐÍÈÊÎÂ ÝËÅÌÅÍÒÍÛÕ ¦
¦ ÍÀ ÑÒÐÎÈÒÅËÜÍÛÅ ÐÀÁÎÒÛ ¦ ÑÌÅÒÍÛÕ ÍÎÐÌ È ÅÄÈÍÛÕ ÐÀÉÎÍÍÛÕ ¦
¦ ÑÁÎÐÍÈÊ 8. ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ¦ ÅÄÈÍÈ×ÍÛÕ ÐÀÑÖÅÍÎÊ ÍÀ ÑÒÐÎÈÒÅËÜ-¦
¦ ÊÈÐÏÈ×À È ÁËÎÊΠ¦ ÍÛÅ ÊÎÍÑÒÐÓÊÖÈÈ È ÐÀÁÎÒÛ ¦
¦ ¦ (ÅÐÅÐ-84) ÑÁÎÐÍÈÊ N 8 ¦
¦ ¦"ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÈÐÏÈ×À È ÁËÎÊÎÂ"¦
------------------------------------------------------------------------------------------------------
ÒÅÕÍÈ×ÅÑÊÀß ×ÀÑÒÜ
1. ÎÁÙÈÅ ÓÊÀÇÀÍÈß ÐÀÇÌÅÐÎÂ ÐÀÑÕÎÄ ÌÀÒÅÐÈÀËÎÂ ÊÎÐÐÅÊÒÈÐÓÅÒÑß ÏÎ
ÌÅÑÒÍÛÌ ÏÐÎÈÇÂÎÄÑÒÂÅÍÍÛÌ ÍÎÐÌÀÌ È ÐÀÑÖÅÍÊÀÌ.
1.1. ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÍÀÑÒÎßÙÅÃÎ ÑÁÎÐÍÈÊÀ ÓÑÒÀÍÎÂÊÀ ÄÅÐÅÂßÍÍÛÕ ÏÐÎÁÎÊ ÍÎÐÌÀÌÈ È ÐÀÑ-
ÏÐÅÄÓÑÌÀÒÐÈÂÀÞÒ ÐÀÁÎÒÛ ÏÎ ÂÎÇÂÅÄÅÍÈÞ ÊÀÌÅÍÍÛÕ ÖÅÍÊÀÌÈ Ó×ÒÅÍÀ.
ÊÎÍÑÒÐÓÊÖÈÉ ÏÐÎÌÛØËÅÍÍÛÕ, ÆÈËÛÕ, ÎÁÙÅÑÒÂÅÍÍÛÕ È 1.4. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÒÀÁË.2 ÃÐ.1,2,4-9
ÑÅËÜÑÊÎÕÎÇßÉÑÒÂÅÍÍÛÕ ÇÄÀÍÈÉ. ÊÐÎÌÅ ÒÎÃÎ,  ÑÁÎÐ- Ó×ÒÅÍÀ ÃÎÐÈÇÎÍÒÀËÜÍÀß ÈÇÎËßÖÈß ÔÓÍÄÀÌÅÍÒΠÈ
ÍÈÊ ÂÊËÞ×ÅÍÛ ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÍÀ ÐÀÁÎÒÛ ÏÎ ÓÑÒÀ- ÑÒÅÍ. ÑÒÎÈÌÎÑÒÜ ÃÎÐÈÇÎÍÒÀËÜÍÎÉ ÈÇÎËßÖÈÈ ÌÀÑÑÈÂÎÂ
ÍÎÂÊÅ ÈÍÂÅÍÒÀÐÍÛÕ ËÅÑÎÂ, ÏÎ ÃÈÄÐÎÈÇÎËßÖÈÈ ÔÓÍÄÀ- ÑËÅÄÓÅÒ ÎÏÐÅÄÅËßÒÜ ÏÎ ÍÎÐÌÀÌ È ÐÀÑÖÅÍÊÀÌ ÒÀÁË. 4
ÌÅÍÒÎÂ È ÑÒÅÍ ÇÄÀÍÈÉ, ÏÎ ÓÑÒÐÎÉÑÒÂÓ ÌÓÑÎÐÎÏÐÎÂÎ- ÃÐ.1-3.
ÄÎÂ, ÓÑÒÀÍÎÂÊÅ ÏÅÐÅÃÎÐÎÄÎÊ ÈÇ ÏËÈÒ È ÑÒÅÊËßÍÍÛÕ ÓÑÒÐÎÉÑÒÂÎ ÈÇÎËßÖÈÈ ÏÎ ÑÒÅÍÀÌ ÂÛØÅ ÓÐÎÂÍß
ÁËÎÊÎÂ, ÊËÀÄÊÅ ÏÅ×ÅÉ È Î×ÀÃΠÎÒÎÏÈÒÅËÜÍÛÕ. ÇÅÌËÈ ÑËÅÄÓÅÒ ÎÏÐÅÄÅËßÒÜ ÄÎÏÎËÍÈÒÅËÜÍÎ ÏÎ ÍÎÐÌÀÌ
1.2. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÒÀÁË.6 (ÃÐ.1-6) È È ÐÀÑÖÅÍÊÀÌ ÒÀÁË.4 ÃÐ.1-3.
ÒÀÁË.10,13 ÏÐÅÄÓÑÌÎÒÐÅÍÀ ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ ÑÒÅÍ ÈÇ 1.5. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÒÀÁË.4 ÃÐ.5,6 ÏÐÅ-
ÊÈÐÏÈ×À È ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ ÄÓÑÌÎÒÐÅÍÎ ÓÑÒÐÎÉÑÒÂÎ ÁÎÊÎÂÎÉ ÈÇÎËßÖÈÈ ÏÎ ÊÈÐ-
ÊËÀÄÎ×ÍÛÕ Â ÇÀÂÈÑÈÌÎÑÒÈ ÎÒ ÈÕ ÑËÎÆÍÎÑÒÈ Â ÑÎÎÒ- ÏÈ×ÍÛÌ, ÁÅÒÎÍÍÛÌ È ÁÓÒÎÂÛÌ ÑÒÅÍÀÌ, ÂÛÐÎÂÍÅÍÍÛÌ
ÂÅÒÑÒÂÈÈ ÑÎ ÑËÅÄÓÞÙÅÉ ÊËÀÑÑÈÔÈÊÀÖÈÅÉ: ÐÀÑÒÂÎÐÎÌ.
- ÏÐÎÑÒÛÅ ÑÒÅÍÛ - Ñ ÓÑËÎÆÍÅÍÍÛÌÈ ×ÀÑÒßÌÈ, ÓÑÒÐÎÉÑÒÂÎ ÇÀÙÈÒÍÎÉ ÑÒÅÍÊÈ È ÄÐÓÃÈÕ ÇÀÙÈÒÍÛÕ
ÇÀÍÈÌÀÞÙÈÌÈ ÏËÎÙÀÄÜ, ÍÅ ÏÐÅÂÛØÀÞÙÓÞ 10 % ÏËÎÙÀÄÈ ÊÎÍÑÒÐÓÊÖÈÉ ÏÐÈ ÎÊËÅÅ×ÍÎÉ ÈÇÎËßÖÈÈ ÍÎÐÌÀÌÈ È
ËÈÖÅÂÎÉ ÑÒÎÐÎÍÛ ÍÀÐÓÆÍÛÕ ÑÒÅÍ; ÐÀÑÖÅÍÊÀÌÈ ÒÀÁË.4 ÃÐ.5,6 ÍÅ ÏÐÅÄÓÑÌÎÒÐÅÍÎ. ÑÒÎÈ-
- ÑÒÅÍÛ ÑÐÅÄÍÅÉ ÑËÎÆÍÎÑÒÈ - Ñ ÓÑËÎÆÍÅÍÍÛÌÈ ÌÎÑÒÜ ÝÒÈÕ ÐÀÁÎÒ Â ÍÅÎÁÕÎÄÈÌÛÕ ÑËÓ×ÀßÕ ÎÏÐÅÄÅËß-
×ÀÑÒßÌÈ, ÇÀÍÈÌÀÞÙÈÌÈ ÏËÎÙÀÄÜ, ÍÅ ÏÐÅÂÛØÀÞÙÓÞ 20% ÅÒÑß ÄÎÏÎËÍÈÒÅËÜÍÎ. ÏÐÈ ÓÑÒÐÎÉÑÒÂÅ ÁÎÊÎÂÎÉ ÈÇÎ-
ÏËÎÙÀÄÈ ËÈÖÅÂÎÉ ÑÒÎÐÎÍÛ ÍÀÐÓÆÍÛÕ ÑÒÅÍ; ËßÖÈÈ ÏÎ ÍÅÂÛÐÎÂÍÅÍÍÛÌ ÁÓÒÎÂÛÌ ÑÒÅÍÀÌ ÑÒÎÈÌÎÑÒÜ
- ÑËÎÆÍÛÅ ÑÒÅÍÛ - Ñ ÓÑËÎÆÍÅÍÍÛÌÈ ×ÀÑÒßÌÈ, ×ÀÑÒÈ×ÍÎÉ ÏÐÈÊÎËÊÈ ÊËÀÄÊÈ È ÂÛÐÀÂÍÈÂÀÍÈß ÏÎÂÅÐÕ-
ÇÀÍÈÌÀÞÙÈÌÈ ÏËÎÙÀÄÜ, ÍÅ ÏÐÅÂÛØÀÞÙÓÞ 40 % ÏËÎÙÀÄÈ ÍÎÑÒÈ ÊËÀÄÊÈ ÐÀÑÒÂÎÐÎÌ ÎÏÐÅÄÅËßÅÒÑß ÏÎ ÍÎÐÌÀÌ È
ËÈÖÅÂÎÉ ÑÒÎÐÎÍÛ ÍÀÐÓÆÍÛÕ ÑÒÅÍ; ÐÀÑÖÅÍÊÀÌ ÒÀÁË.4 ÃÐ.8.
- ÑÒÅÍÛ Ñ ÓÑËÎÆÍÅÍÍÛÌÈ ×ÀÑÒßÌÈ, ÇÀÍÈÌÀÞÙÈÌÈ 1.6.  ÍÎÐÌÀÕ È ÐÀÑÖÅÍÊÀÕ ÒÀÁË.13,15,19,20,
ÁÎËÅÅ 40 % ÏËÎÙÀÄÈ ËÈÖÅÂÎÉ ÑÒÎÐÎÍÛ ÍÀÐÓÆÍÛÕ 22 ÃÐ.1-10, 23 ÃÐ.1-6,9-14 Ó×ÒÅÍÀ ÊËÀÄÊÀ ÎÁÛ×ÍÛÕ
ÑÒÅÍ, ÎÒÍÎÑßÒÑß Ê ÎÑÎÁÎ ÑËÎÆÍÛÌ ÑÒÅÍÀÌ È ÍÎÐÌÀÌÈ ÏÎßÑÊΠÊÀÐÍÈÇÎÂ È ÏÎÄÎÁÍÛÕ ÝËÅÌÅÍÒΠÔÀÑÀÄÀ ÈÇ
È ÐÀÑÖÅÍÊÀÌÈ ÍÀÑÒÎßÙÅÃÎ ÑÁÎÐÍÈÊÀ ÍÅ ÏÐÅÄÓÑÌÎÒÐÅ- ÌÀÒÅÐÈÀËÎÂ, ÏÐÅÄÓÑÌÎÒÐÅÍÍÛÕ ÝÒÈÌÈ ÍÎÐÌÀÌÈ È ÐÀÑ-
ÍÛ. ÖÅÍÊÀÌÈ. ÊËÀÄÊÓ ÓÊÀÇÀÍÍÛÕ ÝËÅÌÅÍÒÎÂ ÔÀÑÀÄÀ Ñ ÎÁ-
ÑËÎÆÍÎÑÒÜ ÍÀÐÓÆÍÛÕ ÑÒÅÍ ÓÑÒÀÍÀÂËÈÂÀÅÒÑß Â ËÈÖÎÂÊÎÉ ÊÈÐÏÈ×ÎÌ È ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ËÈÖÅ-
ÂÈÄÅ ÂÛÐÀÆÅÍÍÎÃÎ Â ÏÐÎÖÅÍÒÀÕ ÎÒÍÎØÅÍÈß ÏËÎÙÀÄÈ, ÂÛÌÈ ÏÐÎÔÈËÜÍÛÌÈ ÑËÅÄÓÅÒ ÍÎÐÌÈÐÎÂÀÒÜ È ÐÀÑÖÅÍÈ-
ÇÀÍÈÌÀÅÌÎÉ ÓÑËÎÆÍÅÍÍÛÌÈ ×ÀÑÒßÌÈ ÊËÀÄÊÈ (ÍÀ ÎÁÅÈÕ ÂÀÒÜ ÏÎ ÒÀÁË.16,17.
ÑÒÎÐÎÍÀÕ ÂÑÅÕ ÍÀÐÓÆÍÛÕ ÑÒÅÍ), Ê ÎÁÙÅÉ ÏËÎÙÀÄÈ 1.7. Â ÍÎÐÌÀÕ È ÐÀÑÖÅÍÊÀÕ ÒÀÁËÈÖ 6 (ÃÐ.1-6),
ËÈÖÅÂÎÉ ÑÒÎÐÎÍÛ ÍÀÐÓÆÍÛÕ ÑÒÅÍ ÁÅÇ ÂÛ×ÅÒÀ ÏÐÎÅ- 10,13 ÏÐÅÄÓÑÌÎÒÐÅÍÀ ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ ÑÒÅÍ ÁÅÇ ÎÁ-
ÌÎÂ. ËÈÖÎÂÊÈ, 15,18,22 (ÃÐ.5-10), 23 (ÃÐ.9,10) - Ñ
ÏÐÈ ÝÒÎÌ Ê ÓÑËÎÆÍÅÍÍÛÌ ×ÀÑÒßÌ ÊËÀÄÊÈ ÎÒÍÎ- ÎÁËÈÖÎÂÊÎÉ, 20 - Ñ ÂÎÇÄÓØÍÎÉ ÏÐÎÑËÎÉÊÎÉ È ÓÒÅÏ-
ÑßÒÑß ÂÛÏÎËÍßÅÌÛÅ ÈÇ ÊÈÐÏÈ×À È ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑ- ËÅÍÈÅÌ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÌÈ ÏËÈÒÀÌÈ, ÊËÀÄÊÓ ÂÍÓÒ-
ÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ ÊÀÐÍÈÇÛ, ÏÎßÑÊÈ, ÑÀÍÄÐÈÊÈ, ÐÅÍÍÈÕ ÑÒÅÍ ÈÇ ÊÈÐÏÈ×À  ÝÒÈÕ ÑËÓ×ÀßÕ ÑËÅÄÓÅÒ
ÐÓÑÒÛ, ÊÎÍÒÐÔÎÐÑÛ, ÏÈËßÑÒÐÛ, ÏÎËÓÊÎËÎÍÍÛ, ÝÐÊÅ- ÍÎÐÌÈÐÎÂÀÒÜ È ÐÀÑÖÅÍÈÂÀÒÜ ÏÎ ÒÀÁË. 6 (ÃÐ.7,8), À
ÐÛ, ËÎÄÆÈÈ, ÎÁÐÀÌËÅÍÈÅ ÏÐÎÅÌΠÊÐÈÂÎËÈÍÅÉÍÎÃÎ ÈÇ ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ, ÊËÀÄÎ×ÍÛÕ
Î×ÅÐÒÀÍÈß, À ÒÀÊÆÅ ÓÑÒÐÎÉÑÒÂÎ ÍÈØ. - ÏÎ ÒÀÁË.13 (ÃÐ. 1,2) Ñ ÏÐÈÌÅÍÅÍÈÅÌ ÐÀÑÒÂÎÐÀ
1.3. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÍÀÑÒÎßÙÅÃÎ ÑÁÎÐÍÈ- ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÎÃÎ 50 ÂÌÅÑÒÎ 25.
ÊÀ ÏÐÅÄÓÑÌÎÒÐÅÍÎ ÏÐÈÌÅÍÅÍÈÅ ÊÈÐÏÈ×À ÊÅÐÀÌÈ×ÅÑÊÎ- 1.8.  ÒÀÁËÈÖÀÕ 19,20 ÏÐÅÄÓÑÌÎÒÐÅÍÛ ÊÎÌÏËÅÊ-
ÃÎ, ÏÓÑÒÎÒÅËÎÃÎ, ÑÈËÈÊÀÒÍÎÃÎ ÊËÀÄÎ×ÍÎÃÎ ÈËÈ ËÈ- ÑÍÛÅ ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÍÀ ÊËÀÄÊÓ ÍÀÐÓÆÍÛÕ ÊÈÐÏÈ×-
ÖÅÂÎÃÎ ÐÀÇÌÅÐÎÌ 250Õ120Õ65 ÌÌ; ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑ- ÍÛÕ ÑÒÅÍ ÎÁËÅÃ×ÅÍÍÎÉ ÊÎÍÑÒÐÓÊÖÈÈ È ÂÍÓÒÐÅÍÍÈÕ
ÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ (ÊËÀÄÎ×ÍÛÕ ËÈÖÅÂÛÕ) ÐÀÇÌÅÐÎÌ ÊÈÐÏÈ×ÍÛÕ ÑÒÅÍ ÊÀÊ ÎÁËÅÃ×ÅÍÍÎÉ, ÒÀÊ È ÎÁÛ×ÍÎÉ
250Õ120Õ138 ÌÌ. ÊÎÍÑÒÐÓÊÖÈÈ.
ÏÐÈ ÏÐÈÌÅÍÅÍÈÈ ÊÈÐÏÈ×À ÈËÈ ÊÀÌÍÅÉ ÄÐÓÃÈÕ 1.9. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÒÀÁË. 22 ÃÐ.1-10
------------------------------------------------------------------------------------------------------
ÂÍÅÑÅÍ ÓÏÐÀÂËÅÍÈÅÌ ¦ ÓÒÂÅÐÆÄÅÍ ÏÎÑÒÀÍÎÂËÅÍÈÅÌ ¦ ÑÐÎÊ ÂÂÅÄÅÍÈß Â ÄÅÉÑÒÂÈÅ ¦
ÖÅÍÎÎÁÐÀÇÎÂÀÍÈß È ÑÌÅÒ Â ¦ ÃÎÑÓÄÀÐÑÒÂÅÍÍÎÃÎ ÑÒÐÎÈÒÅËÜÍÎÃÎ ¦ 1 ßÍÂÀÐß 1991 Ã. ¦
ÑÒÐÎÈÒÅËÜÑÒÂÅ ÃÎÑÑÒÐÎß ÑÑÑÐ ¦ ÊÎÌÈÒÅÒÀ ÑÑÑÐ ¦ ¦
¦ ÎÒ 29 ÄÅÊÀÁÐß 1990 Ã. N 115 ¦ ¦
------------------------------------------------------------------------------------------------------
ÏÐÅÄÓÑÌÎÒÐÅÍÀ ÊËÀÄÊÀ ÑÒÅÍ ÊÀÊ ÈÇ ÑÏËÎØÍÛÕ, ÒÀÊ È ÓÑÒÐÎÉÑÒÂÎ, ÐÀÇÁÎÐÊÓ È ÀÌÎÐÒÈÇÀÖÈÞ ÈÍÂÅÍÒÀÐÍÛÕ
ÈÇ ÏÓÑÒÎÒÅËÛÕ ËÅÃÊÎÁÅÒÎÍÍÛÕ ÊÀÌÍÅÉ ÁÅÇ ÇÀÑÛÏÊÈ ËÅÑÎÂ, È ÏÐÅÄÓÑÌÀÒÐÈÂÀÞÒ ÂÛÑÎÒÓ ÍÀÐÓÆÍÛÕ ËÅÑÎÂ:
ÏÓÑÒÎÒ.  ÑËÓ×ÀÅ ÍÅÎÁÕÎÄÈÌÎÑÒÈ ÇÀÑÛÏÊÀ ÏÓÑÒÎÒ Â ÒÐÓÁ×ÀÒÛÕ ÄËß ÊËÀÄÊÈ È ÎÁËÈÖÎÂÊÈ - ÄÎ 40 Ì,
ÊÀÌÍßÕ ÏÐÈÍÈÌÀÅÒÑß ÏÎ ÍÎÐÌÅ È ÐÀÑÖÅÍÊÅ ÒÀÁË. 22 ÒÐÓÁ×ÀÒÛÕ ÄËß ÏÐÎ×ÈÕ ÎÒÄÅËÎ×ÍÛÕ ÐÀÁÎÒ - 60 Ì,
ÃÐ.11. ÏÎÄÂÅÑÍÛÕ - ÄÎ 18 Ì.
1.10. ÏÐÈ ÊËÀÄÊÅ ÑÒÅÍ, ÏÐÅÄÓÑÌÎÒÐÅÍÍÛÕ ÒÀÁË. 1.19. ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÒÀÁË.35 (ÃÐ.4,5), 36
19-23 ÓÑÒÐÎÉÑÒÂÎ ÖÎÊÎËß, ÏÎßÑÊÎÂ È ÏÎÄÎÁÍÛÕ ÝËÅ- (ÃÐ.2) ÏÐÈÌÅÍßÞÒÑß ÒÀÊÆÅ È ÏÐÈ ÓÂÅËÈ×ÅÍÈÈ ÂÛÑÎÒÛ
ÌÅÍÒÎÂ, ÂÛÏÎËÍßÅÌÛÕ ÑÏËÎØÍÎÉ ÊËÀÄÊÎÉ ÈÇ ÊÈÐÏÈ×À, ÏÎÌÅÙÅÍÈß ÍÀ ÍÅÏÎËÍÛÅ 4 Ì.
ÑËÅÄÓÅÒ ÍÎÐÌÈÐÎÂÀÒÜ È ÐÀÑÖÅÍÈÂÀÒÜ ÏÎ ÒÀÁË.6 (ÃÐ. 1.20. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÒÀÁË.39 ÍÅ Ó×ÈÒÛ-
1,2) ÊÀÐÍÈÇÎÂ È ÄÐÓÃÈÕ ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ ÈÇ ÂÀÅÒÑß ÑÒÎÈÌÎÑÒÜ ÏÐÈÁÎÐΠÄËß ÏÅ×ÅÉ È Î×ÀÃÎÂ.
ÊÈÐÏÈ×À - ÏÎ ÒÀÁË. 8 (ÃÐÀÔÀ 7,8). 1.21. ÍÎÐÌÀ È ÐÀÑÖÅÍÊÀ ÒÀÁË. 40 ÍÅ Ó×ÈÒÛÂÀÅÒ
1.11.  ÍÎÐÌÀÕ È ÐÀÑÖÅÍÊÀÕ ÒÀÁË. 23 ÏÐÅÄÓ- ÑÒÎÈÌÎÑÒÜ ÏËÈÒ ÏÅÐÅÍÎÑÍÛÕ ÌÅÒÀËËÈ×ÅÑÊÈÕ.
ÑÌÀÒÐÈÂÀÅÒÑß ÑËÅÄÓÞÙÀß ÊËÀÑÑÈÔÈÊÀÖÈß ÊËÀÄÊÈ ÑÒÅÍ 1.22. ÑÒÎÈÌÎÑÒÍÛÅ ÏÎÊÀÇÀÒÅËÈ Â ÒÀÁËÈÖÀÕ ÄÀÍÛ
ÈÇ ÏÐÈÐÎÄÍÛÕ ÊÀÌÍÅÉ: ÄËß ÏÅÐÂÎÃÎ ÒÅÐÐÈÒÎÐÈÀËÜÍÎÃÎ ÐÀÉÎÍÀ, ÏÐÈÍßÒÎÃÎ
À) ÎÁÛ×ÍÀß - ÏÎÄ ØÒÓÊÀÒÓÐÊÓ; ÇÀ ÁÀÇÈÑÍÛÉ.
Á) ÐßÄÎÂÀß - ÁÅÇ ÄÎÏÎËÍÈÒÅËÜÍÎÉ ÎÁÐÀÁÎÒÊÈ ÏÐÈ ÈÑÏÎËÜÇÎÂÀÍÈÈ ÝÒÈÕ ÏÎÊÀÇÀÒÅËÅÉ Â ÄÐÓÃÈÕ
ËÈÖÅÂÎÉ ÏÎÂÅÐÕÍÎÑÒÈ ÊÀÌÍß Ñ ÏÎÄÁÎÐÎÌ ÊÀÌÍÅÉ È ÒÅÐÐÈÒÎÐÈÀËÜÍÛÕ ÐÀÉÎÍÀÕ ÑËÅÄÓÅÒ ÏÐÈÌÅÍßÒÜ ÒÅÐÐÈ-
ÏÎÄÒÅÑÊÎÉ ÏÎ ÂÛÑÎÒÅ ÐßÄÀ; ÒÎÐÈÀËÜÍÛÅ ÊÎÝÔÔÈÖÈÅÍÒÛ, ÓÊÀÇÀÍÍÛÅ Â ÐÀÇÄÅËÅ 3
Â) ×ÈÑÒÀß - Ñ ÐÀÑØÈÂÊÎÉ ØÂΠ(ÈÇ ÊÀÌÍÅÉ ×ÈÑ- ÒÅÕÍÈ×ÅÑÊÎÉ ×ÀÑÒÈ ÍÀÑÒÎßÙÅÃÎ ÑÁÎÐÍÈÊÀ È Â ÎÁÙÈÕ
ÒÎÉ ÒÅÑÊÈ ÈËÈ ÏÈËÅÍÛÕ), Ñ ÎÒÄÅËÊÎÉ ÍÀÐÓÆÍÎÃÎ ÏÎËÎÆÅÍÈßÕ ÏÎ ÏÐÈÌÅÍÅÍÈÞ ÑÍÈÐ ÍÀ ÑÒÐÎÈÒÅËÜÍÛÅ
ÂÅÐÑÒÎÂÎÃÎ ÊÀÌÍß ÏÎÄ ÒÅÐÊÓ. ÐÀÁÎÒÛ.
1.12. Â ÍÎÐÌÀÕ È ÐÀÑÖÅÍÊÀÕ ÏÐÅÄÓÑÌÎÒÐÅÍÀ
ÐÀÑØÈÂÊÀ ØÂÎÂ Ñ ËÈÖÅÂÎÉ ÑÒÎÐÎÍÛ ÍÀÐÓÆÍÛÕ ÑÒÅÍ.  2. ÏÐÀÂÈËÀ ÈÑ×ÈÑËÅÍÈß ÎÁÚÅÌΠÐÀÁÎÒ
ÑËÓ×ÀÅ, ÅÑËÈ ÏÐÎÅÊÒÎÌ ÏÐÅÄÓÑÌÎÒÐÅÍÀ ÐÀÑØÈÂÊÀ
ØÂÎÂ Ñ ÂÍÓÒÐÅÍÍÅÉ ÑÒÎÐÎÍÛ ÈËÈ ÏÐÈ ÊËÀÄÊÅ ÏÎÄ 2.1. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÁÓÒÎÂÎÉ ÊËÀÄÊÅ ÑÒÅÍ Ñ
ØÒÓÊÀÒÓÐÊÓ, ÎÁËÈÖÎÂÊÓ, ÓÌÅÍÜØÅÍÈÅ ÈËÈ ÓÂÅËÈ×ÅÍÈÅ ÎÁËÈÖÎÂÊÎÉ ÊÈÐÏÈ×ÎÌ ÑËÅÄÓÅÒ ÈÑ×ÈÑËßÒÜ Ñ Ó×ÅÒÎÌ
ÇÀÒÐÀÒ ÒÐÓÄÀ È ÇÀÐÀÁÎÒÍÎÉ ÏËÀÒÛ ÑËÅÄÓÅÒ ÏÐÈÍÈ- ÎÁËÈÖÎÂÊÈ.
ÌÀÒÜ ÄÎÏÎËÍÈÒÅËÜÍÎ ÏÎ ÒÀÁËÈÖÅ 11 (ÃÐÀÔÛ 1,2). 2.2. ÃÎÐÈÇÎÍÒÀËÜÍÀß ÈÇÎËßÖÈß ÁÓÒÎÂÛÕ ÔÓÍÄÀ-
1.13. ÏÐÈ ÀÐÌÈÐÎÂÀÍÈÈ ÊËÀÄÊÈ (ÏÅÐÅÌÛ×ÅÊ, ÌÅÍÒÎÂ È ÑÒÅÍ ÏÎÄÂÀËΠ(ÊÐÎÌÅ ÌÀÑÑÈÂÎÂ) ÂÊËÞ×ÅÍÀ
ÏÐÎÑÒÅÍÊÎÂ, ÑÂßÇÅÉ È Ò. Ï.) ÏÐÈÌÅÍßÒÜ ÍÎÐÌÛ È Â ÍÎÐÌÛ ÒÀÁË.2, ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÃÈÄÐÎÈÇÎËßÖÈÈ ÁÓ-
ÐÀÑÖÅÍÊÈ ÒÀÁË.12 (ÃÐ.1). ÒÎÂÛÕ ÌÀÑÑÈÂΠÍÀÄËÅÆÈÒ ÈÑ×ÈÑËßÒÜ ÎÒÄÅËÜÍÎ ÏÎ
1.14. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÏÐÅÄÓÑÌÎÒÐÅÍÀ ÓÑ- ÏËÎÙÀÄÈ ÈÇÎËÈÐÓÅÌÎÉ ÏÎÂÅÐÕÍÎÑÒÈ.
ÒÀÍÎÂÊÀ, ÏÅÐÅÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÏÎÄÌÎÑÒÅÉ ÄËß ÅÑËÈ ÏÐÎÅÊÒÎÌ ÏÐÅÄÓÑÌÎÒÐÅÍÎ ÓÑÒÐÎÉÑÒÂÎ ÈÇÎ-
ÊËÀÄÊÈ ÑÒÅÍ ÂÛÑÎÒÎÉ ÄÎ 4 Ì, ÏÐÈ ÊËÀÄÊÅ ÎÒÄÅËÜÍÎ ËßÖÈÈ ÄÂÀÆÄÛ - ÏÎ ÔÓÍÄÀÌÅÍÒÀÌ È ÏÎ ÑÒÅÍÀÌ ÂÛØÅ
ÑÒÎßÙÈÕ ÑÒÅÍ, ÇÀÏÎËÍÅÍÈÉ ÊÀÐÊÀÑÎÂ È ÔÀÕÂÅÐÊÎÂ È ÓÐÎÂÍß ÇÅÌËÈ, ÂÒÎÐÎÉ ÑËÎÉ ÈÇÎËßÖÈÈ ÑËÅÄÓÅÒ Ó×È-
ÊËÀÄÊÅ ÏÎÄÏÎÐÍÛÕ ÑÒÅÍ ÂÛÑÎÒÎÉ ÁÎËÅÅ 4 Ì, À ÒÀÊÆÅ ÒÛÂÀÒÜ ÄÎÏÎËÍÈÒÅËÜÍÎ.
ÑÒÅÍ È ÏÅÐÅÃÎÐÎÄÎÊ ÇÄÀÍÈÉ Ñ ÝÒÀÆÀÌÈ ÂÛÑÎÒÎÉ ÁÎ- 2.3. ÎÁÚÅÌ ÊËÀÄÊÈ ÑÒÅÍ ÍÀÄËÅÆÈÒ ÈÑ×ÈÑËßÒÜ ÇÀ
ËÅÅ 4 Ì, ÓÑÒÐÎÉÑÒÂÎ ËÅÑΠÑËÅÄÓÅÒ ÍÎÐÌÈÐÎÂÀÒÜ È ÂÛ×ÅÒÎÌ ÏÐÎÅÌΠÏÎ ÍÀÐÓÆÍÎÌÓ ÎÁÂÎÄÓ ÊÎÐÎÁÎÊ. ÏÐÈ
ÐÀÑÖÅÍÈÂÀÒÜ ÄÎÏÎËÍÈÒÅËÜÍÎ ÏÎ ÒÀÁËÈÖÅ 35, 36. ÍÀËÈ×ÈÈ Â ÏÐÎÅÌÅ ÄÂÓÕ ÊÎÐÎÁÎÊ ÏËÎÙÀÄÜ ÏÐÎÅÌÀ ÈÑ-
1.15. ÍÎÐÌÀÌÈ È ÐÀÑÖÅÍÊÀÌÈ ÏÐÅÄÓÑÌÀÒÐÈÂÀÞÒÑß ×ÈÑËßÒÜ ÏÎ ÎÁÂÎÄÓ ÍÀÐÓÆÍÎÉ ÊÎÐÎÁÊÈ.
ÌÀÐÊÈ ÐÀÑÒÂÎÐÎÂ ÄËß ÇÄÀÍÈÉ ÂÛÑÎÒÎÉ ÄÎ 9 ÝÒÀÆÅÉ, 2.4. ÎÁÚÅÌ ÊËÀÄÊÈ ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ (ÏÈ-
ÄËß ÇÄÀÍÈÉ ÁÎËÅÅ 9 ÝÒÀÆÅÉ Â ÑÎÎÒÂÅÒÑÒÂÓÞÙÈÕ ÍÎÐ- ËßÑÒÐÛ, ÏÎËÓÊÎËÎÍÍÛ, ÊÀÐÍÈÇÛ, ÏÀÐÀÏÅÒÛ, ÝÐÊÅÐÛ,
ÌÀÕ ÌÀÐÊÓ ÐÀÑÒÎÂÎÐÀ ÑËÅÄÓÅÒ ÏÐÈÍÈÌÀÒÜ 50 ÂÌÅÑÒÎ ËÎÄÆÈÈ, ÏÎßÑÊÈ È Ò. Ï.), ÂÛÏÎËÍßÅÌÛÕ ÈÇ ÌÀÒÅÐÈÀ-
25 È 75 ÂÌÅÑÒÎ 50. ËÀ, ÏÐÅÄÓÑÌÎÒÐÅÍÍÎÃÎ ÍÎÐÌÀÌÈ, ÑËÅÄÓÅÒ ÂÊËÞ×ÀÒÜ Â
1.16. Â ÍÎÐÌÀÕ È ÐÀÑÖÅÍÊÀÕ ÍÀÑÒÎßÙÅÃÎ ÑÁÎÐ- ÎÁÙÈÉ ÎÁÚÅÌ ÑÒÅÍ.
ÍÈÊÀ ÏÐÅÄÓÑÌÎÒÐÅÍÀ ÊËÀÄÊÀ Ñ ÒÎËÙÈÍÎÉ ØÂÎÂ, ÑÎÃ- ÌÅËÊÈÅ ÀÐÕÈÒÅÊÒÓÐÍÛÅ ÄÅÒÀËÈ (ÑÀÍÄÐÈÊÈ, ÏÎßÑ-
ËÀÑÍÎ ÃËÀÂÅ ÑÍÈÏ 3-03.01-87 Ã. Ï. 2.20. ÊÈ È Ò.Ï.) ÂÛÑÎÒÎÉ ÄÎ 25 ÑÌ ÍÎÐÌÀÌÈ Ó×ÒÅÍÛ È Â
ÏÐÈ ÊËÀÄÊÅ (ÏÎ ÒÅÏËÎÒÅÕÍÈ×ÅÑÊÈÌ ÒÐÅÁÎÂÀÍÈßÌ) ÎÁÚÅÌ ÊËÀÄÊÈ ÎÑÎÁÎ ÍÅ ÂÊËÞ×ÀÞÒÑß.
Ñ ÓØÈÐÅÍÍÛÌ ÂÍÓÒÐÅÍÍÈÌ ÂÅÐÒÈÊÀËÜÍÛÌ ØÂÎÌ ÍÀ ÊÀÆ- 2.5. ÎÁÚÅÌ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÌÀÒÅÐÈÀËÎÂ, ÎÒËÈ-
ÄÛÅ 10 ÌÌ ÓÂÅËÈ×ÅÍÈß ÒÎËÙÈÍÛ ÊËÀÄÊÈ ÍÎÐÌÛ ÐÀÑÕÎ- ×ÀÞÙÈÕÑß ÎÒ ÌÀÒÅÐÈÀËÀ ÊËÀÄÊÈ (ÆÅËÅÇÎÁÅÒÎÍÍÛÅ ÊÎ-
ÄÀ ÊÈÐÏÈ×À ÓÌÅÍÜØÀÒÜ ÍÀ 7 ØÒ., À ÐÀÑÒÂÎÐÀ - ÓÂÅ- ËÎÍÍÛ, ÏÎÄÊËÀÄÍÛÅ ÏËÈÒÛ, ÏÅÐÅÌÛ×ÊÈ, ÔÓÍÄÀÌÅÍÒÍÛÅ
ËÈ×ÈÂÀÒÜ ÍÀ 0,014 Ì3 ÍÀ 1 Ì3 ÊËÀÄÊÈ. ÁÀËÊÈ, ÑÀÍÈÒÀÐÍÎ-ÒÅÕÍÈ×ÅÑÊÈÅ È ÒÅÏËÎÂÛÅ ÏÀÍÅËÈ È
1.17. ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÒÀÁËÈÖ 28-34 ÐÀÑÏÐÎÑ- Ò.Ï.), ÑËÅÄÓÅÒ ÈÑÊËÞ×ÀÒÜ ÈÇ ÎÁÚÅÌÀ ÊËÀÄÊÈ.
ÒÐÀÍßÞÒÑß ÍÀ ÐÀÁÎÒÛ ÏÎ ÓÑÒÐÎÉÑÒÂÓ ÌÓÑÎÐÎÏÐÎÂÎÄÎÂ ÃÍÅÇÄÀ ÈËÈ ÁÎÐÎÇÄÛ ÄËß ÇÀÄÅËÊÈ ÊÎÍÖÎÂ ÁÀËÎÊ,
 ÑÒÅÍÀÕ, ÑÏÅÖÈÀËÜÍÛÕ ØÀÕÒÀÕ È ËÅÑÒÍÈ×ÍÛÕ ÊËÅÒ- ÏÀÍÅËÅÉ ÏÅÐÅÊÐÛÒÈÉ, ÏËÈÒ, À ÒÀÊÆÅ ÎÁÚÅÌÛ ÍÈØ ÄËß
ÊÀÕ ÆÈËÛÕ È ÎÁÙÅÑÒÂÅÍÍÛÕ ÇÄÀÍÈÉ ÑÎ ÑÒÂÎËÎÌ ÈÇ ÎÒÎÏËÅÍÈß, ÂÅÍÒÈËßÖÈÎÍÍÛÕ È ÄÛÌÎÂÛÕ ÊÀÍÀËÎÂ,
ÀÑÁÅÑÒÎÖÅÌÅÍÒÍÛÕ ÁÅÇÍÀÏÎÐÍÛÕ ÒÐÓÁ ÄÈÀÌÅÒÐΠ400 ÑÒÓÏÅÍÅÉ È Ò.Ï. ÈÇ ÎÁÚÅÌÀ ÊËÀÄÊÈ ÍÅ ÈÑÊËÞ×ÀÞÒÑß,
ÌÌ È Ó×ÈÒÛÂÀÞÒ ÂÅÑÜ ÊÎÌÏËÅÊÑ ÐÀÁÎÒ, ÂÊËÞ×Àß ÓÑ- ÎÁÚÅÌ ÍÈØ ÄËß ÂÑÒÐÎÅÍÍÎÃÎ ÎÁÎÐÓÄÎÂÀÍÈß Â ÎÁÚÅÌ
ÒÀÍÎÂÊÓ ÎÁÎÐÓÄÎÂÀÍÈß È ÀÍÒÈÊÎÐÐÎÇÈÉÍÓÞ ÎÊÐÀÑÊÓ ÊËÀÄÊÈ ÍÅ ÂÊËÞ×ÀÅÒÑß.
ÌÅÒÀËËÈ×ÅÑÊÈÕ ÄÅÒÀËÅÉ. 2.6. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÊËÀÄÊÅ ÑÒÅÍ Ñ ÎÁËÈÖÎÂÊÎÉ
ÏÐÈ ÍÅÎÁÕÎÄÈÌÎÑÒÈ ÂÛÄÅËÅÍÈß ÄËß ÂÇÀÈÌÎÐÀÑ×Å-  ÏÐÎÖÅÑÑÅ ÊËÀÄÊÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ÏËÈÒÀÌÈ ÈÑ×ÈÑËß-
ÒΠÍÎÐÌ È ÑÒÎÈÌÎÑÒÈ ÍÀ ÎÊÐÀÑÊÓ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÅÒÑß ÏÎ ÏÐÎÅÊÒÍÎÉ ÏËÎÙÀÄÈ ÑÒÅÍ ÇÀ ÂÛ×ÅÒÎÌ ÏÐÎÅ-
ÄÅÒÀËÅÉ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÑËÅÄÓÅÒ ÏÎËÜÇÎÂÀÒÜÑß ÒÀÁË. ÌÎÂ ÏÎ ÍÀÐÓÆÍÎÌÓ ÎÁÂÎÄÓ ÊÎÐÎÁÎÊ.
32-34. 2.7. ÏÐÈ ÊËÀÄÊÅ ÑÒÅÍ ÊÈÐÏÈ×À Ñ ÂÎÇÄÓØÍÎÉ
ÎÁÙÅÑÒÐÎÈÒÅËÜÍÛÅ È ÑÀÍÈÒÀÐÍÎ-ÒÅÕÍÈ×ÅÑÊÈÅ ÐÀ- ÏÐÎÑËÎÉÊÎÉ ÎÁÚÅÌ ÂÎÇÄÓØÍÎÉ ÏÐÎÑËÎÉÊÈ ÍÅ ÈÑÊËÞ×À-
ÁÎÒÛ ÏÎ ÓÑÒÐÎÉÑÒÂÓ ÌÓÑÎÐÎÑÁÎÐÍÛÕ ÊÀÌÅÐ ÍÀÄËÅÆÈÒ ÅÒÑß.
ÍÎÐÌÈÐÎÂÀÒÜ È ÐÀÑÖÅÍÈÂÀÒÜ ÄÎÏÎËÍÈÒÅËÜÍÎ. 2.8. ÊËÀÄÊÀ ÑÒÅÍ ÈÇ ÊÈÐÏÈ×À Ñ ÓÒÅÏËÅÍÈÅÌ Ñ
1.18. ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÒÀÁË. 35,36 Ó×ÈÒÛÂÀÞÒ ÂÍÓÒÐÅÍÍÅÉ ÑÒÎÐÎÍÛ ÒÅÐÌÎÈÇÎËßÖÈÎÍÍÛÌÈ ÏËÈÒÀÌÈ
ÎÏÐÅÄÅËßÅÒÑß ÁÅÇ Ó×ÅÒÀ ÒÎËÙÈÍÛ ÏËÈÒ ÓÒÅÏËÈÒÅËß. ÐÈÇÎÍÒÀËÜÍÎÉ ÏÐÎÅÊÖÈÈ ÍÀ ÎÑÍÎÂÀÍÈÅ.
2.9. ÍÎÐÌÛ È ÐÀÑÖÅÍÊÈ ÒÀÁË.16,17 ÄÀÍÛ ÍÀ 1 ÅÑËÈ ÂÍÓÒÐÅÍÍÈÅ ËÅÑÀ ÓÑÒÀÍÀÂËÈÂÀÞÒÑß ÒÎËÜÊÎ
Ì3 ÊËÀÄÊÈ ÏÎ ÎÁÌÅÐÓ Ó×ÀÑÒÊΠÑÒÅÍÛ ÂÌÅÑÒÅ Ñ ÂÛÑ- ÄËß ÎÒÄÅËÊÈ ÑÒÅÍ (ÂÄÎËÜ ÑÒÅÍ) È ÍÅ ÈÌÅÞÒ ÑÏËÎØ-
ÒÓÏÀÞÙÈÌÈ ÍÀ ÍÅÉ ÊÀÐÍÈÇÀÌÈ, ÏÎßÑÊÀÌÈ È ÄÐÓÃÈÌÈ ÍÎÃÎ ÍÀÑÒÈËÀ ÏÎ ÂÑÅÌÓ ÏÎÌÅÙÅÍÈÞ ÄËß ÎÒÄÅËÊÈ ÏÎ-
ÝËÅÌÅÍÒÀÌÈ ÔÀÑÀÄÀ,  ÏÐÅÄÅËÀÕ Ó×ÀÑÒÊΠÑÒÅÍ, ÎÁ- ÒÎËÊÀ, ÒÎ ÏËÎÙÀÄÜ ÈÕ ÈÑ×ÈÑËßÅÒÑß ÏÎ ÂÅÐÒÈÊÀËÜÍÎÉ
ËÈÖÎÂÀÍÍÛÕ ËÈÖÅÂÛÌ ÏÐÎÔÈËÜÍÛÌ ÊÈÐÏÈ×ÎÌ ÈËÈ ËÈÖÅ- ÏÐÎÅÊÖÈÈ ËÅÑΠÍÀ ÑÒÅÍÛ, À ÍÎÐÌÈÐÎÂÀÍÈÅ ÏÐÎÈÇÂÎ-
ÂÛÌÈ ÏÐÎÔÈËÜÍÛÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ÊÀÌÍßÌÈ. ÄÈÒÑß ÏÎ ÃÐÀÔÅ 2, ÒÀÁË. 35, ÊÀÊ ÍÀÐÓÆÍÛÕ ËÅÑÎÂ
2.10. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÓÑÒÐÎÉÑÒÂÓ ÏÅÐÅÃÎÐÎÄÎÊ ÄËß ÎÒÄÅËÎ×ÍÛÕ ÐÀÁÎÒ.
ÑËÅÄÓÅÒ ÈÑ×ÈÑËßÒÜ ÏÎ ÏÐÎÅÊÒÍÎÉ ÏËÎÙÀÄÈ ÇÀ ÂÛ×Å- 2.16. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÊËÀÄÊÅ ÏÅ×ÅÉ, ÎÒÎÏÈ-
ÒÎÌ ÏÎ ÍÀÐÓÆÍÎÌÓ ÎÁÂÎÄÓ ÊÎÐÎÁÎÊ. ÒÅËÜÍÛÕ Î×ÀÃÎÂ È ÄÛÌÎÂÛÕ ÒÐÓÁ ÍÀÄËÅÆÈÒ ÈÑ×ÈÑËßÒÜ
2.11. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÐÀÑØÈÂÊÅ ØÂΠÑËÅÄÓÅÒ ÁÅÇ ÂÛ×ÅÒÀ ÏÓÑÒÎÒ, ÏÐÈ ÝÒÎÌ ÎÁÚÅÌ ÂÅÐÒÈÊÀËÜÍÛÕ È
ÎÏÐÅÄÅËßÒÜ ÏÎ ÏËÎÙÀÄÈ ÐÀÑØÈÂÀÅÌÛÕ ÑÒÅÍ ÁÅÇ ÂÛ×Å- ÃÎÐÈÇÎÍÒÀËÜÍÛÕ ÐÀÇÄÅËÎÊ È ÕÎËÎÄÍÛÕ ×ÅÒÂÅÐÒÅÉ
ÒÀ ÏËÎÙÀÄÈ ÏÐÎÅÌÎÂ. Ó×ÈÒÛÂÀÒÜ ÍÅ ÑËÅÄÓÅÒ.
2.12. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÊËÀÄÊÅ ÖÈËÈÍÄÐÈ×ÅÑÊÈÕ ÎÁÚÅÌ ÊËÀÄÊÈ ÏÅ×ÅÉ, ÎÁËÈÖÎÂÛÂÀÅÌÛÕ ÈÇÐÀÇÖÀ-
ÑÂÎÄΠÈÑ×ÈÑËßÅÒÑß ÏÎ ÏËÎÙÀÄÈ ÃÎÐÈÇÎÍÒÀËÜÍÎÉ ÌÈ, ÎÏÐÅÄÅËßÅÒÑß ÏÎ ÐÀÇÌÅÐÀÌ ÊËÀÄÊÈ ÁÅÇ Ó×ÅÒÀ
ÏÐÎÅÊÖÈÈ ÏÅÐÅÊÐÛÒÈß ÈËÈ ÏÎÊÐÛÒÈß Â ÑÂÅÒÓ ÌÅÆÄÓ ÎÁËÈÖÎÂÊÈ.
ÊÀÏÈÒÀËÜÍÛÌÈ ÑÒÅÍÀÌÈ, ÍÀ ÊÎÒÎÐÛÅ ÎÍÈ ÎÏÈÐÀÞÒÑß. ÏËÎÙÀÄÜ ÏÅ×ÅÉ ÏÐÈ ÈÑ×ÈÑËÅÍÈÈ ÈÕ ÎÁÚÅÌÀ ÏÐÈ-
2.13. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÓÑÒÐÎÉÑÒÂÓ ÊÐÛËÅÖ ÑËÅ- ÍÈÌÀÅÒÑß ÏÎ ÑÅ×ÅÍÈÞ ÍÀ ÓÐÎÂÍÅ ÒÎÏÊÈ, À ÂÛÑÎÒÀ -
ÄÓÅÒ ÈÑ×ÈÑËßÒÜ ÏÎ ÏÎËÍÎÉ ÏËÎÙÀÄÈ ÃÎÐÈÇÎÍÒÀËÜÍÎÉ ÎÒ ÎÑÍÎÂÀÍÈß ÄÎ ÂÅÐÕÀ ÏÅ×È.
ÏÐÎÅÊÖÈÈ ÊÐÛËÜÖÀ, ÂÊËÞ×Àß ÑÒÓÏÅÍÈ. ÏËÎÙÀÄÜ ÎÁËÈÖÎÂÊÈ ÏÅ×ÅÉ ÈÇÐÀÇÖÀÌÈ ÏÐÈÍÈÌÀÅÒ-
2.14. ÎÁÚÅÌ ÐÀÁÎÒ ÏÎ ÓÊËÀÄÊÅ ÏÎÄÎÊÎÍÍÛÕ ÏËÈÒ Ñß ÏÎ ÍÀÐÓÆÍÛÌ ÐÀÇÌÅÐÀÌ ÎÁËÈÖÎÂÀÍÍÛÕ ÃÐÀÍÅÉ.
ÑËÅÄÓÅÒ ÈÑ×ÈÑËßÒÜ Ñ Ó×ÅÒÎÌ ÇÀÄÅËÊÈ ÈÕ Â ÑÒÅÍÛ. 2.17. ÊËÀÄÊÀ ÒÐÓÁ, ÏÐÈÌÛÊÀÞÙÈÕ Ê ÑÒÅÍÀÌ ÇÄÀ-
2.15. ÓÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÍÀÐÓÆÍÛÕ ÈÍÂÅÍÒÀ- ÍÈß, ÂÊËÞ×ÀÅÒÑß Â ÎÁÚÅÌ ÎÑÍÎÂÍÎÉ ÊËÀÄÊÈ ÑÒÅÍ.
ÐÍÛÕ ËÅÑΠÈÑ×ÈÑËßÅÒÑß ÏÎ ÏËÎÙÀÄÈ ÂÅÐÒÈÊÀËÜÍÎÉ ÊËÀÄÊÀ ÒÐÓÁ È ÊÀÍÀËÎÂ, ÂÛÕÎÄßÙÈÕ ÇÀ ÏÐÅÄÅËÛ
ÏÐÎÅÊÖÈÈ ÈÕ ÍÀ ÔÀÑÀÄ ÇÄÀÍÈß, ÂÍÓÒÐÅÍÍÈÕ - ÏÎ ÃÎ- ÑÒÅÍ, ÍÎÐÌÈÐÓÅÒÑß È ÐÀÑÖÅÍÈÂÀÅÒÑß ÏÎ ÒÀÁË. 41.
3. ÊÎÝÔÔÈÖÈÅÍÒÛ Ê ÑÌÅÒÍÛÌ ÍÎÐÌÀÌ È ÐÀÑÖÅÍÊÀÌ
ÒÀÁËÈÖÀ 1
------------------------------------------------------------------------------------------------------
ÓÑËÎÂÈß ÏÐÈÌÅÍÅÍÈß ¦ NN ÒÀÁËÈÖ È ÃÐÀÔ ¦ ÊÎÝÔÔÈÖÈÅÍÒÛ Ê
¦ ¦-------------------------------
¦ ¦ÍÎÐÌÀÌ ¦ÇÀÐÀ- ¦ÍÎÐÌÀÌ ¦ÍÎÐÌÀÌ
¦ ¦ÇÀÒÐÀÒ ¦ÁÎÒÍÎÉ ¦ÇÀÒÐÀÒ ¦ÐÀÑÕÎ-
¦ ¦ÒÐÓÄÀ ¦ÏËÀÒÅ ¦È ÑÒÎÈ-¦ÄÀ ÌÀ-
¦ ¦ ¦ ¦ÌÎÑÒÈ ¦ÒÅÐÈÀ-
¦ ¦ ¦ ¦ÝÊÑÏËÓ-¦ ËÎÂ
¦ ¦ ¦ ¦ÀÒÀÖÈÈ ¦
¦ ¦ ¦ ¦ÌÀØÈÍ ¦
------------------------------------------------------------------------------------------------------
1 ¦ 2 ¦ 3 ¦ 4 ¦ 5 ¦ 6
------------------------------------------------------------------------------------------------------
3.1. ÏÐÈ ÊËÀÄÊÅ ÈÇ ÊÈÐÏÈ×À ÐÀÇÌÅÐÎÌ ¦ ¦ ¦ ¦ ¦
250Õ120Õ88 ÌÌ Ê ÐÀÑÕÎÄÓ: ¦ ¦ ¦ ¦ ¦
ÊÈÐÏÈ×À ¦ 6ÃÐ.1-11;7ÃÐ.3-6; ¦ ¦ ¦ ¦ 0,77
¦ 8ÃÐ.1-8;10;15-20 ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
ÐÀÑÒÂÎÐÀ ¦ 6ÃÐ.1-11;7ÃÐ.3-6; ¦ ¦ ¦ ¦ 0,9
¦ 8ÃÐ.1-8;10;15-20 ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
3.2. ÐÀÑØÈÂÊÀ ØÂΠÏÐÈ ÊËÀÄÊÅ ÈÇ ÊÈÐÏÈ×À ¦ 11ÃÐ.1 ¦ 0,75 ¦ 0,75 ¦ ¦
ÐÀÇÌÅÐÎÌ 250Õ120Õ88 ÌÌ ¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
3.3. ÇÀÏÎËÍÅÍÈÅ ÊÀÐÊÀÑÍÛÕ ÑÒÅÍ Ñ ÏÎÄÊÎÑÀÌÈ ¦ 6ÃÐ.10,11 ¦ 1,15 ¦ 1,15 ¦ ¦
¦ ¦ ¦ ¦ ¦
3.4. ÎÁËÈÖÎÂÊÀ ÑÒÅÍ ÊÈÐÏÈ×ÎÌ ÑÈËÈÊÀÒÍÛÌ ¦ 15ÃÐ.1-12 ¦ 0,9 ¦ 0,9 ¦ ¦
¦ ¦ ¦ ¦ ¦
3.5. ÒÎ ÆÅ, ÊÅÐÀÌÈ×ÅÑÊÈÌ ¦ 15ÃÐ.7-12 ¦ 0,9 ¦ 0,9 ¦ ¦
¦ ¦ ¦ ¦ ¦
3.6. ÏÐÈ ÎÁËÈÖÎÂÊÅ ÑÒÅÍ Ñ ÄÂÓÕ ÑÒÎÐÎÍ Ê ¦ ¦ ¦ ¦ ¦
ÐÀÑÕÎÄÓ: ¦ 15ÃÐ.3,4,9,10,15, ¦ ¦ ¦ ¦ 0,5
ÊÈÐÏÈ×À ÊÅÐÀÌÈ×ÅÑÊÎÃÎ, ÑÈËÈÊÀÒÍÎÃÎ ÈËÈ ¦ 16 ¦ ¦ ¦ ¦
ÏÓÑÒÎÒÅËÎÃÎ È ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ¦ 15ÃÐ.5,6,11,12,17,¦ ¦ ¦ ¦ 0,6
ÊËÀÄÎ×ÍÛÕ, ¦ 18 ¦ ¦ ¦ ¦
ÊÈÐÏÈ×À ÊÅÐÀÌÈ×ÅÑÊÎÃÎ ËÈÖÅÂÎÃÎ, ÊÀÌÍÅÉ ¦ 15ÃÐ.3-6,9-12, ¦ ¦ ¦ ¦ 2
ÊÅÐÀÌÈ×ÅÑÊÈÕ ËÈÖÅÂÛÕ ÐßÄÎÂÛÕ ¦ 15-18 ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁËÈÖÛ
------------------------------------------------------------------------------------------------------
1 ¦ 2 ¦ 3 ¦ 4 ¦ 5 ¦ 6
------------------------------------------------------------------------------------------------------
3.7. ÊËÀÄÊÀ ÑÒÅÍ Ñ ÎÁËÈÖÎÂÊÎÉ ËÈÖÅÂÛÌ ¦ ¦ ¦ ¦ ¦
ÊÈÐÏÈ×ÎÌ Ñ ÑÎÂÌÅÙÅÍÍÛÌ ÂÅÐÒÈÊÀËÜÍÛÌ ØÂÎÌ, ¦ ¦ ¦ ¦ ¦
Ñ ÎÁËÈÖÎÂÊÎÉ ÈÇ ÊÈÐÏÈ×À 2-Õ ÖÂÅÒΠÏÎ ÐÈ- ¦ ¦ ¦ ¦ ¦
ÑÓÍÊÓ ÀÂÒÎÐÀ, ÑÎ ÑÏËÎØÍÛÌ ÀÐÕÈÒÅÊÒÓÐÍÛÌ ¦ ¦ ¦ ¦ ¦
ÐÈÑÓÍÊÎÌ ÏÐÈ ÒÎËÙÈÍÅ ÑÒÅÍ 380 ÌÌ ¦ 15ÃÐ.1,2 ¦ 1,2 ¦ 1,7 ¦ ¦
ÒÎ ÆÅ 510,640 ÌÌ ¦ 15ÃÐ.3-6 ¦ 1,15 ¦ 1,15 ¦ ¦
¦ ¦ ¦ ¦ ¦
3.8. ÊËÀÄÊÀ ÑÒÅÍ ÊÐÈÂÎËÈÍÅÉÍÎÃÎ Î×ÅÐÒÀÍÈß ¦ 6;10;13-24; ¦ 1,1 ¦ 1,1 ¦ ¦
¦ 25ÃÐ.1,2 ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
3.9. ÓÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÈÍÂÅÍÒÀÐÍÛÕ ËÅÑÎÂ ¦ ¦ ¦ ¦ ¦
ÄËß ÏÐÎÈÇÂÎÄÑÒÂÀ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÕ È ¦ 35ÃÐ.2,4 ¦ 1,2 ¦ 1,2 ¦ ¦ 1,2
ÎÁÌÓÐÎÂÎ×ÍÛÕ ÐÀÁÎÒ ÍÀ ÎÁÚÅÊÒÀÕ ÝÍÅÐÃÅÒÈ- ¦ 35ÃÐ.3,5 ¦ 1,3 ¦ 1,3 ¦ ¦ 1,5
×ÅÑÊÎÃÎ ÑÒÐÎÈÒÅËÜÑÒÂÀ ¦ ¦ ¦ ¦ ¦
¦ ¦ ¦ ¦ ¦
3.10.ÒÅÐÐÈÒÎÐÈÀËÜÍÛÅ ÊÎÝÔÔÈÖÈÅÍÒÛ Ê ÁÀÇÈÑÍÛÌ ¦ ÂÑÅ ÒÀÁËÈÖÛ ¦ ¦ ¦ ¦
(1-ÃÎ ÒÅÐÐÈÒÎÐÈÀËÜÍÎÃÎ ÐÀÉÎÍÀ) ÇÀÒÐÀÒÀÌ ÍÀ ¦ ¦ ¦ ¦ ¦
ÝÊÑÏËÓÀÒÀÖÈÞ ÑÒÐÎÈÒÅËÜÍÛÕ ÌÀØÈÍ ÏÎ ÒÅÐÐÈ- ¦ ¦ ¦ ¦ ¦
ÒÎÐÈÀËÜÍÛÌ ÐÀÉÎÍÀÌ: ¦ ¦ ¦ ¦ ¦
1,2,4,7,8,34 ¦ ¦ ¦ ¦ 1,0 ¦
3,5,6,11,12-14,40, 22Ñ ¦ ¦ ¦ ¦ 1,02 ¦
9,31,32,33,35 ÀÁ ¦ ¦ ¦ ¦ 0,99 ¦
10,35 ÂÃ,36,37,38,39,41-44 ¦ ¦ ¦ ¦ 0,98 ¦
15,16 ¦ ¦ ¦ ¦ 1,05 ¦
24Ñ ¦ ¦ ¦ ¦ 1,28 ¦
17,19,20 ¦ ¦ ¦ ¦ 1,07 ¦
21Ñ, 25Ñ2, 27Ñ ¦ ¦ ¦ ¦ 1,31 ¦
18 ¦ ¦ ¦ ¦ 1,05 ¦
29Ñ ¦ ¦ ¦ ¦ 1,46 ¦
30Ñ1 ¦ ¦ ¦ ¦ 1,46 ¦
23Ñ1-Ñ8, 25Ñ1 ¦ ¦ ¦ ¦ 1,31 ¦
26Ñ1 ¦ ¦ ¦ ¦ 1,5 ¦
26Ñ2 ¦ ¦ ¦ ¦ 1,5 ¦
28Ñ1 ¦ ¦ ¦ ¦ 1,48 ¦
28Ñ2 ¦ ¦ ¦ ¦ 1,48 ¦
30Ñ2 ¦ ¦ ¦ ¦ 1,41 ¦
45 ¦ ¦ ¦ ¦ 0,98 ¦
ÑÎÄÅÐÆÀÍÈÅ
ÑÒÐ. ÑÒÐ.
ÒÅÕÍÈ×ÅÑÊÀß ×ÀÑÒÜ ......................... ËÈÖÅÂÛÌÈ ÏÐÎÔÈËÜÍÛÌÈ .......
01 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÁÓÒÎÂÎÃÎ ÊÀÌÍß ... 06 ÑÒÅÍÛ ÍÀÐÓÆÍÛÅ ÈÇ ÊÈÐÏÈ×À Ñ
ÎÁËÈÖÎÂÊÎÉ Â ÏÐÎÖÅÑÑÅ ÊËÀÄÊÈ ÊÅ-
ÒÀÁËÈÖÀ 8-2 ÓÑÒÐÎÉÑÒÂÎ ÔÓÍÄÀÌÅÍÒÎÂ, ÐÀÌÈ×ÅÑÊÈÌÈ ÏËÈÒÀÌÈ .............
ÊËÀÄÊÀ ÑÒÅÍ ................
ÒÀÁËÈÖÀ 8-18 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ ÑÒÅÍ ÒÎËÙÈ-
ÒÀÁËÈÖÀ 8-3 ÓÑÒÐÎÉÑÒÂÎ ÎÑÍÎÂÀÍÈß ÏÎÄ ÍÎÉ Â 2 ÊÈÐÏÈ×À Ñ ÎÁËÈÖÎÂÊÎÉ
ÔÓÍÄÀÌÅÍÒÛ ................. ÊÅÐÀÌÈ×ÅÑÊÎÉ ÏËÈÒÊÎÉ .......
ÒÀÁËÈÖÀ 8-4 ÃÈÄÐÎÈÇÎËßÖÈß ÑÒÅÍ, 07 ÑÒÅÍÛ ÍÀÐÓÆÍÛÅ È ÂÍÓÒÐÅÍÍÈÅ
ÔÓÍÄÀÌÅÍÒΠ................ ÊÈÐÏÈ×ÍÛÅ ÎÁËÅÃ×ÅÍÍÛÕ
ÊÎÍÑÒÐÓÊÖÈÉ .....................
ÒÀÁËÈÖÀ 8-5 ÁÎÊÎÂÀß ÈÇÎËßÖÈß ÑÒÅÍ,
ÔÓÍÄÀÌÅÍÒÎÂ ÃËÈÍÎÉ ......... ÒÀÁËÈÖÀ 8-19 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ È ÂÍÓÒÐÅÍÍÈÕ
ÑÒÅÍ .......................
02 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÈÐÏÈ×À ..........
ÒÀÁËÈÖÀ 8-20 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ È ÂÍÓÒÐÅÍÍÈÕ
ÒÀÁËÈÖÀ 8-6 ÊËÀÄÊÀ ÑÒÅÍ ................ ÊÈÐÏÈ×ÍÛÕ ÑÒÅÍ .............
ÒÀÁËÈÖÀ 8-7 ÊËÀÄÊÀ ÏÅÐÅÃÎÐÎÄÎÊ ......... 08 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÐÓÏÍÛÕ ÈÇÂÅÑÒÍß-
ÊÎÂÛÕ ÁËÎÊÎÂ ....................
ÒÀÁËÈÖÀ 8-8 ÊËÀÄÊÀ ÈÇ ÊÈÐÏÈ×À
ÊÎÍÑÒÐÓÊÖÈÉ ................ ÒÀÁËÈÖÀ 8-21 ÊËÀÄÊÀ ÈÇ ÊÐÓÏÍÛÕ ÈÇÂÅÑÒÍß-
ÊÎÂÛÕ ÁËÎÊÎÂ ...............
ÒÀÁËÈÖÀ 8-9 ÑÂÎÄÛ ÖÈËÈÍÄÐÈ×ÅÑÊÈÅ
ÒÎËÙÈÍÎÉ Â 1:2 ÊÈÐÏÈ×À ..... 09 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÀÌÍÅÉ ËÅÃÊÎ-
ÁÅÒÎÍÍÛÕ ........................
ÒÀÁËÈÖÀ 8-10 ÊËÀÄÊÀ ÀÐÌÈÐÎÂÀÍÍÛÕ ÑÒÅÍ ÈÇ
ÊÈÐÏÈ×À  ÐÀÉÎÍÀÕ Ñ ÒÀÁËÈÖÀ 8-22 ÊËÀÄÊÀ ÑÒÅÍ, ÇÀÏÎËÍÅÍÈÅ
ÑÅÉÑÌÈ×ÍÎÑÒÜÞ 7-8 ÁÀËËΠ... ÏÐÎÅÌÎÂ È ÔÀÕÂÅÐÊΠ........
ÒÀÁËÈÖÀ 8-11 ÐÀÑØÈÂÊÀ ØÂÎÂ ÊËÀÄÊÈ ....... 10 ÑÒÅÍÛ È ÏÅÐÅÃÎÐÎÄÊÈ ÈÇ ÊÀÌÍÅÉ
ÈÇÂÅÑÒÊÎÂÛÕ È ÒÓÔÎÂÛÕ ...........
ÒÀÁËÈÖÀ 8-12 ÀÐÌÈÐÎÂÀÍÈÅ ÊËÀÄÊÈ ÑÒÅÍ,
ÊÐÅÏËÅÍÈÅ ÑÂÎÄÎÂ, ÓÑÒÀÍÎÂÊÀ ÒÀÁËÈÖÀ 8-23 ÊËÀÄÊÀ ÑÒÅÍ È ÏÅÐÅÃÎÐÎÄÎÊ
ÌÅÒÀËËÈ×ÅÑÊÈÕ ÐÅØÅÒÎÊ ...... ÍÅÀÐÌÈÐÎÂÀÍÍÛÕ .............
03 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÀÌÍÅÉ ÊÅÐÀÌÈ- 11 ÏÅÐÅÃÎÐÎÄÊÈ .....................
×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ ÊËÀÄÎ×ÍÛÕ..
ÒÀÁËÈÖÀ 8-24 ÓÑÒÀÍÎÂÊÀ ÏÅÐÅÃÎÐÎÄÎÊ ......
ÒÀÁËÈÖÀ 8-13 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ ÑÒÅÍ .......
ÒÀÁËÈÖÀ 8-25 ÓÑÒÀÍÎÂÊÀ ÏÅÐÅÃÎÐÎÄÎÊ ÈÇ
ÒÀÁËÈÖÀ 8-14 ÊËÀÄÊÀ ÏÅÐÅÃÎÐÎÄÎÊ ÒÎËÙÈÍÎÉ ÑÒÅÊËßÍÍÛÕ ÁËÎÊÎÂ È ÇÀÏÎË-
120 ÌÌ ..................... ÍÅÍÈÅ ÏÐÎÅÌΠÑÒÅÊËßÍÍÛÌÈ
ÁËÎÊÀÌÈ ....................
04 ÑÒÅÍÛ ÍÀÐÓÆÍÛÅ ÈÇ ÊÈÐÏÈ×À È
ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒ- 13 ÏËÈÒÛ ÆÅËÅÇÎÁÅÒÎÍÍÛÅ ÏÎÄÎÊÎÍÍÛÅ..
ÍÛÕ Ñ ÎÁËÈÖÎÂÊÎÉ ËÈÖÅÂÛÌ
ÊÈÐÏÈ×ÎÌ, ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ÒÀÁËÈÖÀ 8-26 ÓÊËÀÄÊÀ ÏÎÄÎÊÎÍÍÛÕ ÆÅËÅÇÎ-
ÈËÈ ÑÈËÈÊÀÒÍÛÌÈ ................. ÁÅÒÎÍÍÛÕ ÏËÈÒ ..............
ÒÀÁËÈÖÀ 8-15 ÊËÀÄÊÀ ÑÒÅÍ ................ 14 ÊÐÛËÜÖÀ .........................
05 Ó×ÀÑÒÊÈ ÑÒÅÍ (ÊÀÐÍÈÇÛ,ÏÎßÑÊÈ È ÒÀÁËÈÖÀ 8-27 ÓÑÒÐÎÉÑÒÂÎ ÊÐÛËÅÖ ..........
Ò.Ï) ÈÇ ÊÈÐÏÈ×À È ÊÀÌÍÅÉ ÊÅÐÀÌÈ-
×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ Ñ ÎÁËÈÖÎÂ- 15 ÌÓÑÎÐÎÏÐÎÂÎÄ ÑÎ ÑÒÂÎËÎÌ ÈÇ ÀÑÁÅÑ-
ÊÎÉ ÊÈÐÏÈ×ÎÌ ËÈÖÅÂÛÌ ÏÐÎÔÈËÜÍÛÌ ÒÎÖÅÌÅÍÒÍÛÕ ÒÐÓÁ ................
ÈËÈ ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ
ËÈÖÅÂÛÌÈ ÏÐÎÔÈËÜÍÛÌÈ ............ ÒÀÁËÈÖÀ 8-28 ÌÎÍÒÀÆ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÑÎ
ÑÒÂÎËÎÌ ÈÇ ÀÑÁÎÖÅÌÅÍÒÍÛÕ
ÒÀÁËÈÖÀ 8-16 ÊËÀÄÊÀ Ó×ÀÑÒÊΠÑÒÅÍ ....... ÒÐÓÁ .......................
ÒÀÁËÈÖÀ 8-17 ÊËÀÄÊÀ ÈÇ ÊÀÌÍÅÉ Ñ ÎÁËÈÖÎÂ- ÒÀÁËÈÖÀ 8-29 ÍÀ ÊÀÆÄÛÉ ÝÒÀÆ ÑÂÅÐÕ ÈËÈ
ÊÎÉ ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ÌÅÍÅÅ ÄÅÂßÒÈ ÄÎÁÀÂËßÒÜ ÈËÈ
ÑÒÐ. ÑÒÐ.
ÈÑÊËÞ×ÀÒÜ ..................
ÒÀÁËÈÖÀ 8-30 ÍÀ 1 Ì ÓÄËÈÍÅÍÈß ÑÒÂÎËÀ
ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÏÐÈ ÂÛÑÎÒÅ
ÝÒÀÆÀ ÁÎËÅÅ 2,8 Ì ÄÎÁÀÂËßÒÜ
ÈËÈ ÈÑÊËÞ×ÀÒÜ ..............
ÒÀÁËÈÖÀ 8-31 ÄÎÁÀÂËßÒÜ ÍÀ ÎÄÈÍ ÄÎÏÎËÍÈ-
ÒÅËÜÍÛÉ ÏÐÈÅÌÍÛÉ ÊËÀÏÀÍ ....
ÒÀÁËÈÖÀ 8-32 ÎÊÐÀÑÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ
ÄÅÒÀËÅÉ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ......
ÒÀÁËÈÖÀ 8-33 ÏÐÈ ÎÊÐÀÑÊÅ ÍÀ ÊÀÆÄÛÉ ÝÒÀÆ
ÑÂÅÐÕ ÈËÈ ÌÅÍÅÅ ÄÅÂßÒÈ
ÄÎÁÀÂËßÒÜ ÈËÈ ÈÑÊËÞ×ÀÒÜ ....
ÒÀÁËÈÖÀ 8-34 ÏÐÈ ÎÊÐÀÑÊÅ ÍÀ ÎÄÈÍ ÄÎÏÎËÍÈ-
ÒÅËÜÍÛÉ ÊËÀÏÀÍ ÄÎÁÀÂËßÒÜ ...
16 ÍÀÐÓÆÍÛÅ È ÂÍÓÒÐÅÍÍÈÅ ËÅÑÀ ......
ÒÀÁËÈÖÀ 8-35 ÓÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÈÍÂÅÍ-
ÒÀÐÍÛÕ ËÅÑÎÂ ...............
ÒÀÁËÈÖÀ 8-36 ÓÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÈÍÂÅÍ-
ÒÀÐÍÛÕ ËÅÑÎÂ ...............
17 ÏÅ×È ÎÒÎÏÈÒÅËÜÍÛÅ È Î×ÀÃÈ .......
ÒÀÁËÈÖÀ 8-37 ÎÑÍÎÂÀÍÈß ÏÎÄ ÏÅ×È, Î×ÀÃÈ È
ÒÐÓÁÛ ......................
ÒÀÁËÈÖÀ 8-38 ÎÑÍÎÂÀÍÈß ÏÎÄ ÏÅ×È, Î×ÀÃÈ È
ÒÐÓÁÛ ......................
ÒÀÁËÈÖÀ 8-39 ÊËÀÄÊÀ ÏÅ×ÅÉ, Î×ÀÃΠ.......
ÒÀÁËÈÖÀ 8-40 ÓÑÒÀÍÎÂÊÀ Î×ÀÃΠÌÅÒÀËËÈ-
×ÅÑÊÈÕ .....................
ÒÀÁËÈÖÀ 8-41 ÊËÀÄÊÀ ÄÛÌÎÂÛÕ ÊÈÐÏÈ×ÍÛÕ
ÒÐÓÁ .......................
ÒÀÁËÈÖÀ 8-42 ÎÒÄÅËÊÀ ÏÅ×ÅÉ ..............
01 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÁÓÒÎÂÎÃÎ ÊÀÌÍß
ÒÀÁËÈÖÀ 8-2
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ Ñ ÏÎÄÁÎÐÎÌ È ÃÐÓÁÎÉ ÏÐÈÊÎËÊÎÉ ÊÀÌÍß Ñ ÎÁÄÅËÊÎÉ ÎÒÊÎÑÎÂ. 02.ÓÑÒÐÎÉÑÒÂÎ ÃÎÐÈÇÎÍÒÀËÜÍÎÉ
ÈÇÎËßÖÈÈ Â ÔÓÍÄÀÌÅÍÒÀÕ È ÑÒÅÍÀÕ ÏÎÄÂÀËΠÈÇ ÄÂÓÕ ÑËÎÅ ÐÓËÎÍÍÛÕ ÌÀÒÅÐÈÀËΠÏÎ ÖÅÌÅÍÒÍÎÉ ÑÒ߯ÊÅ (ÃÐÀÔÛ 1,4-9)
ÈËÈ ÖÅÌÅÍÒÍÛÌ ÐÀÑÒÂÎÐÎÌ Ñ ÆÈÄÊÈÌ ÑÒÅÊËÎÌ (ÃÐÀÔÀ 2). 03.ÎÁËÈÖÎÂÊÀ ÊÈÐÏÈ×ÎÌ ÑÒÅÍ È ÏÐÎÅÌΠ(ÃÐÀÔÛ 6-9).
04.ÐÀÑØÈÂÊÀ ØÂÎÂ (ÃÐÀÔÛ 6-9). 05.ÓÑÒÐÎÉÑÒÂÎ Â ÏÎÄÏÎÐÍÛÕ ÑÒÅÍÀÕ ÑËÈÂÀ ÈÇ ÖÅÌÅÍÒÍÎÃÎ ÐÀÑÒÂÎÐÀ
(ÃÐÀÔÛ 4,5,8,9).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÓÑÒÐÎÉÑÒÂÎ ÔÓÍÄÀÌÅÍÒΠ¦ÊËÀÄÊÀ ÑÒÅÍ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ËÅÍÒÎ×ÍÛÕ ¦ÑÒÎËÁÎÂÛÕ ¦ÌÀÑÑÈÂΠØÈÐȦÁÅÇ ÎÁËÈÖÎÂÊÈ
¦ ¦ ¦ ¦ ¦ÍÎÉ ÁÎËÅÅ 2 ̦----------------------------
¦ ¦ ¦ ¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦ ¦ ¦ ¦----------------------------
¦ ¦ ¦ ¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-2-1 ¦ 8-2-2 ¦ 8-2-3 ¦ 8-2-4 ¦ 8-2-5
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 3.94 5.82 3.72 4.83 4.75
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.15 0.15 0.14 0.23 0.14
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.47 0.45 0.42 0.71 0.43
-------------------------------------------------------------------------------------------------------------------------------
ÃÈÄÐÎÈÇÎËßÖÈÎÍÍÛÅ ÐÓËÎÍÍÛÅ (113-9051 ) Ì2 1.83 0.24 0.24
ÌÀÒÅÐÈÀËÛ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0001 ) Ì3 0.13 0.13 0.12 0.08 0.08
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0002 ) Ì3 0.12 0.12
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 50
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.26 0.27 0.25 0.17 0.17
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÀÌÅÍÜ ÁÓÒÎÂÛÉ (408-9011 ) Ì3 1.03 1.03 1.03 1.03 1.03
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.69 0.05 0.01 0.17 0.17
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.1 0.01 0.03 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.68 4.34 2.52 3.33 3.28
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.47 0.45 0.42 0.71 0.43
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.14 0.14 0.13 0.21 0.13
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.69 0.05 0.01 0.17 0.17
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 3.84 4.84 2.95 4.21 3.88
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-2
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÑÒÅÍ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦Ñ ÎÁËÈÖÎÂÊÎÉ ÊÈÐÏÈ×ÎÌ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÒÎËÜÊÎ ÏÐÎÅÌΠ¦ÑÒÅÍ Ñ ÎÄÍÎÉ ÑÒÎÐÎÍÛ È ÏÐÎÅÌÎÂ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-2-6 ¦ 8-2-7 ¦ 8-2-8 ¦ 8-2-9
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.11 5.09 5.21 5.12
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.24 0.15 0.27 0.18
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.72 0.45 0.81 0.54
-----------------------------------------------------------------------------------------------------------------------------
ÃÈÄÐÎÈÇÎËßÖÈÎÍÍÛÅ ÐÓËÎÍÍÛÅ (113-9051 ) Ì2 0.57 0.57 0.35 0.35
ÌÀÒÅÐÈÀËÛ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0001 ) Ì3 0.13 0.13 0.06 0.06
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0002 ) Ì3 0.17 0.17
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 50
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.25 0.25 0.12 0.12
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.01 0.01 0.08 0.08
ÊÀÌÅÍÜ ÁÓÒÎÂÛÉ (408-9011 ) Ì3 1.01 1.01 0.82 0.82
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.33 0.33 0.17 0.17
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05 0.05 0.03 0.03
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.54 3.48 3.65 3.59
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.72 0.45 0.81 0.54
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.22 0.14 0.24 0.16
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.33 0.33 0.17 0.17
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 4.59 4.26 4.63 4.3
ÒÀÁËÈÖÀ 8-3 ÓÑÒÐÎÉÑÒÂÎ ÎÑÍÎÂÀÍÈß ÏÎÄ ÔÓÍÄÀÌÅÍÒÛ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÐÀÇÐÀÂÍÈÂÀÍÈÅ È ÒÐÀÌÁÎÂÀÍÈÅ ÎÑÍÎÂÀÍÈß.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÎÑÍÎÂÀÍÈß
------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÏÅÑ×ÀÍÎÃÎ ¦ÙÅÁÅÍÎ×ÍÎÃÎ ¦ÃÐÀÂÈÉÍÎÃÎ
¦ ¦ ¦---------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-3-1 ¦ 8-3-2 ¦ 8-3-3
------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 0.78 0.85 0.85
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.18 0.18 0.18
------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.54 0.56 0.56
------------------------------------------------------------------------------------------------------------------------------
ÃÐÀÂÈÉ (406-9001 ) Ì3 1.15
ÏÅÑÎÊ (408-9020 ) Ì3 1.1
ÙÅÁÅÍÜ (408-9080 ) Ì3 1.15
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.04 0.04 0.04
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01 0.01 0.01
------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 0.5 0.55 0.55
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.54 0.56 0.56
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.16 0.17 0.17
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.04 0.04 0.04
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 1.08 1.15 1.15
ÒÀÁËÈÖÀ 8-4 ÃÈÄÐÎÈÇÎËßÖÈß ÑÒÅÍ, ÔÓÍÄÀÌÅÍÒÎÂ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.×ÀÑÒÈ×ÍÀß ÏÐÈÊÎËÊÀ ÈÇÎËÈÐÓÅÌÎÉ ÏÎÂÅÐÕÍÎÑÒÈ (ÃÐÀÔÛ 1,4,8). 02.ÂÛÐÀÂÍÈÂÀÍÈÅ ÈÇÎËÈÐÓÅÌÎÉ
ÏÎÂÅÐÕÍÎÑÒÈ ÐÀÑÒÂÎÐÎÌ (ÃÐÀÔÛ 2,3,8). 03.ÍÀÍÅÑÅÍÈÅ ÈÇÎËßÖÈÎÍÍÎÃÎ ÑËÎß ÈÇ ÐÀÑÒÂÎÐÀ Ñ ÆÈÄÊÈÌ ÑÒÅÊËÎÌ
(ÃÐÀÔÛ 1,4). 04.ÎÃÐÓÍÒÎÂÊÀ ÏÎÂÅÐÕÍÎÑÒÈ (ÃÐÀÔÛ 5,7). 05.ÍÀÊËÅÉÊÀ ÐÓËÎÍÍÛÕ ÌÀÒÅÐÈÀËÎÂ Ñ ÐÀÇÎÃÐÅÂÀÍÈÅÌ
ÌÀÑÒÈÊÈ (ÃÐÀÔÛ 2,3,5,6). 06.ÍÀ ÍÅÑÅÍÈÅ ÑËÎÅÂ ÁÈÒÓÌÍÎÉ ÌÀÑÒÈÊÈ Ñ ÐÀÇÎÃÐÅÂÀÍÈÅÌ ÅÅ (ÃÐÀÔÀ 7).
07.ÓÊËÀÄÊÀ ÄÎÏÎËÍÈÒÅËÜÍÛÕ ÑËÎÅ ÃÈÄÐÎÈÇÎËßÖÈÎÍÍÛÕ ÌÀÒÅÐÈÀËΠ ÌÅÑÒÀÕ ÑÎÏÐ߯ÅÍÈß ÁÎÊÎÂÎÉ ÈÇÎËßÖÈÈ Ñ
ÃÎÐÈÇÎÍÒÀËÜÍÎÉ (ÃÐÀÔÛ 5,6).
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÈÇÎËÈÐÓÅÌÎÉ ÏÎÂÅÐÕÍÎÑÒÈ
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÃÎÐÈÇÎÍÒÀËÜÍÀß ¦ÁÎÊÎÂÀß
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÖÅÌÅÍÒÍÀß Ñ ÆÈÄ-¦ÎÊËÅÅ×ÍÀß ¦ÖÅÌÅÍÒÍÀß Ñ ÆÈÄ-
¦ ¦ ¦ÊÈÌ ÑÒÅÊËÎÌ ¦---------------------------------¦ÊÈÌ ÑÒÅÊËÎÌ
¦ ¦ ¦ ¦Â 1 ÑËÎÉ ¦Â 2 ÑËÎß ¦
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-4-1 ¦ 8-4-2 ¦ 8-4-3 ¦ 8-4-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 38.2 14.3 20.1 88.8
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.76 1.31 2.05 0.69
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.32 3.96 6.22 2.1
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÑÒÈÊÀ ÌÎÐÎÇÎÑÒÎÉÊÀß (101-0612 ) Ò 0.22 0.42
ÁÈÒÓÌÍÎ-ÌÀÑËßÍÀß ÌÁ-50
ÃÈÄÐÎÈÇÎËßÖÈÎÍÍÛÅ ÐÓËÎÍÍÛÅ (113-9051 ) Ì2 110 220
ÌÀÒÅÐÈÀËÛ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0001 ) Ì3 3.1 2.5 2.5
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÎÒÄÅËÎ×ÍÛÅ (402-0036 ) Ì3 2.8
Ò߯ÅËÛÅ ÖÅÌÅÍÒÍÛÅ ÑÎÑÒÀÂÀ 1:3
ÑÒÅÊËÎ ÆÈÄÊÎÅ ÊÀËÈÉÍÎÅ 611-3068 Ò 0.05 0.05
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.62 6.46 12.52 0.42
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.09 0.97 1.88 0.06
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 25.8 9.82 14 66.3
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.32 3.96 6.22 2.1
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.7 1.19 1.87 0.63
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.62 6.46 12.52 0.42
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 28.74 20.24 32.74 68.82
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.45 6.45
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.97 0.97
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-4
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÁÎÊÎÂÀß
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÎÊËÅÅ×ÍÀß ÏÎ ÂÛÐÀÂÍÅÍÍÎÉ ÏÎÂÅÐÕ- ¦ÎÁÌÀÇÎ×ÍÀß ¦Ñ ÂÛÐÀÂÍÈÂÀÍÈÅÌ
¦ ¦ ¦ÍÎÑÒÈ ÁÓÒÎÂÎÉ ÊËÀÄÊÈ, ÊÈÐÏÈ×Ó È ¦ÁÈÒÓÌÍÀß ¦ÏÎÂÅÐÕÍÎÑÒÈ
¦ ¦ ¦ÁÅÒÎÍÓ ¦-----------------¦ÁÓÒÎÂÎÉ ÊËÀÄÊÈ
¦ ¦ ¦---------------------------------¦Â 2 ÑËÎß ÏÎ ÂÛ- ¦
¦ ¦ ¦Â 2 ÑËÎß ¦ÍÀ ÊÀÆÄÛÉ ÑËÎÉ ¦ÐÀÂÍÅÍÍÎÉ ÏÎÂÅÐÕ-¦
¦ ¦ ¦ ¦ÑÂÅÐÕ 2-Õ ¦ÍÎÑÒÈ ÁÓÒÎÂÎÉ ¦
¦ ¦ ¦ ¦ÄÎÁÀÂËßÒÜ ¦ÊËÀÄÊÈ, ÊÈÐÏÈ×Ó, ¦
¦ ¦ ¦ ¦ ¦ÁÅÒÎÍÓ ¦
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-4-5 ¦ 8-4-6 ¦ 8-4-7 ¦ 8-4-8
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 46.8 22.6 21.2 96.7
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 1.51 0.76 0.7 0.73
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 4.57 2.32 2.12 2.2
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÑÒÈÊÀ ÌÎÐÎÇÎÑÒÎÉÊÀß (101-0612) Ò 0.44 0.23 0.24
ÁÈÒÓÌÍÎ-ÌÀÑËßÍÀß ÌÁ-50
ÃÈÄÐÎÈÇÎËßÖÈÎÍÍÛÅ ÐÓËÎÍÍÛÅ ÌÀÒÅÐÈÀËÛ (113-9051) Ì2 230 115
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÎÒÄÅËÎ×ÍÛÅ (402-0036) Ì3 3.05
Ò߯ÅËÛÅ ÖÅÌÅÍÒÍÛÅ ÑÎÑÒÀÂÀ 1:3
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 13.39 6.87 3.96 0.21
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 2.01 1.03 0.59 0.03
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 36.3 17.5 16.6 73.9
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 4.57 2.32 2.12 2.2
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 1.37 0.7 0.64 0.66
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 13.39 6.87 3.96 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 54.26 26.69 22.68 76.31
ÒÀÁËÈÖÀ 8-5 ÁÎÊÎÂÀß ÈÇÎËßÖÈß ÑÒÅÍ, ÔÓÍÄÀÌÅÍÒÎÂ ÃËÈÍÎÉ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÓÊËÀÄÊÀ ÑËÎß ÌßÒÎÉ ÃËÈÍÛ Ñ ÓÏËÎÒÍÅÍÈÅÌ È ÏÐÈÃÎÒÎÂËÅÍÈÅÌ.
ÈÇÌÅÐÈÒÅËÜ: 1 ÌÇ ÈÇÎËÈÐÓÞÙÅÃÎ ÑËÎß
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-5-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 6.93
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.5
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.52
-------------------------------------------------------------------------------------------------------------------------------
ÃËÈÍÀ (411-0002 ) Ì3 1.15
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.04
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 4.42
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.52
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.46
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.04
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.98
02 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÈÐÏÈ×À
ÒÀÁËÈÖÀ 8-6
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÊÈÐÏÈ×À. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß ÎÒÎÏËÅÍÈß, ÂÅÍÒÈËßÖÈÎÍÍÛÕ È ÄÛÌÎÂÛÕ
ÊÀÍÀËÎÂ Ñ ÐÀÇÄÅËÊÀÌÈ ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ, ÀÐÕÈÒÅÊÒÓÐÍÛÕ È ÊÎÍÑÒÐÓÊÒÈÂÍÛÕ
ÄÅÒÀËÅÉ (ÃÐÀÔÛ 1-8). 03.ÐÀÑØÈÂÊÀ ØÂΠÊËÀÄÊÈ ÍÀÐÓÆÍÛÕ ÑÒÅÍ (ÃÐÀÔÛ 1-6). 04.ÓÑÒÀÍÎÂÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ
ÊÐÅÏËÅÍÈÉ (ÃÐÀÔÀ 9).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÑÒÅÍ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÍÀÐÓÆÍÛÕ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÎÑÒÛÕ ¦ÑÐÅÄÍÅÉ ÑËÎÆÍÎÑÒÈ ¦ÑËÎÆÍÛÕ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦Ñ 4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-6-1 ¦ 8-6-2 ¦ 8-6-3 ¦ 8-6-4 ¦ 8-6-5 ¦ 8-6-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 4.54 4.42 4.76 4.64 5.22 5.1
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.61 0.51 0.62 0.52 0.62 0.52
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.86 1.56 1.87 1.57 1.87 1.57
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.24 0.24
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.25 0.25 0.25 0.25
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ,ÑÈËÈÊÀÒÍÛÉ ÈËÈ (404-9032 ) 1000ØÒ 0.38 0.38 0.384 0.384 0.39 0.39
ÏÓÑÒÎÒÅËÛÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.3 0.3 0.3 0.3 0.3 0.3
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05 0.05 0.05 0.05 0.05 0.05
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.11 3.03 3.42 3.34 3.98 3.9
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.86 1.56 1.87 1.57 1.87 1.57
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.56 0.47 0.56 0.47 0.56 0.47
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.3 0.3 0.3 0.3 0.3 0.3
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.27 4.89 5.59 5.21 6.15 5.77
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-6
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÑÒÅÍ ¦ÇÀÏÎËÍÅÍÈÅ ÊÀÐÊÀÑÎÂ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÂÍÓÒÐÅÍÍÈÕ ¦ÏÐÈßÌÊÎÂ È ÊÀ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦---------------------------¦ÍÀËΠ¦----------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦---------------------------¦ ¦ ¦
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ ¦ ¦
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-6-7 ¦ 8-6-8 ¦ 8-6-9 ¦ 8-6-10 ¦ 8-6-11
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 4.38 4.24 5.95 5.12 4.97
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.62 0.52 0.54 0.7 0.55
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.87 1.59 1.65 2.11 1.66
-------------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0002 ) Ì3 0.24
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 50
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.24 0.24
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.24 0.24
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ,ÑÈËÈÊÀÒÍÛÉ ÈËÈ (404-9032 ) 1000ØÒ 0.38 0.38 0.4 0.4 0.4
ÏÓÑÒÎÒÅËÛÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.19 0.19 1.86 0.66 0.66
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03 0.28 0.1 0.1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.98 2.88 4.07 3.46 3.36
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.87 1.59 1.65 2.11 1.66
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.56 0.48 0.49 0.63 0.5
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.19 0.19 1.86 0.66 0.66
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.04 4.66 7.58 6.23 5.68
ÒÀÁËÈÖÀ 8-7 ÊËÀÄÊÀ ÏÅÐÅÃÎÐÎÄÎÊ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÇÀÃÎÒÎÂÊÀ È ÓÑÒÀÍÎÂÊÀ ÀÐÌÀÒÓÐÛ ÏÐÈ ÊËÀÄÊÅ ÀÐÌÈÐÎÂÀÍÍÛÕ ÏÅÐÅÃÎÐÎÄÎÊ (ÃÐÀÔÛ 1-4). 02.ÊËÀÄÊÀ
ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÊÈÐÏÈ×À.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÏÅÐÅÃÎÐÎÄÎÊ ÇÀ ÂÛ×ÅÒÎÌ ÏÐÎÅÌÎÂ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÀÐÌÈÐÎÂÀÍÍÛÕ ÒÎËÙÈÍÎÉ ¦ÍÅÀÐÌÈÐÎÂÀÍÍÛÕ ÒÎËÙÈ-
¦ ¦ ¦-------------------------------------------¦ÍÎÉ Â 1:2 ÊÈÐÏÈ×À
¦ ¦ ¦Â 1:4 ÊÈÐÏÈ×À ¦Â 1:2 ÊÈÐÏÈ×À ¦
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-7-1 ¦ 8-7-2 ¦ 8-7-3 ¦ 8-7-4 ¦ 8-7-5 ¦ 8-7-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 124 95.3 143 114 121 92.5
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 3.45 3.45 6.35 6.35 6.29 6.29
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 10.48 10.48 19.26 19.26 19.07 19.07
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÊÀÒ ÄËß ÀÐÌÈÐÎÂÀÍÈß Æ/Á 101-1150 Ò 0.06 0.06 0.09 0.09
ÊÎÍÑÒÐÓÊÖÈÉ ÊÐÓÃËÛÉ È
ÏÅÐÈÎÄÈ×ÅÑÊÎÃÎ ÏÐÎÔÈËß,
ÃÎÐß×ÅÊÀÒÀÍÛÉ È ÒÅÐÌÎÌÅÕÀÍÈ×ÅÑÊÈÉ,
ÒÅÐÌÈ×ÅÑÊÈ ÓÏÐÎ×ÅÍÍÛÉ ÊËÀÑÑ À-I,
ÄÈÀÌÅÒÐÎÌ 10 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 2.3 2.3
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.77 0.83 2.3 2.3
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ,ÑÈËÈÊÀÒÍÛÉ ÈËÈ (404-9032 ) 1000ØÒ 2.7 2.94 5 5 5 5
ÏÓÑÒÎÒÅËÛÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 9.47 9.47 9.99 9.99 9.99 9.99
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.42 1.42 1.5 1.5 1.5 1.5
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 86.6 63.4 100 76.8 84 60.8
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 10.48 10.48 19.26 19.26 19.07 19.07
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 3.14 3.14 5.78 5.78 5.72 5.72
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 9.47 9.47 9.99 9.99 9.99 9.99
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 106.55 83.35 129.25 106.05 113.06 89.86
---------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 13.8 13.8 20.7 20.7
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.42 1.42 2.12 2.12
ÒÀÁËÈÖÀ 8-8 ÊËÀÄÊÀ ÈÇ ÊÈÐÏÈ×À ÊÎÍÑÒÐÓÊÖÈÉ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÊÈÐÏÈ×À. 02.ÀÐÌÈÐÎÂÀÍÈÅ ÊÎÍÑÒÐÓÊÖÈÉ (ÃÐÀÔÛ 1,2,5-8). 03.ÓÑÒÐÎÉÑÒÂÎ ËÅÑΠÈ
ÎÏÀËÓÁÊÈ ÄËß ÑÂÎÄÎÂ È ÀÐÎÊ (ÃÐÀÔÀ 9).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÑÒÎËÁÎÂ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÏÐßÌÎÓÃÎËÜÍÛÕ ¦ÊÐÓÃËÛÕ
¦ ¦ ¦-------------------------------------------------------¦
¦ ¦ ¦ÀÐÌÈÐÎÂÀÍÍÛÕ ¦ÍÅÀÐÌÈÐÎÂÀÍÍÛÕ ¦
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-8-1 ¦ 8-8-2 ¦ 8-8-3 ¦ 8-8-4 ¦ 8-8-5
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 7.46 7.33 6.66 6.54 10.4
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.67 0.56 0.67 0.56 0.71
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.04 1.7 2.03 1.7 2.15
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎÂÎËÎÊÀ ÀÐÌÀÒÓÐÍÀß ÈÇ 204-0028 Ò 0.01 0.01 0.01
ÍÈÇÊÎÓÃËÅÐÎÄÈÑÒÎÉ ÑÒÀËÈ ÂÐ-1,
ÄÈÀÌÅÒÐÎÌ, ÌÌ: 3 ÌÌ
ÍÀÄÁÀÂÊÈ Ê ÖÅÍÀÌ ÇÀÃÎÒÎÂÎÊ ÇÀ 204-0032 Ò 0.01 0.01 0.01
ÑÁÎÐÊÓ È ÑÂÀÐÊÓ ÊÀÐÊÀÑÎÂ,ÑÅÒÎÊ:
ÏËÎÑÊÈÕ, ÄÈÀÌÅÒÐÎÌ, ÌÌ: 3 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.22 0.22 0.22 0.22 0.24
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.404 0.404 0.404 0.404 0.45
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.1 0.1 0.1 0.1 0.1
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.02 0.02 0.02 0.02 0.02
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 5.68 5.6 5.13 5.05 8.68
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.04 1.7 2.03 1.7 2.15
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.61 0.51 0.61 0.51 0.64
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.1 0.1 0.1 0.1 0.1
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 7.82 7.4 7.26 6.85 10.93
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.83 6.83 6.83
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.48 0.48 0.48
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-8
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÑÒÎËÁΠÊÐÓÃËÛÕ ¦ÁÅÑÅÄÎÊ, ÏÎÐÒÈÊÎÂ È ÄÐÓÃÈÕ ÄÅÊÎ- ¦ÑÂÎÄÎÂ È ÀÐÎÊ
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ¦ÐÀÒÈÂÍÛÕ ÊÎÍÑÒÐÓÊÖÈÉ ÂÛÑÎÒÎÉ ¦ÍÀÄ ÏÐÎÅÇÄÀÌÈ È
¦ ¦ ¦ ÑÂ.4 Ì ¦---------------------------------¦ÏÐÎÅÌÀÌÈ
¦ ¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-8-6 ¦ 8-8-7 ¦ 8-8-8 ¦ 8-8-9
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 10.3 11.1 11 14
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.6 0.72 0.58 0.59
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.81 2.19 1.76 1.79
-----------------------------------------------------------------------------------------------------------------------------
ÁÐÅÂÍÀ ÄËß ÑÒÐÎÈÒÅËÜÑÒÂÀ 102-0008 Ì3 0.02
ÄËÈÍÎÉ 3-6,5 Ì, ÄÈÀÌÅÒÐÎÌ 14-24 ÑÌ
ÄÎÑÊÈ ÎÁÐÅÇÍÛÅ ÄËÈÍÎÉ 4-6,5 Ì, 102-0061 Ì3 0.04
ØÈÐÈÍÎÉ 75-100 ÌÌ ÒÎËÙÈÍÎÉ 44 ÌÌ È
ÁÎËÅÅ, III ÑÎÐÒÀ
ÏÐÎÂÎËÎÊÀ ÀÐÌÀÒÓÐÍÀß ÈÇ 204-0028 Ò 0.01 0.004 0.004
ÍÈÇÊÎÓÃËÅÐÎÄÈÑÒÎÉ ÑÒÀËÈ ÂÐ-1,
ÄÈÀÌÅÒÐÎÌ, ÌÌ: 3 ÌÌ
ÍÀÄÁÀÂÊÈ Ê ÖÅÍÀÌ ÇÀÃÎÒÎÂÎÊ ÇÀ 204-0032 Ò 0.01 0.004 0.004
ÑÁÎÐÊÓ È ÑÂÀÐÊÓ ÊÀÐÊÀÑÎÂ,ÑÅÒÎÊ:
ÏËÎÑÊÈÕ, ÄÈÀÌÅÒÐÎÌ, ÌÌ: 3 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.24 0.24 0.24 0.24
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.45 0.421 0.421 0.415
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.1 0.1 0.1 0.38
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.02 0.02 0.02 0.06
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 8.62 9.4 9.3 11
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.81 2.19 1.76 1.79
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.54 0.66 0.53 0.54
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.1 0.1 0.1 0.38
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 10.53 11.69 11.16 13.17
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.83 2.73 2.73 4.77
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.48 0.19 0.19 0.59
ÒÀÁËÈÖÀ 8-9 ÑÂÎÄÛ ÖÈËÈÍÄÐÈ×ÅÑÊÈÅ ÒÎËÙÈÍÎÉ Â 1:2 ÊÈÐÏÈ×À
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÊÈÐÏÈ×À. 02.ÇÀÒÈÐÊÀ ÏÎÂÅÐÕÍÎÑÒÈ ÑÂÎÄΠÐÀÑÒÂÎÐÎÌ. 03.ÓÑÒÐÎÉÑÒÂÎ ËÅÑΠÈ
ÎÏÀËÓÁÊÈ ÄËß ÑÂÎÄÎÂ È ÀÐÎÊ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÃÎÐÈÇÎÍÒÀËÜÍÎÉ ÏÐÎÅÊÖÈÈ ÏÅÐÅÊÐÛÒÈß ÈËÈ ÏÎÊÐÛÒÈß
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-9-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 252
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 4.59
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 13.91
-------------------------------------------------------------------------------------------------------------------------------
ÁÐÅÂÍÀ ÄËß ÑÒÐÎÈÒÅËÜÑÒÂÀ 102-0008 Ì3 0.48
ÄËÈÍÎÉ 3-6,5 Ì, ÄÈÀÌÅÒÐÎÌ 14-24 ÑÌ
ÄÎÑÊÈ ÎÁÐÅÇÍÛÅ ÄËÈÍÎÉ 4-6,5 Ì, 102-0061 Ì3 0.98
ØÈÐÈÍÎÉ 75-100 ÌÌ ÒÎËÙÈÍÎÉ 44 ÌÌ È
ÁÎËÅÅ, III ÑÎÐÒÀ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 2.5
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 5.66
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 5.63
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.84
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 150
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 13.91
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 4.17
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 5.63
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 169.54
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 116.41
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 14.48
ÒÀÁËÈÖÀ 8-10 ÊËÀÄÊÀ ÀÐÌÈÐÎÂÀÍÍÛÕ ÑÒÅÍ ÈÇ ÊÈÐÏÈ×À  ÐÀÉÎÍÀÕ Ñ ÑÅÉÑÌÈ×ÍÎÑÒÜÞ 7-8 ÁÀËËÎÂ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÊÈÐÏÈ×À. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß ÎÒÎÏËÅÍÈß, ÂÅÍÒÈËßÖÈÎÍÍÛÕ È ÄÛÌÎÂÛÕ ÊÀÍÀËÎÂ
Ñ ÐÀÇÄÅËÊÀÌÈ ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ, ÀÐÕÈÒÅÊÒÓÐÍÛÕ È ÊÎÍÑÒÐÓÊÒÈÂÍÛÕ ÄÅÒÀËÅÉ.
03.ÐÀÑØÈÂÊÀ ØÂÎÂ ÊËÀÄÊÈ ÍÀÐÓÆÍÛÕ ÑÒÅÍ. 04.ÓÊËÀÄÊÀ ÀÐÌÀÒÓÐÛ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÍÀÐÓÆÍÛÕ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÎÑÒÛÕ ¦ÑÐÅÄÍÅÉ ÑËÎÆÍÎÑÒÈ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-10-1 ¦ 8-10-2 ¦ 8-10-3 ¦ 8-10-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.07 4.94 5.34 5.23
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.61 0.51 0.62 0.52
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.86 1.56 1.87 1.57
-----------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.24 0.24
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.25 0.25
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.38 0.38 0.38 0.38
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03 0.03 0.03
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.48 3.44 3.85 3.81
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.86 1.56 1.87 1.57
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.56 0.47 0.56 0.47
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.55 5.21 5.93 5.59
ÒÀÁËÈÖÀ 8-11 ÐÀÑØÈÂÊÀ ØÂÎÂ ÊËÀÄÊÈ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÐÀÑØÈÂÊÀ ØÂÎÂ ÎÄÍÎÂÐÅÌÅÍÍÎ Ñ ÊËÀÄÊÎÉ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÑÒÅÍ ÁÅÇ ÂÛ×ÅÒÀ ÏÐÎÅÌÎÂ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÊÈÐÏÈ×À ¦ÈÇ ÊÅÐÀÌÈ×ÅÑÊÈÕ È ÌÅËÊÎÁËÎ×ÍÛÕ ÊÀÌÍÅÉ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-11-1 ¦ 8-11-2
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 21.9 14
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 17.3 11.1
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 17.3 11.1
ÒÀÁËÈÖÀ 8-12
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÓÊËÀÄÊÀ ÀÐÌÀÒÓÐÍÛÕ ÑÅÒÎÊ (ÃÐ.1). 02.ÊÐÅÏËÅÍÈÅ ÑÂÎÄΠÑÒÀËÜÍÛÌÈ ÇÀÒ߯ÊÀÌÈ (ÃÐ.2). 03.ÓÑÒÀÍÎÂÊÀ
ÊÎÍÑÒÐÓÊÖÈÉ ÍÀ ÌÅÑÒÎ Ñ ÇÀÊÐÅÏËÅÍÈÅÌ ÈÕ (ÃÐ.3). 04.ÎÊÐÀÑÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÊÎÍÑÒÐÓÊÖÈÉ ÀÑÔÀËÜÒÎÂÛÌ
ËÀÊÎÌ ÇÀ 1 ÐÀÇ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ò ÌÅÒÀËËÈ×ÅÑÊÈÕ ÈÇÄÅËÈÉ
------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÀÐÌÈÐÎÂÀÍÈÅ ÊËÀÄÊÈ ÑÒÅͦÊÐÅÏËÅÍÈÅ ÑÂÎÄΠÑÒÀËÜ-¦ÓÑÒÀÍÎÂÊÀ ÌÅÒÀËËÈ×ÅÑ-
¦ ¦ ¦È ÄÐÓÃÈÕ ÊÎÍÑÒÐÓÊÖÈÉ ¦ÍÛÌÈ ÇÀÒ߯ÊÀÌÈ ¦ÊÈÕ ÐÅØÅÒÎÊ ÏÐÈßÌÊÎÂ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ.¦ 8-12-1 ¦ 8-12-2 ¦ 8-12-3
------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 56.4 32.7 42.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.77 1.55 3.55
------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.34 4.7 10.77
------------------------------------------------------------------------------------------------------------------------------
ÏÎÊÎÂÊÈ ÈÇ ÊÂÀÄÐÀÒÍÛÕ ÇÀÃÎÒÎÂÎÊ 101-0782 Ò 0.06
ÌÀÑÑÎÉ, ÊÃ 1,8
ÌÅÒÀËËÈ×ÅÑÊÈÅ ÈÇÄÅËÈß (201-9014 ) Ò 1 1
ÏÐÎÂÎËÎÊÀ ÀÐÌÀÒÓÐÍÀß ÈÇ ÍÈÇÊÎÓÃËÅ- 204-0028 Ò 1
ÐÎÄÈÑÒÎÉ ÑÒÀËÈ ÂÐ-1, ÄÈÀÌ.,ÌÌ:3 ÌÌ
ÍÀÄÁÀÂÊÈ Ê ÖÅÍÀÌ ÇÀÃÎÒÎÂÎÊ ÇÀ 204-0032 Ò 1
ÑÁÎÐÊÓ È ÑÂÀÐÊÓ ÊÀÐÊÀÑÎÂ,ÑÅÒÎÊ:
ÏËÎÑÊÈÕ, ÄÈÀÌ., ÌÌ: 3 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÎÒÄÅËÎ×ÍÛÅ (402-0036 ) Ì3 0.75
Ò߯ÅËÛÅ ÖÅÌÅÍÒÍÛÅ ÑÎÑÒÀÂÀ 1:3
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 13.24
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 1.99
------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 36.7 26.6 31
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.34 4.7 10.77
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.7 1.41 3.23
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 13.24
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 39.04 31.51 55.01
------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 683 30.18
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 47.7 3.02
03 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ ÊËÀÄÎ×ÍÛÕ
ÒÀÁËÈÖÀ 8-13 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ ÑÒÅÍ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ ÊÀÌÍÅÉ. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß ÎÒÎÏËÅÍÈß, ÂÅÍÒÈËßÖÈÎÍÍÛÕ È ÄÛÌÎÂÛÕ
ÊÀÍÀËÎÂ Ñ ÐÀÇÄÅËÊÀÌÈ ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ, ÀÐÕÈÒÅÊÒÓÐÍÛÕ È ÊÎÍÑÒÐÓÊÒÈÂÍÛÕ
ÄÅÒÀËÅÉ (ÃÐÀÔÛ 1-6). 03.ÐÀÑØÈÂÊÀ ØÂÎÂ ÊËÀÄÊÈ ÍÀÐÓÆÍÛÕ ÑÒÅÍ (ÃÐÀÔÛ 1-6).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÏÐÎÑÒÛÕ ¦ÑÐÅÄÍÅÉ ÑËÎÆÍÎÑÒÈ ¦ÑËÎÆÍÛÕ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-13-1 ¦ 8-13-2 ¦ 8-13-3 ¦ 8-13-4 ¦ 8-13-5 ¦ 8-13-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 3.85 3.73 4.03 3.91 4.45 4.33
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.53 0.43 0.53 0.43 0.53 0.43
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.62 1.31 1.62 1.31 1.62 1.31
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.17 0.17
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.17 0.17 0.17 0.17
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9033 ) 1000ØÒ 0.195 0.195 0.197 0.197 0.202 0.202
ÊËÀÄÎ×ÍÛÅ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.27 0.27 0.27 0.27 0.27 0.27
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.04 0.04 0.04 0.04 0.04 0.04
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.61 2.53 2.85 2.77 3.34 3.26
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.62 1.31 1.62 1.31 1.62 1.31
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.49 0.39 0.49 0.39 0.49 0.39
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.27 0.27 0.27 0.27 0.27 0.27
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 4.5 4.11 4.74 4.35 5.23 4.84
ÒÀÁËÈÖÀ 8-14 ÊËÀÄÊÀ ÏÅÐÅÃÎÐÎÄÎÊ ÒÎËÙÈÍÎÉ 120 ÌÌ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÇÀÃÎÒÎÂÊÀ È ÓÑÒÀÍÎÂÊÀ ÀÐÌÀÒÓÐÛ ÏÐÈ ÊËÀÄÊÅ ÀÐÌÈÐÎÂÀÍÍÛÕ ÏÅÐÅÃÎÐÎÄÎÊ. 02.ÊËÀÄÊÀ ÊÎÍÑÒÐÓÊÖÈÉ ÈÇ
ÊÀÌÍÅÉ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÏÅÐÅÃÎÐÎÄÎÊ ÇÀ ÂÛ×ÅÒÎÌ ÏÐÎÅÌÎÂ
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÀÐÌÈÐÎÂÀÍÍÛÕ ¦ÍÅÀÐÌÈÐÎÂÀÍÍÛÕ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-14-1 ¦ 8-14-2 ¦ 8-14-3 ¦ 8-14-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 125 96.2 103 79.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 5.05 4.89 5.05 4.89
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 15.33 14.84 15.33 14.84
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎÊÀÒ ÄËß ÀÐÌÈÐÎÂÀÍÈß Æ/Á 101-1150 Ò 0.09 0.09
ÊÎÍÑÒÐÓÊÖÈÉ ÊÐÓÃËÛÉ È
ÏÅÐÈÎÄÈ×ÅÑÊÎÃÎ ÏÐÎÔÈËß,
ÃÎÐß×ÅÊÀÒÀÍÛÉ È ÒÅÐÌÎÌÅÕÀÍÈ×ÅÑÊÈÉ,
ÒÅÐÌÈ×ÅÑÊÈ ÓÏÐÎ×ÅÍÍÛÉ ÊËÀÑÑ À-I,
ÄÈÀÌÅÒÐÎÌ 10 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 1.4 1.4
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 1.4 1.4
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9033 ) 1000ØÒ 2.6 2.6 2.6 2.6
ÊËÀÄÎ×ÍÛÅ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 9.59 9.59 9.59 9.59
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.44 1.44 1.44 1.44
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 86.2 66.3 70.2 54
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 15.33 14.84 15.33 14.84
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 4.6 4.45 4.6 4.45
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 9.59 9.59 9.59 9.59
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 111.12 90.73 95.12 78.43
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 20.7 20.7
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 2.12 2.12
04 ÑÒÅÍÛ ÍÀÐÓÆÍÛÅ ÈÇ ÊÈÐÏÈ×À È ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ Ñ ÎÁËÈÖÎÂÊÎÉ ËÈÖÅÂÛÌ
ÊÈÐÏÈ×ÎÌ, ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ÈËÈ ÑÈËÈÊÀÒÍÛÌÈ
ÒÀÁËÈÖÀ 8-15 ÊËÀÄÊÀ ÑÒÅÍ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ Ñ ÎÄÍÎÂÐÅÌÅÍÍÎÉ ÎÁËÈÖÎÂÊÎÉ ÑÒÅÍ, ÏÈËßÑÒÐ È ÎÒÊÎÑÎÂ. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß
ÎÒÎÏËÅÍÈß, ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ È ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ. 03.ÐÀÑØÈÂÊÀ ØÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÊÈÐÏÈ×À Ñ ÎÁËÈÖÎÂÊÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ËÈÖÅÂÛÌ ÊÈÐÏÈ×ÎÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-15-1 ¦ 8-15-2 ¦ 8-15-3 ¦ 8-15-4 ¦ 8-15-5 ¦ 8-15-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 6.41 6.31 5.53 5.5 5.07 4.99
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.56 0.44 0.52 0.39 0.49 0.36
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.7 1.32 1.57 1.18 1.48 1.1
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.23 0.23 0.23 0.23 0.23 0.23
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ,ÑÈËÈÊÀÒÍÛÉ ÈËÈ (404-9032 ) 1000ØÒ 0.21 0.21 0.25 0.25 0.27 0.27
ÏÓÑÒÎÒÅËÛÉ
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9034 ) 1000ØÒ 0.175 0.175 0.13 0.13 0.105 0.105
ËÈÖÅÂÎÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.25 0.25 0.25 0.25 0.25 0.25
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.04 0.04 0.04 0.04 0.04 0.04
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 4.62 4.57 4.01 3.95 3.62 3.56
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.7 1.32 1.57 1.18 1.48 1.1
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.51 0.4 0.47 0.35 0.44 0.33
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.25 0.25 0.25 0.25 0.25 0.25
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 6.57 6.14 5.83 5.38 5.35 4.91
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-15
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÊÀÌÍÅÉ Ñ ÎÁËÈÖÎÂÊÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ËÈÖÅÂÛÌ ÊÈÐÏÈ×ÎÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-15-7 ¦ 8-15-8 ¦ 8-15-9 ¦ 8-15-10 ¦ 8-15-11 ¦ 8-15-12
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.74 5.65 5.45 5.37 4.79 4.72
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.57 0.45 0.53 0.41 0.5 0.39
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.72 1.36 1.62 1.24 1.52 1.17
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.19 0.19 0.19 0.19 0.19 0.19
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9033 ) 1000ØÒ 0.105 0.105 0.129 0.129 0.143 0.143
ÊËÀÄÎ×ÍÛÅ
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9034 ) 1000ØÒ 0.186 0.186 0.138 0.138 0.11 0.11
ËÈÖÅÂÎÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.3 0.3 0.3 0.3 0.3 0.3
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05 0.05 0.05 0.05 0.05 0.05
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 4.16 4.09 4.16 4.1 3.63 3.58
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.72 1.36 1.62 1.24 1.52 1.17
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.52 0.41 0.49 0.37 0.46 0.35
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.3 0.3 0.3 0.3 0.3 0.3
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 6.18 5.75 6.08 5.64 5.45 5.05
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-15
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÊÀÌÍÅÉ Ñ ÎÁËÈÖÎÂÊÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ËÈÖÅÂÛÌÈ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-15-13 ¦ 8-15-14 ¦ 8-15-15 ¦ 8-15-16 ¦ 8-15-17 ¦ 8-15-18
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.1 5.02 4.45 4.38 4.07 4
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.57 0.45 0.53 0.41 0.5 0.37
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.72 1.36 1.62 1.24 1.51 1.13
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.17 0.17 0.17 0.17 0.17 0.17
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9033 ) 1000ØÒ 0.105 0.105 0.129 0.129 0.143 0.143
ÊËÀÄÎ×ÍÛÅ
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9080 ) 1000ØÒ 0.093 0.093 0.069 0.069 0.055 0.055
ËÈÖÅÂÛÅ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.27 0.27 0.27 0.27 0.27 0.27
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.04 0.04 0.04 0.04 0.04 0.04
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.71 3.65 3.22 3.17 2.9 2.85
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.72 1.36 1.62 1.24 1.51 1.13
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.52 0.41 0.49 0.37 0.45 0.34
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.27 0.27 0.27 0.27 0.27 0.27
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.7 5.28 5.11 4.68 4.68 4.25
05 Ó×ÀÑÒÊÈ ÑÒÅÍ (ÊÀÐÍÈÇÛ,ÏÎßÑÊÈ È Ò.Ï) ÈÇ ÊÈÐÏÈ×À È ÊÀÌÍÅÉ ÊÅÐÀÌÈ×ÅÑÊÈÕ ÈËÈ ÑÈËÈÊÀÒÍÛÕ Ñ
ÎÁËÈÖÎÂÊÎÉ ÊÈÐÏÈ×ÎÌ ËÈÖÅÂÛÌ ÏÐÎÔÈËÜÍÛÌ ÈËÈ ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ËÈÖÅÂÛÌÈ ÏÐÎÔÈËÜÍÛÌÈ
ÒÀÁËÈÖÀ 8-16 ÊËÀÄÊÀ Ó×ÀÑÒÊΠÑÒÅÍ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ Ñ ÓÑÒÐÎÉÑÒÂÎÌ ÂÛÍÎÑÎÂ È ÎÁËÈÖÎÂÊÎÉ ÏÎ ØÀÁËÎÍÓ. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ, ÁÎÐÎÇÄ,
ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ. 03.ÓÑÒÐÎÉÑÒÂÎ ÑËÈÂÎÂ. 04.ÐÀÑØÈÂÊÀ ØÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÊÈÐÏÈ×À
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦Ñ ÎÁËÈÖÎÂÊÎÉ ÊÈÐÏÈ×ÎÌ ËÈÖÅÂÛÌ ÏÐÎÔÈËÜÍÛÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ ÑÒÅÍ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÅÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-16-1 ¦ 8-16-2 ¦ 8-16-3 ¦ 8-16-4 ¦ 8-16-5 ¦ 8-16-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 9.81 9.67 7.39 7.29 6.37 6.27
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.53 0.41 0.53 0.41 0.49 0.37
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.61 1.23 1.61 1.23 1.49 1.11
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.23 0.23 0.23 0.23 0.23 0.23
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ,ÑÈËÈÊÀÒÍÛÉ ÈËÈ (404-9032 ) 1000ØÒ 0.157 0.157 0.215 0.215 0.247 0.247
ÏÓÑÒÎÒÅËÛÉ
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ËÈÖÅÂÎÉ (404-9035 ) 1000ØÒ 0.233 0.233 0.175 0.175 0.143 0.143
ÏÐÎÔÈËÜÍÛÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.09 0.09 0.09 0.09 0.09 0.09
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01 0.01 0.01 0.01 0.01 0.01
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 7.69 7.6 5.7 5.65 4.94 4.89
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.61 1.23 1.61 1.23 1.49 1.11
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.48 0.37 0.48 0.37 0.45 0.33
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.09 0.09 0.09 0.09 0.09 0.09
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 9.39 8.92 7.4 6.97 6.52 6.09
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-16
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÊÀÌÍÅÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦Ñ ÎÁËÈÖÎÂÊÎÉ ÊÈÐÏÈ×ÎÌ ËÈÖÅÂÛÌ ÏÐÎÔÈËÜÍÛÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ ÑÒÅÍ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÅÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-16-7 ¦ 8-16-8 ¦ 8-16-9 ¦ 8-16-10 ¦ 8-16-11 ¦ 8-16-12
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 8.44 8.3 6.24 6.14 5.4 5.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.53 0.41 0.53 0.41 0.5 0.37
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.62 1.24 1.62 1.24 1.51 1.13
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.19 0.19 0.18 0.18 0.18 0.18
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9033 ) 1000ØÒ 0.08 0.08 0.109 0.109 0.125 0.125
ÊËÀÄÎ×ÍÛÅ
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ËÈÖÅÂÎÉ (404-9035 ) 1000ØÒ 0.233 0.233 0.175 0.175 0.143 0.143
ÏÐÎÔÈËÜÍÛÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.09 0.09 0.09 0.09 0.09 0.09
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01 0.01 0.01 0.01 0.01 0.01
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 6.61 6.52 4.84 4.79 4.17 4.12
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.62 1.24 1.62 1.24 1.51 1.13
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.49 0.37 0.49 0.37 0.45 0.34
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.09 0.09 0.09 0.09 0.09 0.09
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 8.32 7.85 6.55 6.12 5.77 5.34
ÒÀÁËÈÖÀ 8-17 ÊËÀÄÊÀ ÈÇ ÊÀÌÍÅÉ Ñ ÎÁËÈÖÎÂÊÎÉ ÊÀÌÍßÌÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ËÈÖÅÂÛÌÈ ÏÐÎÔÈËÜÍÛÌÈ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ, Ñ ÓÑÒÐÎÉÑÒÂÎÌ ÂÛÍÎÑÎÂ È ÎÁËÈÖÎÂÊÎÉ ÏÎ ØÀÁËÎÍÓ. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ, ÁÎÐÎÇÄ,
ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ. 03.ÓÑÒÐÎÉÑÒÂÎ ÑËÈÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ ÑÒÅÍ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-17-1 ¦ 8-17-2 ¦ 8-17-3 ¦ 8-17-4 ¦ 8-17-5 ¦ 8-17-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 8.44 8.3 6.24 6.14 5.4 5.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.53 0.41 0.53 0.41 0.5 0.37
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.62 1.24 1.62 1.24 1.51 1.13
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 0.19 0.19 0.18 0.18 0.18 0.18
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ÈËÈ ÑÈËÈÊÀÒÍÛÅ (404-9033 ) 1000ØÒ 0.08 0.08 0.109 0.109 0.125 0.125
ÊËÀÄÎ×ÍÛÅ
ÊÀÌÍÈ ÊÅÐÀÌÈ×ÅÑÊÈÅ ËÈÖÅÂÛÅ (404-9090 ) 1000ØÒ 0.118 0.118 0.089 0.089 0.073 0.073
ÏÐÎÔÈËÜÍÛÅ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.09 0.09 0.09 0.09 0.09 0.09
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01 0.01 0.01 0.01 0.01 0.01
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 6.61 6.52 4.84 4.79 4.17 4.12
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.62 1.24 1.62 1.24 1.51 1.13
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.49 0.37 0.49 0.37 0.45 0.34
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.09 0.09 0.09 0.09 0.09 0.09
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 8.32 7.85 6.55 6.12 5.77 5.34
06 ÑÒÅÍÛ ÍÀÐÓÆÍÛÅ ÈÇ ÊÈÐÏÈ×À Ñ ÎÁËÈÖÎÂÊÎÉ Â ÏÐÎÖÅÑÑÅ ÊËÀÄÊÈ ÊÅÐÀÌÈ×ÅÑÊÈÌÈ ÏËÈÒÀÌÈ
ÒÀÁËÈÖÀ 8-18
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ Ñ ÎÄÍÎÂÐÅÌÅÍÍÎÉ ÎÁËÈÖÎÂÊÎÉ ÑÒÅÍ, ÏÈËßÑÒÐ È ÎÒÊÎÑÎÂ. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß ÎÒÎÏËÅÍÈß,
ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ. 03.ÐÀÑØÈÂÊÀ ØÂÎÂ È ÏÐÎÌÛÂÊÀ ÎÁËÈÖÎÂÊÈ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÑÒÅÍ (ÇÀ ÂÛ×ÅÒÎÌ ÏÐÎÅÌÎÂ)
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ ÑÒÅÍ ¦ÍÀ ÊÀÆÄÛÅ 120 ÌÌ ÈÇÌÅÍÅÍÈÉ ÒÎËÙÈ-
¦ ¦ ¦---------------------------------¦ÍÛ ÊËÀÄÊÈ ÄÎÁÀÂËßÒÜ ÈËÈ ÂÛ×ÈÒÀÒÜ
¦ ¦ ¦ÒÎËÙÈÍÎÉ Â 2 ÊÈÐÏÈ×À Ñ ÎÁËÈÖÎÂÊÎɦ
¦ ¦ ¦ ÊÅÐÀÌÈ×ÅÑÊÎÉ ÏËÈÒÊÎÉ ¦
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-18-1 ¦ 8-18-2 ¦ 8-18-3 ¦ 8-18-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 570 558 36.2 35.9
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 34.85 28.16 4.97 4.89
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 105.72 85.41 15.09 14.83
-----------------------------------------------------------------------------------------------------------------------------
ÏËÈÒÛ ÊÅÐÀÌÈ×ÅÑÊÈÅ (101-9050 ) Ì2 101.5 101.5
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0013 ) Ì3 13.4 13.4 3 3
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ,ÑÈËÈÊÀÒÍÛÉ ÈËÈ (404-9032 ) 1000ØÒ 19.4 19.4 4.85 4.95
ÏÓÑÒÎÒÅËÛÉ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 16.67 16.67 3.74 3.74
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 2.5 2.5 0.56 0.56
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 432 423 25.1 24.9
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 105.72 85.41 15.09 14.83
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 31.72 25.62 4.53 4.45
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 16.67 16.67 3.74 3.74
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 554.39 525.08 43.93 43.47
07 ÑÒÅÍÛ ÍÀÐÓÆÍÛÅ È ÂÍÓÒÐÅÍÍÈÅ ÊÈÐÏÈ×ÍÛÅ ÎÁËÅÃ×ÅÍÍÛÕ ÊÎÍÑÒÐÓÊÖÈÉ
ÒÀÁËÈÖÀ 8-19 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ È ÂÍÓÒÐÅÍÍÈÕ ÑÒÅÍ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ ÈÇ ÊÈÐÏÈ×À Ñ ÇÀÏÎËÍÅÍÈÅÌ ÏÓÑÒÎÒ ÊËÀÄÊÈ ËÅÃÊÈÌ ÁÅÒÎÍÎÌ (ÃÐÀÔÛ 1-6) ÈËÈ ÇÀÑÛÏÍÛÌÈ
ÌÀÒÅÐÈÀËÀÌÈ (ÃÐÀÔÛ 7-12). 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß ÎÒÎÏËÅÍÈß, ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ
È ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ. 03.ÐÀÑØÈÂÊÀ ØÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ ÊÎÍÑÒÐÓÊÖÈÉ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊÈÐÏÈ×ÍÎ-ÁÅÒÎÍÍÛÕ Ñ ÇÀÏÎËÍÅÍÈÅÌ ËÅÃÊÈÌ ÁÅÒÎÍÎÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-19-1 ¦ 8-19-2 ¦ 8-19-3 ¦ 8-19-4 ¦ 8-19-5 ¦ 8-19-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.1 4.5 4.27 4.18 3.53 3.46
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.57 0.45 0.53 0.41 0.49 0.36
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.72 1.35 1.61 1.23 1.48 1.1
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.18 0.18 0.14 0.14 0.11 0.11
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.352 0.352 0.263 0.263 0.209 0.209
ÇÀÏÎËÍÈÒÅËÜ (411-9370 ) Ì3 0.14 0.14 0.37 0.37 0.51 0.51
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.45 0.45 0.43 0.43 0.38 0.38
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.07 0.07 0.06 0.06 0.06 0.06
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.77 3.7 3 2.94 2.37 2.32
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.72 1.35 1.61 1.23 1.48 1.1
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.52 0.41 0.48 0.37 0.44 0.33
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.45 0.45 0.43 0.43 0.38 0.38
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.94 5.5 5.04 4.6 4.23 3.8
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-19
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊÈÐÏÈ×ÍÛÕ ÊÎËÎÄÖÅÂÛÕ Ñ ÇÀÏÎËÍÅÍÈÅÌ ÇÀÑÛÏÍÛÌÈ ÌÀÒÅÐÈÀËÀÌÈ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-19-7 ¦ 8-19-8 ¦ 8-19-9 ¦ 8-19-10 ¦ 8-19-11 ¦ 8-19-12
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 6.85 6.74 5.55 5.46 4.91 4.81
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.67 0.55 0.65 0.53 0.63 0.51
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.03 1.68 1.98 1.61 1.91 1.55
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.11 0.11 0.08 0.08 0.07 0.07
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.318 0.318 0.237 0.237 0.189 0.189
ÇÀÏÎËÍÈÒÅËÜ (411-9370 ) Ì3 0.31 0.31 0.46 0.46 0.55 0.55
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.45 0.45 0.43 0.43 0.38 0.38
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.07 0.07 0.06 0.06 0.06 0.06
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 5.07 4.99 4.07 4 3.51 3.44
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.03 1.68 1.98 1.61 1.91 1.55
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.61 0.5 0.59 0.48 0.57 0.47
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.45 0.45 0.43 0.43 0.38 0.38
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 7.55 7.12 6.48 6.04 5.8 5.37
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-19
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊÈÐÏÈ×ÍÛÕ Ñ ÂÅÐÒÈÊÀËÜÍÛÌÈ ÏÎÏÅÐÅ×ÍÛÌÈ ÑÒÅÍÊÀÌÈ È ÓÇËÀÌÈ ÆÅÑÒÊÎÑÒÈ
¦ ¦ ¦
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦Ñ ÇÀÏÎËÍÅÍÈÅÌ ÇÀÑÛÏÍÛÌÈ ÌÀÒÅÐÈÀËÀÌÈ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÒÎËÙÈÍÎÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ ¦640 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-19-13 ¦ 8-19-14 ¦ 8-19-15 ¦ 8-19-16 ¦ 8-19-17 ¦ 8-19-18
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 6.36 6.26 5.19 5.09 4.61 4.52
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.69 0.56 0.66 0.53 0.63 0.51
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.08 1.7 2 1.62 1.91 1.55
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.14 0.14 0.12 0.12 0.11 0.11
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.329 0.329 0.245 0.24 0.195 0.195
ÇÀÏÎËÍÈÒÅËÜ (411-9370 ) Ì3 0.3 0.3 0.44 0.44 0.53 0.53
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.73 0.73 0.73 0.73 0.69 0.69
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.11 0.11 0.11 0.11 0.1 0.1
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 4.7 4.63 3.8 3.73 3.3 3.23
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.08 1.7 2 1.62 1.91 1.55
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.62 0.51 0.6 0.49 0.57 0.47
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.73 0.73 0.73 0.73 0.69 0.69
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 7.51 7.06 6.53 6.08 5.9 5.47
ÒÀÁËÈÖÀ 8-20 ÊËÀÄÊÀ ÍÀÐÓÆÍÛÕ È ÂÍÓÒÐÅÍÍÈÕ ÊÈÐÏÈ×ÍÛÕ ÑÒÅÍ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ ÈÇ ÊÈÐÏÈ×À. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÄËß ÎÒÎÏËÅÍÈß, ÁÎÐÎÇÄ, ÎÑÀÄÎ×ÍÛÕ È ÒÅÌÏÅÐÀÒÓÐÍÛÕ ØÂÎÂ
È ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ. 03.ÈÇÎËßÖÈß ÑÒÅÍ Ñ ÂÍÓÒÐÅÍÍÅÉ ÑÒÎÐÎÍÛ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÌÈ ÏËÈÒÀÌÈ (ÂÏËÎÒÍÓÞ
Ê ÑÒÅÍÅ ÈËÈ Ñ ÂÎÇÄÓØÍÎÉ ÏÐÎÑËÎÉÊÎÉ) Ñ ÓÑÒÀÍÎÂÊÎÉ ÈÕ ÍÀ ÐÀÑÒÂÎÐÅ È ÏÐÈÌÎÐÀÆÈÂÀÍÈÅÌ Ê ÑÒÅÍÅ ÍÀ ÌÀÐÊÀÕ
È ËÅÍÒÎ×ÍÛÕ ÌÀßÊÀÕ (ÃÐÀÔÛ 3-8). 04.ÐÀÑØÈÂÊÀ ØÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Ñ ÂÎÇÄÓØÍÎÉ ÏÐÎÑËÎÉÊÎÉ ¦Ñ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÌÈ ÏËÈÒÀÌÈ
¦ ¦ ¦ ¦ÎÁÙÅÉ ÒÎËÙÈÍÎÉ
¦ ¦ ¦ ¦----------------------------------
¦ ¦ ¦ ¦250 ÌÌ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-20-1 ¦ 8-20-2 ¦ 8-20-3 ¦ 8-20-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.67 5.56 8.87 8.73
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.5 0.39 0.79 0.67
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.52 1.17 2.4 2.02
-----------------------------------------------------------------------------------------------------------------------------
ÏËÈÒÛ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÅ (104-9090 ) Ì2 4.12 4.12
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.21 0.21 0.24 0.24
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.37 0.37 0.408 0.408
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.3 0.3 1.08 1.08
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05 0.05 0.16 0.16
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 4.13 4.05 6.4 6.3
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.52 1.17 2.4 2.02
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.46 0.35 0.72 0.61
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.3 0.3 1.08 1.08
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.95 5.52 9.88 9.4
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-20
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Ñ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÌÈ ÏËÈÒÀÌÈ ÎÁÙÅÉ ÒÎËÙÈÍÎÉ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦380 ÌÌ ¦510 ÌÌ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-20-5 ¦ 8-20-6 ¦ 8-20-7 ¦ 8-20-8
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 7.12 7.01 6.04 5.94
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.68 0.56 0.65 0.52
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.07 1.69 1.97 1.59
-----------------------------------------------------------------------------------------------------------------------------
ÏËÈÒÛ ÒÅÏËÎÈÇÎËßÖÈÎÍÍÛÅ (104-9090 ) Ì2 2.71 2.71 2.02 2.02
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.25 0.25 0.25 0.25
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.403 0.403 0.4 0.4
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.79 0.79 0.55 0.55
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.12 0.12 0.08 0.08
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 5.13 5.05 4.32 4.24
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.07 1.69 1.97 1.59
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.62 0.51 0.59 0.48
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.79 0.79 0.55 0.55
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 7.99 7.53 6.84 6.38
08 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÐÓÏÍÛÕ ÈÇÂÅÑÒÍßÊÎÂÛÕ ÁËÎÊÎÂ
ÒÀÁËÈÖÀ 8-21 ÊËÀÄÊÀ ÈÇ ÊÐÓÏÍÛÕ ÈÇÂÅÑÒÍßÊÎÂÛÕ ÁËÎÊÎÂ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÓÑÒÀÍÎÂÊÀ ÁËÎÊÎÂ Ñ ÏÎÑÒÀÍÎÂÊÎÉ ÊÐÅÏËÅÍÈÉ. 02.ÇÀÄÅËÊÀ È ÐÀÑØÈÂÊÀ ØÂÎÂ. 03.ÑÎÐÒÈÐÎÂÊÀ ÁËÎÊÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ ÁËÎÊÎÂ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÌÀÑÑÎÉ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÄÎ 0,5 Ò ¦ÁÎËÅÅ 0,5 Ò
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-21-1 ¦ 8-21-2
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 4.02 2.77
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 1.57 0.93
-------------------------------------------------------------------------------------------------------------------------------
ÊÐÀÍÛ ÁÀØÅÍÍÛÅ ÏÐÈ ÐÀÁÎÒÅ ÍÀ 020128 Ì-×ÀÑ 0.85 0.44
ÄÐÓÃÈÕ ÂÈÄÀÕ ÑÒÐÎÈÒÅËÜÑÒÂÀ 5 Ò
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.19 1.48
-------------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0011 ) Ì3 0.04 0.03
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 10
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.03 0.02
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÁËÎÊÈ (411-9021 ) Ì3 0.93 0.95
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.86 2.06
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 6.89 3.91
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 1.65 0.95
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 9.96 6.18
09 ÊÎÍÑÒÐÓÊÖÈÈ ÈÇ ÊÀÌÍÅÉ ËÅÃÊÎÁÅÒÎÍÍÛÕ
ÒÀÁËÈÖÀ 8-22
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ ÈÇ ËÅÃÊÎÁÅÒÎÍÍÛÕ ÊÀÌÍÅÉ (ÃÐÀÔÛ 1, 2). 02.ÇÀÏÎËÍÅÍÈÅ ÊÀÐÊÀÑÎÂ È ÔÀÕÂÅÐÊÎÂ (ÃÐÀÔÛ 3, 4)
03.ÊËÀÄÊÀ ÑÒÅÍ ÈÇ ÊÀÌÍÅÉ Ñ ÎÄÍÎÂÐÅÌÅÍÍÎÉ ÎÁËÈÖÎÂÊÎÉ ÑÒÅÍ, ÏÈËßÑÒÐ È ÎÒÊÎÑΠÊÈÐÏÈ×ÎÌ (ÃÐÀÔÛ 5-10)
04.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÎÒÎÏËÅÍÈß È ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ. 05.ÓÑÒÀÍÎÂÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÑÂßÇÅÉ
(ÃÐÀÔÛ 5-10). 06.ÇÀÑÛÏÊÀ ÏÓÑÒÎÒ Â ÊÀÌÍßÕ (ÃÐÀÔÀ 11). 07.ÐÀÑØÈÂÊÀ ØÂÎÂ (ÃÐÀÔÛ 1-10).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
---------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÈÇ ËÅÃÊÎÁÅÒÎÍÍÛÕ ÊÀÌÍÅÉ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÁÅÇ ÎÁËÈÖÎÂÊÈ ¦Ñ ÎÁËÈÖÎÂÊÎÉ Â ÏÐÎÖÅÑ
¦ ¦ ¦-------------------------------------------¦ÑÅ ÊËÀÄÊÈ ÊÈÐÏÈ×ÎÌ
¦ ¦ ¦ÑÒÅÍ ¦ÇÀÏÎËÍÅÍÈÉ ÊÀÐÊÀÑΠ¦( 1:2 ÊÈÐÏÈ×À) ÑÒÅÍ
¦ ¦ ¦ ¦È ÔÀÕÂÅÐÊΠ¦ ÒÎËÙÈÍÎÉ
¦ ¦ ¦ ¦ ¦----------------------
¦ ¦ ¦ ¦ ¦320 ÌÌ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-22-1 ¦ 8-22-2 ¦ 8-22-3 ¦ 8-22-4 ¦ 8-22-5 ¦ 8-22-6
---------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 3.72 3.56 3.07 2.91 4.79 4.58
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.68 0.53 0.58 0.43 0.8 0.65
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.07 1.6 1.77 1.3 2.44 1.97
---------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.11 0.11 0.11 0.11 0.15 0.15
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÀÌÍÈ ËÅÃÊÎÁÅÒÎÍÍÛÅ (403-9210 ) Ì3 0.92 0.92 0.92 0.92 0.55 0.55
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.16 0.16
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.27 0.27 0.27 0.27 0.38 0.38
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.04 0.04 0.04 0.04 0.06 0.06
---------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.64 2.53 2.05 2.01 3.52 3.36
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.07 1.6 1.77 1.3 2.44 1.97
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.62 0.48 0.53 0.39 0.73 0.59
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.27 0.27 0.27 0.27 0.38 0.38
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 4.98 4.4 4.09 3.58 6.34 5.71
---------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-22
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÈÇ ËÅÃÊÎÁÅÒÎÍÍÛÕ ÊÀÌÍÅÉ ¦ÇÀÑÛÏÊÀ
¦ ¦ ¦-------------------------------------------------------¦ÏÓÑÒÎÒ Â
¦ ¦ ¦Ñ ÎÁËÈÖÎÂÊÎÉ Â ÏÐÎÖÅÑÑÅ ÊËÀÄÊÈ ÊÈÐÏÈ×ÎÌ ( 1:2 ÊÈÐÏÈ×À)¦ÊÀÌÍßÕ
¦ ¦ ¦ÑÒÅÍ ÒÎËÙÈÍÎÉ ¦
¦ ¦ ¦-------------------------------------------------------¦
¦ ¦ ¦520 ÌÌ ¦720 ÌÌ ¦
¦ ¦ ¦-------------------------------------------------------¦
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ ¦
¦ ¦ ¦-------------------------------------------------------¦
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-22-7 ¦ 8-22-8 ¦ 8-22-9 ¦ 8-22-10 ¦ 8-22-11
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 4.08 3.81 3.49 3.29 1.22
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.75 0.59 0.77 0.61 0.19
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.27 1.79 2.33 1.86 0.59
-------------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.14 0.14 0.14 0.14
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÀÌÍÈ ËÅÃÊÎÁÅÒÎÍÍÛÅ (403-9210 ) Ì3 0.68 0.68 0.74 0.74
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.1 0.1 0.07 0.07
ÇÀÏÎËÍÈÒÅËÜ (411-9370 ) Ì3 0.25
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.33 0.33 0.31 0.31
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05 0.05 0.05 0.05
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.98 2.67 2.55 2.4 0.87
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.27 1.79 2.33 1.86 0.59
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.68 0.54 0.7 0.56 0.18
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.33 0.33 0.31 0.31
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 5.58 4.79 5.19 4.57 1.46
10 ÑÒÅÍÛ È ÏÅÐÅÃÎÐÎÄÊÈ ÈÇ ÊÀÌÍÅÉ ÈÇÂÅÑÒÊÎÂÛÕ È ÒÓÔÎÂÛÕ
ÒÀÁËÈÖÀ 8-23
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÑÒÅÍ È ÏÅÐÅÃÎÐÎÄÎÊ. 02.ÓÑÒÐÎÉÑÒÂÎ ÍÈØ ÎÒÎÏËÅÍÈß È ÀÐÕÈÒÅÊÒÓÐÍÛÕ ÄÅÒÀËÅÉ. 03.ÏÐÈÒÅÑÊÀ ÊÀÌÍÅÉ.
04.ÎÒÄÅËÊÀ ÏÎÂÅÐÕÍÎÑÒÈ ×ÈÑÒÎÉ ÊËÀÄÊÈ(ÃÐÀÔÀ 5, 6). 05.ÐÀÑØÈÂÊÀ ØÂΠ(ÃÐÀÔÛ 3-6, 13, 14).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÈÇ ÈÇÂÅÑÒÍßÊÀ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÑÒÅÍ ¦ÏÅÐÅÃÎÐÎ-
¦ ¦ ¦-----------------------------------------------------------¦ÄÎÊ ÍÅÀÐ-
¦ ¦ ¦ÎÁÛ×ÍÀß ¦ÐßÄÎÂÀß ¦×ÈÑÒÀß ¦ÌÈÐÎÂÀÍ-
¦ ¦ ¦-----------------------------------------------------------¦ÍÛÕ ÈÇ
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ ¦ÏËÈÒ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-23-1 ¦ 8-23-2 ¦ 8-23-3 ¦ 8-23-4 ¦ 8-23-5 ¦ 8-23-6 ¦ 8-23-7
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 3.13 3.04 4.1 3.98 5.56 5.45 7.77
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.57 0.46 0.59 0.47 0.56 0.45 0.45
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.72 1.39 1.78 1.44 1.69 1.35 1.35
-------------------------------------------------------------------------------------------------------------------------------
ÁÐÓÑÊÈ ÎÁÐÅÇÍÛÅ ÄËÈÍÎÉ 4-6,5 Ì, 102-0025 Ì3 0.06
ØÈÐÈÍÎÉ 75-100 ÌÌ, ÒÎËÙÈÍÎÉ
40-75 ÌÌ III ÑÎÐÒÀ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0011 ) Ì3 0.1 0.1 0.07 0.07 0.07 0.07 0.04
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 10
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.07 0.07 0.04 0.04 0.04 0.04 0.02
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.003 0.003
ÊÀÌÅÍÜ (408-9012 ) Ì3 0.9 0.9 0.98 0.98 0.98 0.98
ÏËÈÒÛ ÈÇ ÊÀÌÍß-ÈÇÂÅÑÒÍßÊÀ (411-9150 ) Ì3 0.91
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21 0.21 0.21 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03 0.03 0.03 0.03 0.03 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.03 1.97 2.68 2.6 4.11 4.02 5.26
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.72 1.39 1.78 1.44 1.69 1.35 1.35
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.52 0.42 0.53 0.43 0.51 0.41 0.41
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21 0.21 0.21 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 3.96 3.57 4.67 4.25 6.01 5.58 6.82
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.42
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.66
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-23
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊËÀÄÊÀ ÈÇ ÈÇÂÅÑÒÍßÊÀ ¦ÊËÀÄÊÀ ÑÒÅÍ ÈÇ ÒÓÔÀ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÏÅÐÅÃÎÐÎ-¦ÑÒÅÍ Ñ ÎÁËÈÖÎÂÊÎÉ ¦ÎÁÛ×ÍÀß ÈÇ ÃÐÓÁÎÎÁ=¦×ÈÑÒÀß ÈÇ ÊÀÌÍÅÉ
¦ ¦ ¦ÄÎÊ ÍÅÀÐ-¦ÊÈÐÏÈ×ÎÌ ÒÎËÙÈÍÎÉ ¦ÐÀÁÎÒÀÍÍÛÕ ÊÀÌÍÅÉ ¦ÏÐÀÂÈËÜÍÎÉ ÔÎÐÌÛ
¦ ¦ ¦ÌÈÐÎÂÀÍ- ¦520 ÌÌ ¦----------------------------------------
¦ ¦ ¦ÍÛÕ ÈÇ ¦-------------------¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦ÏËÈÒ ¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ ¦---------¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ ¦ ¦ ¦
¦ ¦ ¦ÑÂ.4 Ì ¦ ¦ ¦ ¦ ¦ ¦
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-23-8 ¦ 8-23-9 ¦ 8-23-10 ¦ 8-23-11 ¦ 8-23-12 ¦ 8-23-13 ¦ 8-23-14
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 7.63 4.9 4.75 4.81 4.71 5.11 4.97
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.34 0.54 0.43 0.6 0.47 0.62 0.49
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.02 1.65 1.3 1.81 1.43 1.87 1.49
-------------------------------------------------------------------------------------------------------------------------------
ÁÐÓÑÊÈ ÎÁÐÅÇÍÛÅ ÄËÈÍÎÉ 4-6,5 Ì, 102-0025 Ì3 0.06
ØÈÐÈÍÎÉ 75-100 ÌÌ, ÒÎËÙÈÍÎÉ
40-75 ÌÌ III ÑÎÐÒÀ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0011 ) Ì3 0.04 0.13 0.13 0.11 0.11
ÖÅÌÅÍÒÍÎ-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 10
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.02 0.16 0.16 0.09 0.09 0.07 0.07
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ ÈËÈ ÑÈËÈÊÀÒÍÛÉ (404-9036 ) 1000ØÒ 0.16 0.16
ÊÀÌÅÍÜ (408-9012 ) Ì3 0.55 0.55 0.72 0.72 0.92 0.92
ÏËÈÒÛ ÈÇ ÊÀÌÍß-ÈÇÂÅÑÒÍßÊÀ (411-9150 ) Ì3 0.91
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 2.1 2.1 0.4 0.4
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03 0.03 0.32 0.32 0.06 0.06
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 5.17 3.37 3.27 3.3 3.23 3.98 3.87
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.02 1.65 1.3 1.81 1.43 1.87 1.49
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.31 0.49 0.39 0.54 0.43 0.56 0.45
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 2.1 2.1 0.4 0.4
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 6.4 5.23 4.78 7.21 6.76 6.25 5.76
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.42
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.66
11 ÏÅÐÅÃÎÐÎÄÊÈ
ÒÀÁËÈÖÀ 8-24 ÓÑÒÀÍÎÂÊÀ ÏÅÐÅÃÎÐÎÄÎÊ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÂÛÐÀÂÍÈÂÀÍÈÅ ÃÎÒÎÂÎÃÎ ÎÑÍÎÂÀÍÈß ÐÀÑÒÂÎÐÎÌ. 02.ÓÑÒÀÍÎÂÊÀ ÏËÈÒ È ÊÀÐÊÀÑÎÂ (ÃÐÀÔÛ 1-8).
03.ÏÎÑÒÀÍÎÂÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÊÐÅÏËÅÍÈÉ. 04.ÇÀÄÅËÊÀ ØÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÏÅÐÅÃÎÐÎÄÎÊ (ÇÀ ÂÛ×ÅÒÎÌ ÏÐÎÅÌÎÂ)
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ÃÈÏÑÎÂÛÕ ÏËÈÒ Â
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦1 ÑËÎÉ ¦2 ÑËÎß
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-24-1 ¦ 8-24-2 ¦ 8-24-3 ¦ 8-24-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 84.2 81.7 152 147
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 4.75 4.75 10.85 10.85
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 14.41 14.41 32.92 32.92
-----------------------------------------------------------------------------------------------------------------------------
ÃÈÏÑÎÂÛÅ Â߯ÓÙÈÅ Ã-3 101-0219 Ò 0.57 0.57 2.03 2.03
ÏÎÊÎÂÊÈ ÈÇ ÊÂÀÄÐÀÒÍÛÕ ÇÀÃÎÒÎÂÎÊ 101-0782 Ò 0.008 0.008 0.008 0.008
ÌÀÑÑÎÉ, ÊÃ 1,8
ÏÐÎÊÀÒ ÄËß ÀÐÌÈÐÎÂÀÍÈß Æ/Á 101-1150 Ò 0.013 0.013 0.026 0.026
ÊÎÍÑÒÐÓÊÖÈÉ ÊÐÓÃËÛÉ È
ÏÅÐÈÎÄÈ×ÅÑÊÎÃÎ ÏÐÎÔÈËß,
ÃÎÐß×ÅÊÀÒÀÍÛÉ È ÒÅÐÌÎÌÅÕÀÍÈ×ÅÑÊÈÉ,
ÒÅÐÌÈ×ÅÑÊÈ ÓÏÐÎ×ÅÍÍÛÉ ÊËÀÑÑ À-I,
ÄÈÀÌÅÒÐÎÌ 10 ÌÌ
ÁÐÓÑÊÈ ÎÁÐÅÇÍÛÅ ÄËÈÍÎÉ 4-6,5 Ì, 102-0025 Ì3 0.1 0.1 0.2 0.2
ØÈÐÈÍÎÉ 75-100 ÌÌ, ÒÎËÙÈÍÎÉ
40-75 ÌÌ III ÑÎÐÒÀ
ÏËÈÒÛ ÒÎËÙÈÍÎÉ ÄÎ 100 ÌÌ (403-9094 ) Ì2 91 91 182 182
ÏÅÑÎÊ ÄËß ÑÒÐÎÈÒÅËÜÍÛÕ ÐÀÁÎÒ (408-9040 ) Ì3 0.6 0.6 2.1 2.1
ÏÐÈÐÎÄÍÛÉ
ÒÎËÜ ÒÂÊ-350 610-1070 Ì2 6 6 12 12
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03 0.03 0.03
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 62.1 60.3 117 113
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 14.41 14.41 32.92 32.92
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 4.32 4.32 9.88 9.88
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 76.72 74.92 150.13 146.13
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 38.95 38.95 102.36 102.36
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 7.88 7.88 24.13 24.13
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-24
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇ ËÅÃÊÎÁÅÒÎÍÍÛÕ ÏËÈÒ Â
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦1 ÑËÎÉ ¦2 ÑËÎß
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-24-5 ¦ 8-24-6 ¦ 8-24-7 ¦ 8-24-8
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 80 77.6 152 147
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 4.16 4.16 8.39 8.39
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 12.62 12.62 25.45 25.45
-----------------------------------------------------------------------------------------------------------------------------
ÏÎÊÎÂÊÈ ÈÇ ÊÂÀÄÐÀÒÍÛÕ ÇÀÃÎÒÎÂÎÊ 101-0782 Ò 0.008 0.008 0.008 0.008
ÌÀÑÑÎÉ, ÊÃ 1,8
ÁÐÓÑÊÈ ÎÁÐÅÇÍÛÅ ÄËÈÍÎÉ 4-6,5 Ì, 102-0025 Ì3 0.1 0.1 0.2 0.2
ØÈÐÈÍÎÉ 75-100 ÌÌ, ÒÎËÙÈÍÎÉ
40-75 ÌÌ III ÑÎÐÒÀ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.5 0.5 1.1 1.1
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
ÏËÈÒÛ ÒÎËÙÈÍÎÉ ÄÎ 100 ÌÌ (403-9094 ) Ì2 95 95 174 174
ÒÎËÜ ÒÂÊ-350 610-1070 Ì2 6 6 12 12
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03 0.03 0.03 0.03
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 59.7 57.9 116 112
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 12.62 12.62 25.45 25.45
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 3.79 3.79 7.64 7.64
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.21 0.21 0.21 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 72.53 70.73 141.66 137.66
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 17.72 17.72 31.42 31.42
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.95 1.95 3.5 3.5
ÒÀÁËÈÖÀ 8-25
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÂÛÐÀÂÍÈÂÀÍÈÅ ÃÎÒÎÂÎÃÎ ÎÑÍÎÂÀÍÈß ÍÀ ÐÀÑÒÂÎÐÅ. 02.ÓÑÒÀÂÍÎÊÀ ÁËÎÊÎÂ Ñ ÀÐÌÈÐÎÂÀÍÈÅÌ ÊËÀÄÊÈ.
03.ÐÀÑØÈÂÊÀ ØÂÎÂ (ÃÐÀÔÛ 1,2).
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÏÅÐÅÃÎÐÎÄÎÊ (ÇÀ ÂÛ×ÅÒÎÌ ÏÐÎÅÌÎÂ)
-----------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÓÑÒÀÍÎÂÊÀ ÏÅÐÅÃÎÐÎÄÎÊ ÈÇ ÑÒÅÊËßÍ-¦ÇÀÏÎËÍÅÍÈÅ ÏÐÎÅÌΠÑÒÅÊËßÍÍÛÌÈ
¦ ¦ ¦ÍÛÕ ÁËÎÊΠ¦ÁËÎÊÀÌÈ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ
¦ ¦ ¦--------------------------------------------------------------------
¦ ¦ ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì ¦ÄÎ 4 Ì ¦ÑÂ.4 Ì
¦ ¦ ¦--------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-25-1 ¦ 8-25-2 ¦ 8-25-3 ¦ 8-25-4
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 118 116 136 133
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 4.37 4.37 4.37 4.37
-----------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 13.27 13.27 13.27 13.27
-----------------------------------------------------------------------------------------------------------------------------
ÁËÎÊÈ ÑÒÅÊËßÍÍÛÅ ÏÓÑÒÎÒÅËÛÅ 101-0083 1000 ØÒ 2.6 2.6 2.6 2.6
ÁÅÑÖÂÅÒÍÛÅ ÐÀÇÌÅÐÎÌ 194Õ194Õ98 ÌÌ
ÏÐÎÊÀÒ ÄËß ÀÐÌÈÐÎÂÀÍÈß Æ/Á 101-1150 Ò 0.112 0.112 0.112 0.112
ÊÎÍÑÒÐÓÊÖÈÉ ÊÐÓÃËÛÉ È
ÏÅÐÈÎÄÈ×ÅÑÊÎÃÎ ÏÐÎÔÈËß,
ÃÎÐß×ÅÊÀÒÀÍÛÉ È ÒÅÐÌÎÌÅÕÀÍÈ×ÅÑÊÈÉ,
ÒÅÐÌÈ×ÅÑÊÈ ÓÏÐÎ×ÅÍÍÛÉ ÊËÀÑÑ À-I,
ÄÈÀÌÅÒÐÎÌ 10 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0012 ) Ì3 0.74 0.74 0.74 0.74
ÖÅÌÅÍÒÍ0-ÈÇÂÅÑÒÊÎÂÛÅ ÌÀÐÊÈ 25
-----------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 83 81.6 98.8 96.6
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 13.27 13.27 13.27 13.27
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 3.98 3.98 3.98 3.98
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 96.27 94.87 112.07 109.87
-----------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 1492.16 1492.16 1492.16 1492.16
ÏÐÈÌÅÍßÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 102.48 102.48 102.48 102.48
13 ÏËÈÒÛ ÆÅËÅÇÎÁÅÒÎÍÍÛÅ ÏÎÄÎÊÎÍÍÛÅ
ÒÀÁËÈÖÀ 8-26 ÓÊËÀÄÊÀ ÏÎÄÎÊÎÍÍÛÕ ÆÅËÅÇÎÁÅÒÎÍÍÛÕ ÏËÈÒ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÓÊËÀÄÊÀ ÏËÈÒ Ñ ÏÎÄËÈÂÊÎÉ ÐÀÑÒÂÎÐÀ, ÏÎÄÃÎÍÊÎÉ ÏËÈÒ ÏÎ ÌÅÑÒÓ È ÇÀÄÅËÊÎÉ ØÂÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÏËÈÒ (Â ÄÅËÅ)
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Ñ ÌÎÇÀÈ×ÍÛÌ ÏÎÊÐÛÒÈÅÌ ¦ÃËÀÄÊÈÕ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-26-1 ¦ 8-26-2
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 115 98
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 4.37 4.31
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 13.27 13.06
-------------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÎÒÄÅËÎ×ÍÛÅ (402-0036 ) Ì3 3.06 3.06
Ò߯ÅËÛÅ ÖÅÌÅÍÒÍÛÅ ÑÎÑÒÀÂÀ 1:3
ÏËÈÒÛ ÏÎÄÎÊÎÍÍÛÅ ÆÅËÅÇÎÁÅÒÎÍÍÛÅ (440-9007Á) Ì2 102 102
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 2.5 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.38 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 81.3 70.1
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 13.27 13.06
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 3.98 3.92
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 2.5 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 97.07 83.37
14 ÊÐÛËÜÖÀ
ÒÀÁËÈÖÀ 8-27 ÓÑÒÐÎÉÑÒÂÎ ÊÐÛËÅÖ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÂÛÅÌÊÀ ÃÐÓÍÒÀ Ñ ÎÁÐÀÒÍÎÉ ÇÀÑÛÏÊÎÉ ÇÀ ÔÓÍÄÀÌÅÍÒÛ È ÎÒÂÎÇÊÎÉ ËÈØÍÅÃÎ ÃÐÓÍÒÀ. 02.ÊËÀÄÊÀ ÁÎÐÒÎÂÛÕ
ÑÒÅÍÎÊ Ñ ÎØÒÓÊÀÒÓÐÈÂÀÍÈÅÌ È ÎÊÐÀÑÊÎÉ (ÃÐÀÔÀ 2). 03.ÊËÀÄÊÀ ÔÓÍÄÀÌÅÍÒÎÂ È ÑÒÅÍÎÊ (ÃÐÀÔÀ 3). 04.ÓÊËÀÄÊÀ
ÁÅÒÎÍÍÎÉ ÏÎÄÃÎÒÎÂÊÈ È ÏËÎÙÀÄÎ×ÍÛÕ ÏËÈÒ. 05.ÓÊËÀÄÊÀ ÑÒÓÏÅÍÅÉ (ÃÐÀÔÛ 2-3). 06.ÓÑÒÐÎÉÑÒÂÎ ÀÑÔÀËÜÒÎÂÎÃÎ
ÏÎÊÐÛÒÈß.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì2 ÊÐÛËÜÖÀ
------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Ñ ÂÕÎÄÍÎÉ ÏËÎÙÀÄÊÎÉ ¦Ñ ÂÕÎÄÎÌ Ñ ÎÄÍÎÉ ÑÒÎÐÎ¦Ñ ÂÕÎÄÎÌ Ñ ÒÐÅÕ ÑÒÎÐÎÍ
¦ ¦ ¦ ¦ÍÛ Â ÎÄÍÓ ÑÒÓÏÅÍÜ ¦  ÒÐÈ ÑÒÓÏÅÍÈ
¦ ¦ ¦---------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-27-1 ¦ 8-27-2 ¦ 8-27-3
------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 1.53 2.86 11.2
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.13 0.13 0.36
------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.39 0.39 1.1
------------------------------------------------------------------------------------------------------------------------------
ÁÅÒÎÍ Ò߯ÅËÛÉ (ÊÐÎÌÅ ÄÎÐÎÆÍÎÃÎ) (401-0035 ) Ì3 0.05 0.09
ÌÀÐÊÈ 100 ÌÐÇ 50
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0002 ) Ì3 0.01 0.01 0.26
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 50
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.002 0.14
ÊÀÌÅÍÜ ÁÓÒÎÂÛÉ (408-9011 ) Ì3 0.44
ÏËÈÒÛ Æ/Á (440-9009 ) Ì3 Ï Ï Ï
ÑÒÓÏÅÍÈ ÆÅËÅÇÎÁÅÒÎÍÍÛÅ (440-9043 ) Ì Ï Ï Ï
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 2.05 2.79 0.56
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.31 0.42 0.08
------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 1.02 1.8 7.23
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.39 0.39 1.1
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.12 0.12 0.33
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 2.05 2.79 0.56
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 3.46 4.98 8.89
15 ÌÓÑÎÐÎÏÐÎÂÎÄ ÑÎ ÑÒÂÎËÎÌ ÈÇ ÀÑÁÅÑÒÎÖÅÌÅÍÒÍÛÕ ÒÐÓÁ
ÒÀÁËÈÖÀ 8-28 ÌÎÍÒÀÆ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÑÎ ÑÒÂÎËÎÌ ÈÇ ÀÑÁÎÖÅÌÅÍÒÍÛÕ ÒÐÓÁ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÓÑÒÀÍÎÂÊÀ ÂÅÐÒÈÊÀËÜÍÎÃÎ ÑÒÂÎËÀ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÈÇ ÀÑÁÅÑÒÎÖÅÌÅÍÒÍÛÕ ÒÐÓÁ ÄÈÀÌÅÒÐÎÌ 400 ÌÌ Ñ
ÍÀÄÂÈÆÍÛÌÈ ÌÓÔÒÀÌÈ, ÊÐÅÏËÅÍÈÅÌ ÑÒÂÎËÀ  ÏÐÅÄÅËÀÕ ÝÒÀÆÅÉ È ÍÈÆÍÅÉ ×ÀÑÒÈ ÑÒÂÎËÀ Ê ÑÒÀËÜÍÎÉ ÎÏÎÐÍÎÉ ÐÀÌÅ.
02.ÌÎÍÒÀÆ ÏÐÈÅÌÍÛÕ ÊËÀÏÀÍÎÂ Ñ ÂÛÐÅÇÊÎÉ ÎÒÂÅÐÑÒÈÉ Â ÀÑÁÎÖÅÌÅÍÒÍÛÕ ÒÐÓÁÀÕ ÏÎ ØÀÁËÎÍÓ, ÊÐÅÏËÅÍÈÅÌ ÊÎÆÓÕÀ
ÏÐÈÅÌÍÛÕ ÊËÀÏÀÍÎÂ Ê ÑÒÂÎËÓ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÕÎÌÓÒÀÌÈ ÍÀ ÓÏÐÓÃÈÕ ÏÐÎÊËÀÄÊÀÕ, Ñ ÃÅÐÌÅÒÈÇÀÖÈÅÉ ÑÎÏÐ߯ÅÍÈÉ.
03.ÓÑÒÀÍÎÂÊÀ ÄÅÒÀËÅÉ ÌÓÑÎÐÎÏÐÎÂÎÄÀ: ÂÛÒ߯ÍÎÉ ÒÐÓÁÛ Ñ ÄÈÔËÅÊÒÎÐÎÌ, ÒÅËÅÑÊÎÏÈ×ÅÑÊÎÃÎ ÎÒÂÎÄÀ Ñ ØÈÁÅÐÎÌ Ñ
ÃÅÐÌÅÒÈ×ÅÑÊÎÉ ÇÀÄÅËÊÎÉ ÏÐÈ ÑÎÅÄÈÍÅÍÈÈ ÑÒÂÎËÀ ÌÓÑÎÐÎÏÐÎÂÎÄÀ Ñ ÒÅËÅÑÊÎÏÈ×ÅÑÊÈÌ ÎÒÂÎÄÎÌ, ÌÓÑÎÐÎÑÁÎÐÍÈÊÀ
ÅÌÊÎÑÒÜÞ 750 Ë ÍÀ ÌÅÒÀËËÈ×ÅÑÊÎÉ ÒÅËÅÆÊÅ. 04.ÇÀÄÅËÊÀ ÌÅÑÒ ÏÐÎÕÎÄÀ ÑÒÂÎËÀ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ×ÅÐÅÇ ÏÅÐÅÊÐÛÒÈß
È ÏÎÊÐÛÒÈÅ ÐÀÑÒÂÎÐÎÌ È ÌÈÍÅÐÀËÜÍÎÉ ÂÀÒÎÉ. 05.ÎÊÐÀÑÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÄÅÒÀËÅÉ ÌÓÑÎÐÎÏÐÎÂÎÄÀ.
ÈÇÌÅÐÈÒÅËÜ: 1 ÌÓÑÎÐÎÏÐÎÂÎÄ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Â 9-ÝÒÀÆÍÛÕ ÇÄÀÍÈßÕ Ñ ÏßÒÜÞ ÊËÀÏÀÍÀÌÈ ÎÁÙÅÉ ÂÛÑÎÒÎÉ 25 Ì
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-28-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 61.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 12.56
-------------------------------------------------------------------------------------------------------------------------------
ÊÐÀÍÛ ÁÀØÅÍÍÛÅ ÏÐÈ ÐÀÁÎÒÅ ÍÀ 020129 Ì-×ÀÑ 10.4
ÄÐÓÃÈÕ ÂÈÄÀÕ ÑÒÐÎÈÒÅËÜÑÒÂÀ 8 Ò
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 6.56
-------------------------------------------------------------------------------------------------------------------------------
ÁÅËÈËÀ ÃÓÑÒÎÒÅÐÒÛÅ ÖÈÍÊÎÂÛÅ: 101-0384 Ò 0.002
ÌÀ-011-1
ÎËÈÔÀ ÊÎÌÁÈÍÈÐÎÂÀÍÍÀß: Ê-2 101-0627 Ò 0.0017
ÌÅÒÀËÈ×ÅÑÊÈÉ ÌÓÑÎÐÎÑÁÎÐÍÈÊ Ñ (101-9810 ) ÊÎÌÏË 1
ÒÅËÅÆÊÎÉ
ÒÐÓÁÛ ÁÅÇÍÀÏÎÐÍÛÅ (ÃÎÑÒ 1839-80) 103-0700 Ì 4
ÓÑËÎÂÍÛÉ ÏÐÎÕÎÄ 300 ÌÌ, ÂÍÓÒÐÅÍÍÈÉ
ÄÈÀÌÅÒÐ 279 ÌÌ
ÒÐÓÁÛ ÁÅÇÍÀÏÎÐÍÛÅ (ÃÎÑÒ 1839-80) 103-0701 Ì 24.5
ÓÑËÎÂÍÛÉ ÏÐÎÕÎÄ 400 ÌÌ, ÂÍÓÒÐÅÍÍÈÉ
ÄÈÀÌÅÒÐ 368 ÌÌ
ÌÅÒÀËËÎÊÎÍÑÒÐÓÊÖÈÈ ÎÏÎÐÍÎÉ ÐÀÌÛ ÈÇ (201-9017 ) ÊÃ 86
ÖÈËÈÍÄÐÈ×ÅÑÊÎÃÎ ÒÅËÅÑÊÎÏÈ×ÅÑÊÎÃÎ
ÎÒÂÎÄÀ
ÊËÀÏÀÍÛ ÏÐÈÅÌÍÛÅ (300-9173 ) ØÒ 5
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0002 ) Ì3 0.12
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 50
ÄÅÔËÅÊÒÎÐÛ ÂÛÒ߯ÍÛÅ ÖÈËÈÍÄÐÈ×ÅÑÊÈÅ 630-0195 ØÒ 1
ÒÈÏÀ ÖÀÃÈ ÈÇ ËÈÑÒÎÂÎÉ È ÑÎÐÒÎÂÎÉ
ÑÒÀËÈ, Â ÑÎÁÐÀÍÍÎÌ ÂÈÄÅ. ÄÈÀÌÅÒÐ
ÏÀÒÐÓÁÊÀ Â ÌÌ-ÄÏ, N ÄÈÔËÅÊÒÎÐÀ-NÄ
ÄÏ-280, NÄ-3
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 42.53
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 6.38
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË.8-28
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Â 9-ÝÒÀÆÍÛÕ ÇÄÀÍÈßÕ Ñ ÏßÒÜÞ ÊËÀÏÀÍÀÌÈ ÎÁÙÅÉ ÂÛÑÎÒÎÉ 25 Ì
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-28-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 43.7
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 80.82
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 14.03
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 42.53
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 167.05
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 178.53
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÅ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 26.59
ÒÀÁËÈÖÀ 8-29 ÍÀ ÊÀÆÄÛÉ ÝÒÀÆ ÑÂÅÐÕ ÈËÈ ÌÅÍÅÅ ÄÅÂßÒÈ ÄÎÁÀÂËßÒÜ ÈËÈ ÈÑÊËÞ×ÀÒÜ
ÈÇÌÅÐÈÒÅËÜ: 1 ÝÒÀÆ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-29-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.04
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 1.23
-------------------------------------------------------------------------------------------------------------------------------
ÊÐÀÍÛ ÁÀØÅÍÍÛÅ ÏÐÈ ÐÀÁÎÒÅ ÍÀ 020129 Ì-×ÀÑ 1.03
ÄÐÓÃÈÕ ÂÈÄÀÕ ÑÒÐÎÈÒÅËÜÑÒÂÀ 8 Ò
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.62
-------------------------------------------------------------------------------------------------------------------------------
ÁÅËÈËÀ ÃÓÑÒÎÒÅÐÒÛÅ ÖÈÍÊÎÂÛÅ: 101-0384 Ò 0.00012
ÌÀ-011-1
ÎËÈÔÀ ÊÎÌÁÈÍÈÐÎÂÀÍÍÀß: Ê-2 101-0627 Ò 0.0001
ÒÐÓÁÛ ÁÅÇÍÀÏÎÐÍÛÅ (ÃÎÑÒ 1839-80) 103-0701 Ì 2.86
ÓÑËÎÂÍÛÉ ÏÐÎÕÎÄ 400 ÌÌ, ÂÍÓÒÐÅÍÍÈÉ
ÄÈÀÌÅÒÐ 368 ÌÌ
ÊËÀÏÀÍÛ ÏÐÈÅÌÍÛÅ (300-9173 ) ØÒ 0.5
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0002 ) Ì3 0.01
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 50
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 3.03
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.45
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.54
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 7.97
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 1.38
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 3.03
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 14.54
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 17.34
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 2.58
--------------------------------------------------------------------------------------------------------------------------------
ÒÀÁËÈÖÀ 8-30 ÍÀ 1 Ì ÓÄËÈÍÅÍÈß ÑÒÂÎËÀ ÌÓÑÎÐÎÏÐÎÂÎÄÀ ÏÐÈ ÂÛÑÎÒÅ ÝÒÀÆÀ ÁÎËÅÅ 2,8 Ì ÄÎÁÀÂËßÒÜ ÈËÈ ÈÑÊËÞ×ÀÒÜ
ÈÇÌÅÐÈÒÅËÜ: 1 Ì ÑÒÂÎËÀ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-30-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 1.17
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.43
-------------------------------------------------------------------------------------------------------------------------------
ÊÐÀÍÛ ÁÀØÅÍÍÛÅ ÏÐÈ ÐÀÁÎÒÅ ÍÀ 020129 Ì-×ÀÑ 0.37
ÄÐÓÃÈÕ ÂÈÄÀÕ ÑÒÐÎÈÒÅËÜÑÒÂÀ 8 Ò
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.18
-------------------------------------------------------------------------------------------------------------------------------
ÒÐÓÁÛ ÁÅÇÍÀÏÎÐÍÛÅ (ÃÎÑÒ 1839-80) 103-0701 Ì 1.02
ÓÑËÎÂÍÛÉ ÏÐÎÕÎÄ 400 ÌÌ, ÂÍÓÒÐÅÍÍÈÉ
ÄÈÀÌÅÒÐ 368 ÌÌ
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 0.8
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.82
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.48
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 3.62
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.07
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÅ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.91
ÒÀÁËÈÖÀ 8-31 ÄÎÁÀÂËßÒÜ ÍÀ ÎÄÈÍ ÄÎÏÎËÍÈÒÅËÜÍÛÉ ÏÐÈÅÌÍÛÉ ÊËÀÏÀÍ
ÈÇÌÅÐÈÒÅËÜ: 1 ÏÐÈÅÌÍÛÉ ÊËÀÏÀÍ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-31-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 2.54
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.09
-------------------------------------------------------------------------------------------------------------------------------
ÁÅËÈËÀ ÃÓÑÒÎÒÅÐÒÛÅ ÖÈÍÊÎÂÛÅ: 101-0384 Ò 0.00024
ÌÀ-011-1
ÎËÈÔÀ ÊÎÌÁÈÍÈÐÎÂÀÍÍÀß: Ê-2 101-0627 Ò 0.0002
ÊËÀÏÀÍÛ ÏÐÈÅÌÍÛÅ (300-9173 ) ØÒ 1
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.07
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 1.83
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.09
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.03
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.07
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 1.99
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 0.64
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05
ÒÀÁËÈÖÀ 8-32 ÎÊÐÀÑÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÄÅÒÀËÅÉ ÌÓÑÎÐÎÏÐÎÂÎÄÀ
ÈÇÌÅÐÈÒÅËÜ: 1 ÌÓÑÎÐÎÏÐÎÂÎÄ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Â 9-ÝÒÀÆÍÛÕ ÇÄÀÍÈßÕ Ñ ÏßÒÜÞ ÊËÀÏÀÍÀÌÈ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-32-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 4.79
-------------------------------------------------------------------------------------------------------------------------------
ÁÅËÈËÀ ÃÓÑÒÎÒÅÐÒÛÅ ÖÈÍÊÎÂÛÅ: 101-0384 Ò 0.002
ÌÀ-011-1
ÎËÈÔÀ ÊÎÌÁÈÍÈÐÎÂÀÍÍÀß: Ê-2 101-0627 Ò 0.0017
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.62
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.09
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 3.78
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.62
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 4.4
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 5.38
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.47
ÒÀÁËÈÖÀ 8-33 ÏÐÈ ÎÊÐÀÑÊÅ ÍÀ ÊÀÆÄÛÉ ÝÒÀÆ ÑÂÅÐÕ ÈËÈ ÌÅÍÅÅ ÄÅÂßÒÈ ÄÎÁÀÂËßÒÜ ÈËÈ ÈÑÊËÞ×ÀÒÜ
ÈÇÌÅÐÈÒÅËÜ: 1 ÝÒÀÆ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-33-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 0.3
-------------------------------------------------------------------------------------------------------------------------------
ÁÅËÈËÀ ÃÓÑÒÎÒÅÐÒÛÅ ÖÈÍÊÎÂÛÅ: 101-0384 Ò 0.00012
ÌÀ-011-1
ÎËÈÔÀ ÊÎÌÁÈÍÈÐÎÂÀÍÍÀß: Ê-2 101-0627 Ò 0.0001
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.04
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 0.23
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.04
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 0.27
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 0.32
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.03
ÒÀÁËÈÖÀ 8-34 ÏÐÈ ÎÊÐÀÑÊÅ ÍÀ ÎÄÈÍ ÄÎÏÎËÍÈÒÅËÜÍÛÉ ÊËÀÏÀÍ ÄÎÁÀÂËßÒÜ
ÈÇÌÅÐÈÒÅËÜ: 1 ÏÐÈÅÌÍÛÉ ÊËÀÏÀÍ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-34-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 0.58
-------------------------------------------------------------------------------------------------------------------------------
ÁÅËÈËÀ ÃÓÑÒÎÒÅÐÒÛÅ ÖÈÍÊÎÂÛÅ: 101-0384 Ò 0.00024
ÌÀ-011-1
ÎËÈÔÀ ÊÎÌÁÈÍÈÐÎÂÀÍÍÀß: Ê-2 101-0627 Ò 0.0002
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.07
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.01
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 0.45
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.07
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 0.52
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 0.64
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05
16 ÍÀÐÓÆÍÛÅ È ÂÍÓÒÐÅÍÍÈÅ ËÅÑÀ
ÒÀÁËÈÖÀ 8-35 ÓÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÈÍÂÅÍÒÀÐÍÛÕ ËÅÑÎÂ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÏËÀÍÈÐÎÂÊÀ ÌÅÑÒÀ ÓÑÒÀÍÎÂÊÈ ÍÀÐÓÆÍÛÕ ËÅÑÎÂ (ÃÐÀÔÛ 1-3). 02.ÑÁÎÐÊÀ È ÓÑÒÀÍÎÂÊÀ ÈÍÂÅÍÒÀÐÍÛÕ ËÅÑÎÂ Ñ
ÓÑÒÐÎÉÑÒÂÎÌ ÍÀÑÒÈËÎÂ, ÎÃÐÀÆÄÅÍÈÉ, ÑÒÐÅÌßÍÎÊ È ÕÎÄÎÂÛÕ ËÅÑÒÍÈÖ. 03.ÐÀÇÁÎÐÊÀ ËÅÑÎÂ. 04.ÂÎÑÑÒÀÍÎÂÈÒÅËÜÍÛÉ
ÐÅÌÎÍÒ ÄÅÒÀËÅÉ ËÅÑÎÂ ÏÐÈ ÊÀÆÄÎÌ ÎÁÎÐÎÒÅ ÈÕ. 05.ÇÀÂÎÇÊÀ ÃÎÒÎÂÛÕ ÝËÅÌÅÍÒÎÂ ËÅÑÎÂ ÑÎ ÑÊËÀÄÀ ÍÀ ÎÁÚÅÊÒ È
ÎÒÂÎÇÊÀ ÈÕ ÏÎÑËÅ ÐÀÇÁÎÐÊÈ ÍÀ ÑÊËÀÄ ÈËÈ ÄÐÓÃÎÉ ÎÁÚÅÊÒ.
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÂÅÐÒÈÊÀËÜÍÎÉ ÏÐÎÅÊÖÈÈ ÄËß ÍÀÐÓÆÍÛÕ ËÅÑÎÂ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÍÀÐÓÆÍÛÕ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÂÛÑÎÒÎÉ ÄÎ 16 Ì ¦ÍÀ ÊÀÆÄÛÅ ÏÎÑËÅÄÓÞÙÈÅ 4 Ì
¦ ¦ ¦-----------------------------------------¦ÂÛÑÎÒÛ ËÅÑΠÄÎÁÀÂËßÒÜ
¦ ¦ ¦ÒÐÓÁ×ÀÒÛÕ ÄËߦÒÐÓÁ×ÀÒÛÕ ÄËߦÏÎÄÂÅÑÍÛÕ ¦----------------------------
¦ ¦ ¦ÊËÀÄÊÈ ÎÁËÈ- ¦ ÏÐÎ×ÈÕ ÎÒÄÅ-¦ ¦ÒÐÓÁ×ÀÒÛÕ ¦ÏÎÄÂÅÑÍÛÕ
¦ ¦ ¦ÖÎÂÊÈ ¦ËÎ×ÍÛÕ ÐÀÁÎÒ ¦ ¦ ¦
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-35-1 ¦ 8-35-2 ¦ 8-35-3 ¦ 8-35-4 ¦ 8-35-5
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 43.4 43.5 65.2 6.6 9.79
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.11 0.11 0.12
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.34 0.34 0.37
-------------------------------------------------------------------------------------------------------------------------------
ÄÅÐÅÂßÍÍÛÅ ÄÅÒÀËÈ ËÅÑΠ(102-9084 ) Ì3 0.006 0.009 0.009
ÑÒÀËÜÍÛÅ ÄÅÒÀËÈ ËÅÑÎÂ (103-9231 ) Ò 0.037 0.035 0.044
ÙÈÒÛ ÍÀÑÒÈËÀ 620-2004 Ì2 1.2 3.4 1.9
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 30.6 30.7 46.1 4.66 6.93
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.34 0.34 0.37
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.1 0.1 0.11
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 30.94 31.04 46.47 4.66 6.93
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 6.94 19.65 10.98
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.04 2.95 1.65
ÒÀÁËÈÖÀ 8-36 ÓÑÒÀÍÎÂÊÀ È ÐÀÇÁÎÐÊÀ ÈÍÂÅÍÒÀÐÍÛÕ ËÅÑÎÂ
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2Ã ÃÎÐÈÇÎÍÒÀËÜÍÎÉ ÏÐÎÅÊÖÈÈ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÂÍÓÒÐÅÍÍÈÕ, ÒÐÓÁ×ÀÒÛÕ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÏÐÈ ÂÛÑÎÒÅ ÏÎÌÅÙÅÍÈÉ ÄÎ 6 Ì ¦ÍÀ ÊÀÆÄÛÅ ÏÎÑËÅÄÓÞÙÈÅ 4 Ì ÂÛÑÎÒÛ
¦ ¦ ¦ ¦ÏÎÌÅÙÅÍÈÉ ÄÎÁÀÂËßÒÜ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-36-1 ¦ 8-36-2
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 70.2 49.8
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.28 0.16
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.84 0.48
-------------------------------------------------------------------------------------------------------------------------------
ÄÅÐÅÂßÍÍÛÅ ÄÅÒÀËÈ ËÅÑΠ(102-9084 ) Ì3 0.008 0.008
ÑÒÀËÜÍÛÅ ÄÅÒÀËÈ ËÅÑÎÂ (103-9231 ) Ò 0.029 0.029
ÙÈÒÛ ÍÀÑÒÈËÀ 620-2004 Ì2 5.5 1.4
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 49.5 35.1
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.84 0.48
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.25 0.14
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 50.34 35.58
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 31.79 8.09
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 4.77 1.21
17 ÏÅ×È ÎÒÎÏÈÒÅËÜÍÛÅ È Î×ÀÃÈ
ÒÀÁËÈÖÀ 8-37 ÎÑÍÎÂÀÍÈß ÏÎÄ ÏÅ×È, Î×ÀÃÈ È ÒÐÓÁÛ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ  ÃÎÒÎÂÛÕ ÊÎÒËÎÂÀÍÀÕ ÎÑÍÎÂÀÍÈÉ ÈÇ ÁÓÒÎÂÎÃÎ ÊÀÌÍß ÈËÈ ÈÇ ÊÈÐÏÈ×À È ÏÎËÎÂÍßÊÀ (ÃÐÀÔÛ 1,2).
02.ÓÑÒÐÎÉÑÒÂÎ ÈÇÎËßÖÈÈ (ÃÐÀÔÛ 1,2).
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÎÑÍÎÂÀÍÈß
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Â ÍÈÆÍÈÕ ÝÒÀÆÀÕ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÁÓÒÎÂÛÅ ¦ÊÈÐÏÈ×ÍÛÅ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-37-1 ¦ 8-37-2
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 5.66 4.45
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.17 0.55
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.52 1.66
-------------------------------------------------------------------------------------------------------------------------------
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0001 ) Ì3 0.41 0.36
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.19
ÏÎËÎÂÍßÊ ÊÅÐÀÌÈ×ÅÑÊÎÃÎ ÊÈÐÏÈ×À (405-0003 ) Ì3 0.6
ÊÀÌÅÍÜ ÁÓÒÎÂÛÉ (408-9011 ) Ì3 1.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 4.32 3.25
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.52 1.66
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.16 0.5
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 4.84 4.91
ÒÀÁËÈÖÀ 8-38 ÎÑÍÎÂÀÍÈß ÏÎÄ ÏÅ×È, Î×ÀÃÈ È ÒÐÓÁÛ
ÑÎÑÒÀÂ ÐÀÁÎÒ: 01.ÓÑÒÐÎÉÑÒÂÎ ÎÑÍÎÂÀÍÈß Â ÂÅÐÕÍÈÕ ÝÒÀÆÀÕ.
ÈÇÌÅÐÈÒÅËÜ: 1 ÌÅÑÒÎ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦Â ÂÅÐÕÍÈÕ ÝÒÀÆÀÕ
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-38-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 3.76
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.07
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.21
-------------------------------------------------------------------------------------------------------------------------------
ÑÎÐÒÎÂÎÉ È ÔÀÑÎÍÍÛÉ ÃÎÐß×ÅÊÀÒÀÍÛÉ 101-1045 Ò 0.02
ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ ÓÃËÅÐÎÄÈÑÒÎÉ
ÎÁÛÊÍÎÂÅÍÍÎÃÎ ÊÀ×ÅÑÒÂÀ ÄÂÓÒÀÂÐÛ Ñ
ÏÀÐÀËËÅËÜÍÛÌÈ ÃÐÀÍßÌÈ ÏÎËÎÊ,
ÍÎÐÌÀËÜÍÛÅ 'Á' ÏÎËÓÑÏÎÊÎÉÍÀß,
N16-18
ÏÐÎÊÀÒ ÄËß ÀÐÌÈÐÎÂÀÍÈß Æ/Á 101-1150 Ò 0.03
ÊÎÍÑÒÐÓÊÖÈÉ ÊÐÓÃËÛÉ È
ÏÅÐÈÎÄÈ×ÅÑÊÎÃÎ ÏÐÎÔÈËß,
ÃÎÐß×ÅÊÀÒÀÍÛÉ È ÒÅÐÌÎÌÅÕÀÍÈ×ÅÑÊÈÉ,
ÒÅÐÌÈ×ÅÑÊÈ ÓÏÐÎ×ÅÍÍÛÉ ÊËÀÑÑ À-I,
ÄÈÀÌÅÒÐÎÌ 10 ÌÌ
ÐÀÑÒÂÎÐÛ ÃÎÒÎÂÛÅ ÊËÀÄÎ×ÍÛÅ Ò߯ÅËÛÅ (402-0001 ) Ì3 0.02
ÖÅÌÅÍÒÍÛÅ ÌÀÐÊÈ 25
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 0.006
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 1.66
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.25
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.35
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.21
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.06
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 1.66
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 4.22
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 11.14
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.16
ÒÀÁËÈÖÀ 8-39 ÊËÀÄÊÀ ÏÅ×ÅÉ, Î×ÀÃÎÂ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÏÅ×ÅÉ È Î×ÀÃÎÂ Ñ ÓÑÒÐÎÉÑÒÂÎÌ ÐÀÇÄÅËÎÊ È ÕÎËÎÄÍÛÕ ×ÅÒÂÅÐÒÅÉ. 02.ÓÑÒÀÍÎÂÊÀ ÏÐÈÁÎÐΠ(ÃÐ.1-10)
È ÌÅÒÀËËÈ×ÅÑÊÈÕ ÎÁÐÀÌËÅÍÈÉ-ÏÎßÑΠ(ÃÐ.5-10). 03.ÈÇÃÎÒÎÂËÅÍÈÅ È ÓÑÒÀÍÎÂÊÀ ÑÒÀËÜÍÎÃÎ ÔÓÒËßÐÀ (ÃÐ.2,4) È
ÑÒÀËÜÍÛÕ ÇÎÍÒΠ(ÃÐ.9,10). 04.ÏÐÈÃÎÒÎÂËÅÍÈÅ ÃËÈÍßÍÎÃÎ ÐÀÑÒÂÎÐÀ. 05.ÓÑÒÐÎÉÑÒÂÎ È ÐÀÇÁÎÐÊÀ ÏÎÄÌÎÑÒÅÉ,
ÊÐÓÆÀË È ÎÏÀËÓÁÊÈ. 06.ÏÐÈÑÎÅÄÈÍÅÍÈÅ Ê ÄÛÌÎÕÎÄÀÌ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ ÁÅÇ ÂÛ×ÅÒÀ ÏÓÑÒÎÒ
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÎÒÎÏÈÒÅËÜÍÛÕ ¦ÊÓÕÎÍÍÛÕ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦Ñ ÒÎÏÊÎÉ ÏÎÄ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÄÐÎÂÀ ¦ÓÃÎËÜ ¦ÄÐÎÂÀ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÍÅ ÎÁËÈÖÎÂÀÍ-¦Â ÑÒÀËÜÍÛÕ ¦ÍÅ ÎÁËÈÖÎÂÀÍ-¦Â ÑÒÀËÜÍÛÕ ¦ÁÅÇ ÙÈÒÊÀ
¦ ¦ ¦ÍÛÅ È ÍÅ ÎØÒÓ¦ÔÓÒËßÐÀÕ ¦ÍÛÅ È ÍÅ ÎØÒÓ¦ÔÓÒËßÐÀÕ ¦
¦ ¦ ¦ÊÀÒÓÐÅÍÍÛÅ ¦ ¦ÊÀÒÓÐÅÍÍÛÅ ¦ ¦
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-39-1 ¦ 8-39-2 ¦ 8-39-3 ¦ 8-39-4 ¦ 8-39-5
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 10.4 16.6 10.4 16.6 9.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.75 0.73 0.75 0.73 0.59
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.28 2.2 2.28 2.2 1.78
-------------------------------------------------------------------------------------------------------------------------------
ÑÎÐÒÎÂÎÉ È ÔÀÑÎÍÍÛÉ ÃÎÐß×ÅÊÀÒÀÍÛÉ 101-0975 Ò 0.001 0.001 0.001 0.001 0.021
ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ ÓÃËÅÐÎÄÈÑÒÎÉ ÎÁÛÊÍÎ-
ÂÅÍÍÎÃÎ ÊÀ×ÅÑÒÂÀ ÏÎËÎÑÎÂÎÉ, ÒÎËÙ.
10-75 ÌÌ ÏÐÈ ØÈÐ.100-200 ÌÌ ÑÒÀËÜ ÑÒ0
ÒÎÍÊÎËÈÑÒÎÂÎÉ ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ 101-1133 Ò 0.001 0.021 0.001 0.021 0.002
ÓÃËÅÐÎÄÈÑÒÎÉ ÎÁÛÊÍÎÂÅÍÍÎÃÎ ÊÀ×ÅÑÒÂÀ
È ÊÀ×ÅÑÒÂÅÍÍÎÉ ÃÎÐß×ÅÊÀÒÀÍÛÉ Ñ ÎÁÐÅÇ-
ÍÛÌÈ ÊÐÎÌÊÀÌÈ, ÒÎËÙ. 3,9 ÌÌ
ÏÎÐÎØÎÊ ØÀÌÎÒÍÛÉ (115-9093 ) Ò 0.02 0.02
ÃËÈÍÀ ÎÃÍÅÓÏÎÐÍÀß ÌÎËÎÒÀß (115-9094 ) Ò 0.21 0.01 0.22
ÊÈÐÏÈ× ÒÓÃÎÏËÀÂÊÈÉ (115-9096 ) Ò 1.26 1
ÊÈÐÏÈ× ØÀÌÎÒÍÛÉ (115-9097 ) Ò 0.3 0.3
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-0031 ) 1000ØÒ 0.53 0.06 0.44 0.06 0.35
ÏÐÈÁÎÐÛ ÏÅ×ÍÛÅ (404-9050 ) ÊÎÌÏË Ï Ï Ï Ï Ï
ÏÅÑÎÊ (408-9020 ) Ì3 0.19 0.09 0.18 0.08 0.11
ÃËÈÍÀ (411-0002 ) Ì3 0.28 0.02 0.26 0.1
ÂÎÉËÎÊ ÑÒÐÎÈÒÅËÜÍÛÉ 610-1004 Ò 0.007 0.003 0.007 0.003
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.62 0.42 0.62 0.42 0.21
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.09 0.06 0.09 0.06 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 7.5 12.6 7.5 12.6 6.8
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.28 2.2 2.28 2.2 1.78
 ÒÎÌ ×ÈÑËÅ ÇÀÐÏËÀÒÀ ÌÀØÈÍÈÑÒΠÐÓÁ 0.68 0.66 0.68 0.66 0.53
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.62 0.42 0.62 0.42 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 10.4 15.22 10.4 15.22 8.79
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 8.68 9.08 8.68 9.08 3.95
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.29 1.08 1.29 1.08 0.47
ÏÐÎÄÎËÆÅÍÈÅ ÒÀÁË. 8-39
-------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÊÓÕÎÍÍÛÕ ¦ÏÈÙÅÂÀÐÎ×ÍÛÕ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦Ñ ÒÎÏÊÎÉ ÏÎÄ
¦ ¦ ¦----------------------------------------------------------------------
¦ ¦ ¦ÄÐÎÂÀ ¦ÓÃÎËÜ ¦ÄÐÎÂÀ ¦ÓÃÎËÜ
¦ ¦ ¦-----------------------------------------¦ ¦
¦ ¦ ¦ÑÎ ÙÈÒÊÎÌ ¦ÁÅÇ ÙÈÒÊÀ ¦ÑÎ ÙÈÒÊÎÌ ¦ ¦
¦ ¦ ¦----------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-39-6 ¦ 8-39-7 ¦ 8-39-8 ¦ 8-39-9 ¦ 8-39-10
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 9 9.3 9 12.3 12.3
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.61 0.59 0.61 0.56 0.56
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 1.86 1.78 1.86 1.69 1.69
-------------------------------------------------------------------------------------------------------------------------------
ÑÎÐÒÎÂÎÉ È ÔÀÑÎÍÍÛÉ ÃÎÐß×ÅÊÀÒÀÍÛÉ 101-0975 Ò 0.008 0.021 0.008 0.021 0.021
ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ ÓÃËÅÐÎÄÈÑÒÎÉ
ÎÁÛÊÍÎÂÅÍÍÎÃÎ ÊÀ×ÅÑÒÂÀ ÏÎËÎÑÎÂÎÉ,
ÒÎËÙÈÍÎÉ 10-75 ÌÌ ÏÐÈ ØÈÐÈÍÅ
100-200 ÌÌ ÑÒÀËÜ ÑÒ0
ÒÎÍÊÎËÈÑÒÎÂÎÉ ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ 101-1133 Ò 0.001 0.002 0.001 0.008 0.008
ÓÃËÅÐÎÄÈÑÒÎÉ ÎÁÛÊÍÎÂÅÍÍÎÃÎ
ÊÀ×ÅÑÒÂÀ È ÊÀ×ÅÑÒÂÅÍÍÎÉ
ÃÎÐß×ÅÊÀÒÀÍÛÉ Ñ ÎÁÐÅÇÍÛÌÈ ÊÐÎÌÊÀÌÈ,
ÒÎËÙÈÍÎÉ 3,9 ÌÌ
ÏÎÐÎØÎÊ ØÀÌÎÒÍÛÉ (115-9093 ) Ò 0.02 0.02 0.02
ÃËÈÍÀ ÎÃÍÅÓÏÎÐÍÀß ÌÎËÎÒÀß (115-9094 ) Ò 0.01 0.01 0.01
ÊÈÐÏÈ× ØÀÌÎÒÍÛÉ (115-9097 ) Ò 0.3 0.3 0.3
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-0031 ) 1000ØÒ 0.38 0.26 0.29 0.34 0.25
ÏÐÈÁÎÐÛ ÏÅ×ÍÛÅ (404-9050 ) 1 ÊÎÌÏË Ï Ï Ï Ï Ï
ÏÅÑÎÊ (408-9020 ) Ì3 0.14 0.1 0.13 0.09 0.08
ÃËÈÍÀ (411-0002 ) Ì3 0.19 0.08 0.17 0.14 0.12
ÂÎÉËÎÊ ÑÒÐÎÈÒÅËÜÍÛÉ 610-1004 Ò 0.002 0.002
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.42 0.21 0.42 0.21 0.21
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.06 0.03 0.06 0.03 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 6.5 6.8 6.5 9.2 9.2
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 1.86 1.78 1.86 1.69 1.69
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.56 0.53 0.56 0.51 0.51
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 0.42 0.21 0.42 0.21 0.21
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 8.78 8.79 8.78 11.1 11.1
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 3.93 3.95 3.93 5.49 5.49
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.54 0.47 0.54 0.62 0.62
ÒÀÁËÈÖÀ 8-40 ÓÑÒÀÍÎÂÊÀ Î×ÀÃΠÌÅÒÀËËÈ×ÅÑÊÈÕ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÓÑÒÀÍÎÂÊÀ ÌÅÒÀËËÈ×ÅÑÊÈÕ ÏËÈÒ Ñ ÎÁÌÓÐÎÂÊÎÉ ÒÎÏÊÈ ÊÈÐÏÈ×ÎÌ. 02.ÏÐÈÃÎÒÎÂËÅÍÈÅ ÃËÈÍßÍÎÃÎ ÐÀÑÒÂÎÐÀ.
03.ÓÑÒÐÎÉÑÒÂÎ È ÐÀÇÁÎÐÊÀ ÏÎÄÌÎÑÒÅÉ, ÊÐÓÆÀË È ÎÏÀËÓÁÊÈ. 04.ÏÐÈÑÎÅÄÈÍÅÍÈÅ Ê ÄÛÌÎÕÎÄÀÌ.
ÈÇÌÅÐÈÒÅËÜ: 1 Î×ÀÃ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-40-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 3.7
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.1
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 0.3
-------------------------------------------------------------------------------------------------------------------------------
ÒÎÍÊÎËÈÑÒÎÂÎÉ ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ 101-1133 Ò 0.002
ÓÃËÅÐÎÄÈÑÒÎÉ ÎÁÛÊÍÎÂÅÍÍÎÃÎ
ÊÀ×ÅÑÒÂÀ È ÊÀ×ÅÑÒÂÅÍÍÎÉ
ÃÎÐß×ÅÊÀÒÀÍÛÉ Ñ ÎÁÐÅÇÍÛÌÈ ÊÐÎÌÊÀÌÈ,
ÒÎËÙÈÍÎÉ 3,9 ÌÌ
ÃËÈÍÀ ÎÃÍÅÓÏÎÐÍÀß ÌÎËÎÒÀß (115-9094 ) Ò 0.08
ÊÈÐÏÈ× ÒÓÃÎÏËÀÂÊÈÉ (115-9096 ) Ò 0.028
ÏËÈÒÛ ÏÅÐÅÍÎÑÍÛÅ ÌÅÒÀËËÈ×ÅÑÊÈÅ ÄËß (205-9001 ) ØÒ 1
Î×ÀÃÎÂ
ÏÐÈÁÎÐÛ ÏÅ×ÍÛÅ (404-9050 ) 1 ÊÎÌÏË Ï
ÏÅÑÎÊ (408-9020 ) Ì3 0.03
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 2.7
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 0.3
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.09
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 3
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 0.51
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.05
ÒÀÁËÈÖÀ 8-41 ÊËÀÄÊÀ ÄÛÌÎÂÛÕ ÊÈÐÏÈ×ÍÛÕ ÒÐÓÁ
ÑÎÑÒÀ ÐÀÁÎÒ: 01.ÊËÀÄÊÀ ÒÐÓÁ Ñ ÓÑÒÐÎÉÑÒÂÎÌ ÐÀÇÄÅËÎÊ, ÕÎËÎÄÍÛÕ ×ÅÒÂÅÐÒÅÉ. 02.ÓÑÒÐÎÉÑÒÂÎ È ÐÀÇÁÎÐÊÀ ÏÎÄÌÎÑÒÅÉ È
ÎÏÀËÓÁÊÈ. 03.ÓÑÒÀÍÎÂÊÀ ÑÒÀËÜÍÛÕ ÇÎÍÒÎÂ.
ÈÇÌÅÐÈÒÅËÜ: 1 Ì3 ÊËÀÄÊÈ ÁÅÇ ÂÛ×ÅÒÀ ÏÓÑÒÎÒ
-------------------------------------------------------------------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-41-1
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 11.9
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 0.7
-------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 2.11
-------------------------------------------------------------------------------------------------------------------------------
ÒÎÍÊÎËÈÑÒÎÂÎÉ ÏÐÎÊÀÒ ÈÇ ÑÒÀËÈ 101-1133 Ò 0.006
ÓÃËÅÐÎÄÈÑÒÎÉ ÎÁÛÊÍÎÂÅÍÍÎÃÎ
ÊÀ×ÅÑÒÂÀ È ÊÀ×ÅÑÒÂÅÍÍÎÉ
ÃÎÐß×ÅÊÀÒÀÍÛÉ Ñ ÎÁÐÅÇÍÛÌÈ ÊÐÎÌÊÀÌÈ,
ÒÎËÙÈÍÎÉ 3,9 ÌÌ
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-0031 ) 1000ØÒ 0.49
ÏÅÑÎÊ (408-9020 ) Ì3 0.08
ÃËÈÍÀ (411-0002 ) Ì3 0.12
ÂÎÉËÎÊ ÑÒÐÎÈÒÅËÜÍÛÉ 610-1004 Ò 0.003
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 1.46
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.22
-------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 8.6
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 2.11
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 0.63
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 1.46
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 12.17
-------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 5.08
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 0.68
ÒÀÁËÈÖÀ 8-42 ÎÒÄÅËÊÀ ÏÅ×ÅÉ
ÈÇÌÅÐÈÒÅËÜ: 100 Ì2 ÎÁËÈÖÎÂÀÍÍÎÉ ÈËÈ ÎØÒÓÊÀÒÓÐÅÍÍÎÉ ÏÎÂÅÐÕÍÎÑÒÈ
------------------------------------------------------------------------------------------------------------------------------
¦ ¦ ¦ÈÇÐÀÇÖÀÌÈ ¦ØÒÓÊÀÒÓÐÍÛÌ ÃËÈÍßÍÛÌ ÐÀÑÒÂÎÐÎÌ
¦ ¦ ¦ ¦----------------------------------------------
¦ ¦ ¦ ¦ÁÅÇ ÑÅÒÊÈ ¦ÏÎ ÑÅÒÊÅ
¦ ¦ ¦---------------------------------------------------------------------
ÍÀÈÌÅÍÎÂÀÍÈÅ ÝËÅÌÅÍÒÎÂ ÇÀÒÐÀÒ ¦ ÊÎÄ ¦ ÅÄ.ÈÇÌ. ¦ 8-42-1 ¦ 8-42-2 ¦ 8-42-3
------------------------------------------------------------------------------------------------------------------------------
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ×ÅË.-× 362 15 44
ÇÀÒÐÀÒÛ ÒÐÓÄÀ ÌÀØÈÍÈÑÒΠ×ÅË.-× 6.17 1.12 1.34
------------------------------------------------------------------------------------------------------------------------------
ÏÐÎ×ÈÅ ÌÀØÈÍÛ ÐÓÁ 18.73 3.41 4.06
------------------------------------------------------------------------------------------------------------------------------
ÏÐÎÂÎËÎÊÀ ÑÒÀËÜÍÀß 101-0811 Ò 0.071 0.001
ÍÈÇÊÎÓÃËÅÐÎÄÈÑÒÀß ÐÀÇÍÎÃÎ
ÍÀÇÍÀ×ÅÍÈß, ÎÖÈÍÊÎÂÀÍÍÀß ÄÈÀÌÅÒÐÎÌ,
ÌÌ: 1,1
ÑÅÒÊÀ ÏÐÎÂÎËÎ×ÍÀß ÏËÅÒÅÍÀß Ñ 101-0872 Ì2 108
ÊÂÀÄÐÀÒÍÛÌÈ ß×ÅÉÊÀÌÈ N12 ÁÅÇ
ÏÎÊÐÛÒÈß
ÏÎÐÒËÀÍÄÖÅÌÅÍÒ ÎÁÙÅÑÒÐÎÈÒÅËÜÍÎÃÎ 101-1315 Ò 0.2 0.2
ÍÀÇÍÀ×ÅÍÈß Ñ ÌÈÍÅÐÀËÜÍÛÌÈ
ÄÎÁÀÂÊÀÌÈ, ÌÀÐÊÈ: 300
ÈÇÐÀÇÖÛ ÐßÄÎÂÛÅ (101-9053 ) Ì2 84
ÈÇÐÀÇÖÛ ÔÀÑÎÍÍÛÅ (101-9054 ) Ì2 21
ÊÈÐÏÈ× ÊÅÐÀÌÈ×ÅÑÊÈÉ (404-9031 ) 1000ØÒ 1.5
ÏÅÑÎÊ (408-9020 ) Ì3 1.3 0.9 0.9
ÃËÈÍÀ (411-0002 ) Ì3 2.1 1.4 1.4
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 7.44 0.15 0.15
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 1.12 0.02 0.02
------------------------------------------------------------------------------------------------------------------------------
ÇÀÐÏËÀÒÀ ÐÀÁÎ×ÈÕ-ÑÒÐÎÈÒÅËÅÉ ÐÓÁ 326 10.5 30.8
ÝÊÑÏËÓÀÒÀÖÈß ÌÀØÈÍ ÐÓÁ 18.73 3.41 4.06
 ÒÎÌ ×ÈÑËÅ
ÇÀÐÀÁÎÒÍÀß ÏËÀÒÀ ÌÀØÈÍÈÑÒÎÂ ÐÓÁ 5.62 1.02 1.22
ÏÐÎ×ÈÅ ÌÀÒÅÐÈÀËÛ ÐÓÁ 7.44 0.15 0.15
ÂÑÅÃÎ, ÏÐßÌÛÅ ÇÀÒÐÀÒÛ ÐÓÁ 352.17 14.06 35.01
------------------------------------------------------------------------------------------------------------------------------
ÌÀÒÅÐÈÀËÜÍÛÅ ÐÅÑÓÐÑÛ (ÊÐÎÌÅ ÐÓÁ 44.02 7.88 191.02
ÏÐÈÍÈÌÀÅÌÛÕ ÏÎ ÏÐÎÅÊÒÓ,
ÎÒÌÅ×ÅÍÍÛÕ ÑÊÎÁÊÀÌÈ, È ÏÐÎ×ÈÕ)
 ÒÎÌ ×ÈÑËÅ
ÒÐÀÍÑÏÎÐÒÍÛÅ ÐÀÑÕÎÄÛ ÐÓÁ 2.91 2.98 14.9
|